Development and Validation of Spectroscopic Simultaneous Equation Method for Simultaneous Estimation of Itopride Hydrochloride and Omeprazole in Synthetic Mixture

2019 ◽  
Vol 9 (4) ◽  
pp. 238
Author(s):  
Hiral J. Varachhiya ◽  
Rohan K. Barse ◽  
Suresh Jain
Author(s):  
Gaur A ◽  
Yashwant .

A new, rapid, precise, selective and sensitive Vierodt���s/simultaneous equation method is developed for the simultaneous estimation of pantoprazole (PNT) and cinitapride (CNT) in combined dosage form. In the developed method, absorbance was measured at 289 nm (�� max of Pantoprazole) and 267.2 nm (�� max of Cinitapride). The drugs obeyed the Beer���s law in the concentration range of 13-65��g/ml and 1-5 ��g/ml respectively for pantoprazole and cinitapride. Accuracy of the method was determined by recovery studies and was found to be 101.32 % and 98.9 % for Pantoprazole and Cinitapride respectively. The developed method is simple, precise, rapid and selective. It can be used for routine analysis of both drugs in bulk as well as in pharmaceutical formulations.


Author(s):  
Siva Kishore Masimukku ◽  
Rambabu Chintal

Objective:  To develop a simple, rapid,  precise, accurate, sensitive spectrophotometric methods (A&B) were developed for simultaneous estimation and validation of Vilanterol (VTL) and Fluticasone Furoate (FFE) in pure and tablet dosage forms.Method:   Method A is a simultaneous equation method and method B is a first order derivative spectrophotometric method. Pure drug samples of VTL and FFE were dissolved in a mixture of Methanol and Ethanol in the ratio of 1:1 (v/v) and found to have absorbance maxima at 231nm for VTL and 260nm for FFE respectivelyResults:  The linearity lies between 2.5–10µg/ml for VTL and 10–60µg/ml for FFE in these two methods (A&B).  The correlation coefficient (r2) was found to be 0.999 for both VTL and FFE, the limit of detection and limit of quantification were found to be 0.015µg/ml and 0.05µg/ml for VTL and 0.05µg/ml and 0.2µg/ml for FFE respectively. The results of analysis have been validated statistically by recovery studies as per ICH guidelines.Conclusion: The two methods A&B showed good reproducibility and recovery with % RSD less than 2.  Hence both methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of VTL and FFE in pure and combined dosage form.Keywords: Fluticasone furoate, Vilanterol, Derivative spectrophotometric, Simultaneous equation method, Method development and validation.


Author(s):  
Pratik S Mehta ◽  
Pratik R. Patel ◽  
Rajesh R Parmar ◽  
M M K Modasiya ◽  
Dushyant A Shah

A novel, simple, accurate, sensitive, precise and economical derivative spectroscopic method was developed and validated for the determination of cefadroxil and probenecid in synthetic mixture. First order derivative spectroscopy method was adopted to eliminate spectral interference. The method obeys Beer’s Law in concentration ranges of 4-36 μg/ml for cefadroxil and of 5-25 μg/ml of probenecid. The zero crossing point for cefadroxil and probenecid was 260 nm and 237.8 nm respectively in 0.1N HCl. The method was validated in terms of accuracy, precision, linearity, limits of detection, limits of quantitation. This method has been successively applied to synthetic mixture and no interference from the synthetic mixture’s excipients was found.   


2015 ◽  
Vol 1 (3) ◽  
pp. 151
Author(s):  
Sojitra Rajanit ◽  
Paras Virani ◽  
Hashumati Raj

A new simple, economical, precise and accurate method are described for the simultaneous determination of Nifedipine (NIF) and Metoprolol Succinate (MET) in combined tablet dosage form. The proposed method was applied for the determination of Nifedipine and Metoprolol Succinate in synthetic mixture, for determination of sampling wavelength, 10?g/ml of each of NIF and MET were scanned in 200-400 nm range and sampling wavelengths were 313nm for NIF and 275.40nm for MET are selected for development and validation of absorption correction method. For this method linearity observed in the range of 5-25?g/ml for NIF and 25-125?g/ml for MET, and in their pharmaceutical formulation with mean percentage recoveries 100.68 and 100.33, respectively. The method was validated according to ICH guidelines and can be applied for routine quality control testing.