scholarly journals Comparative Evaluation of the Dimensional Accuracy of Closed Tray and Open Tray Impression Technique for Dental Implants using Two Different Impression Materials

Author(s):  
Arpita Tandon ◽  
Nilesh S Bulbule ◽  
Amit K Jagtap ◽  
Dilip M Kakade
2019 ◽  
Vol 4 (2) ◽  
pp. 90-93
Author(s):  
Hussameldien Hussien ◽  
◽  
Natashekara Mallesh ◽  

Background of the study: Dental implants are one of the most sought-after choice of treatment for restoration and rehabilitation of missing teeth. However, the accuracy of the removable or fixed superstructures over the dental implants is influenced for a major proportion by the impression techniques and materials. This paper discusses the comparison of the accuracy of different impression materials and techniques used in the second stage of the dental implant treatment in vivo. Objective: The objective of the paper is to study the comparison of the accuracy of different impression materials and techniques used in the second stage of the dental implant’s treatment in vivo. Search methodology: Electronically key searched in scientific literature databases. Selection criteria: Based on the set inclusion and exclusion criteria such as studies conducted in partial edentulous arches, in the age group of 30 to 55 years. Data collection and analysis: A total of 248 literatures were found to be relevant to the framed topic and were scrutinised based on the dejected criteria and 18 kinds of literature obtained were taken into consideration. Main Result: Among the different impression materials taken into the comparative study, it was observed that polyvinyl siloxane exhibited a dimensional accuracy slightly greater than polyether. However, light body putty exhibited greater accuracy than medium body putty. Various impression techniques were compared to evaluate the dimensional accuracy of the impression. It was observed that the open tray technique and splinted impression technique produced a more dimensionally stable impression than the other techniques. Authors Conclusion: this study to assess the accuracy of various impression material and methods has concluded that while impression techniques influence the accuracy of the impression, the impression materials namely the Polyvinyl siloxane and polyether exhibit no significant difference with a slight preference to the polyvinyl siloxane. Hence the choice of impression material is at the discretion of the dentist performing the treatment and also this area requires further studies to establish conclusive evidence.


2016 ◽  
Vol 17 (9) ◽  
pp. 734-739
Author(s):  
Mohammed E Sayed ◽  
Bandar MA Al-Makramani ◽  
Fuad A Al-Sanabani ◽  
Mohamed S Mohamed

ABSTRACT Aim The aim of this study was to evaluate the effect of intermixing brands of addition silicone impression materials on the dimensional accuracy of stone models using two-step putty-wash technique. Materials and methods Two common brands of addition silicone impression material (Express and Aquasil) were used in this study. A total of 40 impressions of a stainless steel model simulating a three-unit bridge were made, 10 impressions for each group. Accuracy was assessed by measuring two dimensions (inter-abutment and intra-abutment) on stone models obtained from impressions of the stainless steel model. Each sample was measured thrice and the mean value was calculated. The data were analyzed using analysis of variance (ANOVA) and Scheffe's post hoc test. Results The results indicated that each of the inter-abutment and intra-abutment dimensions of the stone models was significantly higher than those for the stainless steel model (p < 0.001). However, there was no statistically significant difference in each of the inter-abutment and intra-abutment dimensions of the stone models among the four tested groups (p < 0.05). Conclusion The results obtained were statistically analyzed and the values of the inter-abutment and intra-abutment dimensions were all within the clinically acceptable range. Clinical significance Intermixing brands of additional silicone impression materials evaluated in this study did not affect the dimensional accuracy of obtained stone casts. This will help to minimize the wastage of materials due to lack of either light or putty consistency of the same brand of additional silicone impression material. How to cite this article Sayed ME, Al-Makramani BMA, Al-Sanabani FA, Mohamed MS. Effect of Intermixing Brands on the Dimensional Accuracy of Master Cast using Putty-wash Impression Technique. J Contemp Dent Pract 2016;17(9):734-739.


