scholarly journals Application of a non-contact three-dimensional laser morphological measuring system and milling machine to the production of maxillofacial prostheses. Siymplification of impression taking and wax-up.

2000 ◽  
Vol 46 (3) ◽  
pp. 169-171 ◽  
Author(s):  
Mitsuhiro TSUJI ◽  
Nobuhiro NOGUCHI ◽  
Koichiro IHARA ◽  
Masahito SHIGEMATSU ◽  
Masaaki GOTO ◽  
...  
2008 ◽  
Vol 580-582 ◽  
pp. 557-560 ◽  
Author(s):  
J.G. Han ◽  
Kyong Ho Chang ◽  
Gab Chul Jang ◽  
K.K. Hong ◽  
Sam Deok Cho ◽  
...  

Recently, in the loading tests for steel members, the deformation value is measured by calculating a distance of both cross-heads. This measuring method encounters a test error due to various environmental factors, such as initial slip, etc.. Especially, in the case of welded members, the non-uniform deformation behavior in welded joints is observed because of the effect of welding residual stress and weld metal. This is mainly responsible for a test error and a loss of the reliability for used test instruments. Therefore, to improve the accuracy and the applicability of measuring system, it is necessary to employ a visual monitoring system which can accurately measure the local and overall deformation of welded members. In this paper, to accurately measure a deformation of welded members, a visual monitoring system (VMS) was developed by using three-dimensional digital photogrammetry. The VMS was applied to the loading tests of a welded member. The accuracy and the applicability of VMS was verified by comparing to the deformation value measured by a test instrument (MTS-810). The characteristics of the behavior near a welded joint were investigated by using VMS.


2012 ◽  
Vol 429 ◽  
pp. 111-115
Author(s):  
Zhen Long Leng ◽  
Jin Feng Yang ◽  
Qun Ping Liu ◽  
Xun Deng

This paper focuses on application of the three-dimensional digital modeling, numerical analysis and optimization, digital control and other key technologies which provide technical support for the design and development in CNC floor boring and milling machine manufactruing. The three-dimensional digital modeling, digital assembly, interference checking help to eliminate some hidden trouble before processing and assembly. Numerical simulation reduces the cost and shortens the cycle of designand manufactruing in the optimal design of the machine. This technique has been successfully applied to a CNC Floor Boring and Milling Machine Model, which has been running for three years and achieved satisfactary economic result.


Author(s):  
Chao-Hwa Chang

Abstract The concept of mapping a three dimensional (3D) contouring cutter path with major motion in a plane parallel to the Z axis onto the X-Y plane or one perpendicular to the Z axis is introduced. A systematic method is developed that can be used to program, in APT or other high-level languages, complex contouring cutter motion based on the concept introduced. As a result, NC programming of contouring motion for many complex engineering parts on a 3-axis numerically controlled (NC) milling machine, which is often considered difficult, can be greatly simplified. Part examples are discussed; and the APT programs defining the cutter path based on the 3D-to-2D mapping concept, are also analyzed in detail. The concept and method introduced proved to be a powerful tool for programming the NC machining process for many parts, particularly dies and molds.


2012 ◽  
Vol 198-199 ◽  
pp. 1053-1056
Author(s):  
Liang Han ◽  
Jing Song Jin ◽  
Wei Zhang

Tennis is a very elegant sport, with a strong sense of competitiveness and appreciation, which has gained more and more attentions in our country, and it tends to be a fashion. This project is to achieve the measurement of tennis batting motion attitude in three dimensional space using a combination of the three-axis MEMS(Micro-electromechanical Systems) sensors, and make research on the principle of measurement system, composition and data acquisition. Body posture measurement system is to measure the attitude measurement in human movement, it can be applied to study the movement posture or to meet the requirements of position control, which provides theoretical foundation for scientific training and prevention of sports injury and also plays a significant and instructional role in improving the training levels of tennis playing and generalizing nationwide fitness campaign.


1996 ◽  
Vol 33 (3) ◽  
pp. 245-251 ◽  
Author(s):  
Katsuaki Mishima ◽  
Toshio Sugahara ◽  
Yoshihide Mori ◽  
Masayoshi Sakuda

A three-dimensional measuring system was developed to analyze changes in palatal forms of UCLP infants. This system quantified the change of the curved surface on a palate by automatically superimposing two wireframe models obtained from casts at different stages of growth. It also analyzed the curvature of the palatal surface. This system was used to study the palates of 20 infants with unilateral cleft lip and palate (UCLP), from the first to fourth months after birth (12 with Hotz's plate and 8 without, selected at random). Both major and lesser maxillary segments without Hotz's plate remained anterior and lateral although those with Hotz's plate moved mesially during the fourth month after birth. In addition, the degrees of curvature on the palatal surfaces with Hotz's plate were less than those without Hotz's plate.


Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2762 ◽  
Author(s):  
Ruimin Shi ◽  
Bukang Wang ◽  
Zhiwei Yan ◽  
Zongyan Wang ◽  
Lei Dong

In order to explore the relationship between the surface topography parameters and friction properties of a rough contact interface under fluid dynamic pressure lubrication conditions, friction experiments were carried out. The three-dimensional surface topography of specimens was measured and characterized with a profile microscopy measuring system and scanning electron microscope. The friction coefficient showed a trend of decreasing first and then increasing with the increase in some surface topography parameters at lower pressure, such as the surface height arithmetic mean Sa, surface height distribution kurtosis Sku, surface volume average volume Vvv, and surface center area average void volume Vvc, which are the ISO 25178 international standard parameters. The effects of surface topographic parameters on friction were analyzed and the wear mechanism of the worn surface was presented. The wear characteristics of the samples were mainly characterized as strain fatigue, grinding, and scraping. The results provide a theoretical basis for the functional characterization of surface topography.


1998 ◽  
Vol 102 (6) ◽  
pp. 2108-2113 ◽  
Author(s):  
Tomohiro Yamada ◽  
Toshio Sugahara ◽  
Yoshihide Mori ◽  
Masayosi Sakuda

Sign in / Sign up

Export Citation Format

Share Document