2017 ◽  
Vol 15 (3) ◽  
pp. 238
Author(s):  
Rafael Pino Vitti ◽  
Adriano Relvas Barreira de Oliveira ◽  
Mário Alexandre Coelho Sinhoreti

Aim: Evaluate the dimensional accuracy of stone casts of a partially edentulous mandibular arch made by two impression techniques (1-step putty/light-body and 2-step putty/light-body) using addition and condensation silicones. Methods: A partially edentulous steel stainless cast with four markings on teeth 33, 37, 43, and 47 was used to obtain the impressions. The transverse (33-43 and 37-47) and anteroposterior (33-37 and 43-47) distances were measured by measuring microscope (30x magnification; 0.5μm accuracy). For the 1-step putty/light-body technique, both viscosities of the impression materials were handled together. For the 2-step putty/light-body technique, the impression materials of different viscosities were handled separately and a polypropylene spacer (2 mm thick) was used to create a relief. The same distances were measured om stone casts (n = 5). The values were submitted to normality test (Kolmogorov-Smirnov) and analyzed statistically by three-way ANOVA and Tukey’s (5%). Results: All distances showed shrinkage (negative linear changes). The addition silicones showed better accuracy than condensation silicones (p<0.05) and no significant difference was found between the impression techniques (p>0.05). The edentulous zone (43-47) presented worst dimensional accuracy results. Conclusions: The accuracy of the castsis more related to the impression material than impression technique.


Author(s):  
Mahsa Abbasi ◽  
Behnaz Ebadian ◽  
Negin Aminianpour

Introduction: Digital impression tools are an alternative to old impression materials and have developed significantly in recent years. These systems generally include two types of scanners: direct and indirect scanners. This article aimed to review and compare these two types of scanners. Description: Data were collected by reviewing a total of forty articles on dimensional accuracy, a combination of scans, and internal and marginal gaps for comparison of direct and indirect scanners. These articles were retrieved from PubMed and Scopus and published between 2010 and 2020 using the following keywords: intraoral scanner, lab scanner, marginal gap, internal gap, and accuracy rate. Results: Direct scanners had a lower amount of marginal and internal gaps, while indirect scanners had a lower deviation in more prepared teeth in the half and full arch due to the ability of stitching scans. Regarding the dimensional accuracy, the results of studies were inconsistent, but clinical studies pointed to the superiority of indirect scanners. The type of scanner suggested being selected depending on conditions such as the size of area, time, convenience of procedure, etc. The clinical results of both types of scanners were clinically acceptable.


2021 ◽  
Author(s):  
Cheng Zhang ◽  
Zhaoliang Jiang ◽  
Li Zhao ◽  
Weiwei Guo ◽  
Chengpeng Zhang

Abstract Sintering process is essential to acquire the final components by stereolithography (SLA), which is a promising additive manufacturing technology for the fabrication of complex, custom-designed dental implants. 3Y-ZrO2 ceramics at different sintering behaviors in air atmosphere were successfully obtained in this study. Firstly, the curing properties of homemade pastes were studied, and the penetration depth and critical exposure of the pastes were calculated as 17.2 μm and 4.80 mJ/cm2, respectively. The green ceramic parts were performed at 154 mW laser power and 6000 mm/s scanning speed. Then, the dimensional accuracy, surface quality, and mechanical properties of 3Y-ZrO2 ceramics were investigated. The shrinkages of length, width, and height were 26%~27 %, 30%~31 %, and 27%~33 % in sintered ceramics, respectively. The Ra values of XOY, YOZ, and XOZ surfaces showed an anisotropic feature, and they were smallest as 0.52 μm, 2.40 μm, and 2.46 μm, respectively. Meanwhile, the mechanical properties presented a similar trend that they grew first and then dropped at various sintering behaviors. The optimal parameters were 1500 ℃, 60 min, and 4 ℃/min, and the maximum relative density of 96.18 %, Vickers hardness of 12.45 GPa, and fracture toughness of 6.35 MPa·m1/2 were achieved. Finally, the X-ray diffraction (XRD) and energy-dispersive spectroscopy (EDS) analysis demonstrated that no change was observed in crystal transformation and phase composition, and the organic was completely removed in sintered ceramics. This research is expected to provide a technical guide for the fabrication of ceramics for dental implants using SLA technique.


2013 ◽  
Vol 14 (2) ◽  
pp. 265-268 ◽  
Author(s):  
Naveen S Yadav ◽  
Teerthesh Jain ◽  
Amrita Pandita ◽  
SMA Feroz ◽  
Pradeep LNU ◽  
...  

ABSTRACT Aim Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. Materials and methods In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. Results Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. Conclusion All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. Clinical significance In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions. How to cite this article Pandita A, Jain T, Yadav NS, Feroz SMA, Pradeep, Diwedi A. Evaluation and Comparison of Dimensional Accuracy of Newly Introduced Elastomeric Impression Material using 3D Laser Scanners: An in vitro Study. J Contemp Dent Pract 2013;14(2):265-268.


Sign in / Sign up

Export Citation Format

Share Document