Determining the Impact of Pre-Operative Computed Tomography Scan in Patients Underwent Septoplasty on the Postoperative Complications

Author(s):  
Abdulwahid S. AlQahtani ◽  
Ramzi M. Dagriri ◽  
Radeif E. Shamakhi ◽  
Ahmad M. Alrasheed ◽  
Ahmed A. Etwadi ◽  
...  
Author(s):  
Abdulwahid S. AlQahtani ◽  
Ramzi M. Dagriri ◽  
Radeif E. Shamakhi ◽  
Ahmad M. Alrasheed ◽  
Ahmed A. Etwadi ◽  
...  

<p class="abstract"><strong>Background:</strong> Deviated nasal septum (DNS) is one of the most frequent causes of nasal obstruction in adults. An anterior rhinoscopy (AR), which is usually the first diagnostic procedure in the evaluation of obstructive nasal pathologies, is often inadequate in the assessment of the posterior nasal cavity and the gold standard method for the evaluation of paranasal anatomy and inflammatory paranasal sinus pathologies is paranasal sinus computed tomography (PNS CT). Aim was to validate the recommendation of pre-operative computed tomography scan in minimizing post-septoplasty complications.</p><p class="abstract"><strong>Methods:</strong> A retrospective record based study was conducted including all patients with clinically diagnosed DNS and undergone surgical intervention at Khamis Mushayet General Hospital. Data extracted included patients demographic data, and post-operative recorded complications and history of preoperative CT scan for evaluating and grading DNS.  </p><p class="abstract"><strong>Results:</strong> A total sample of 60 patients’ undergone septoplasty for DNS. Patients who undergone preoperative CT were 30. The remaining 30 patients didn’t undergone pre-operative CT for evaluation of DNS. The most diagnosed complication was nasal obstruction (28.3%) followed by external nose deformity (20%). Exact of 47% of patients had postoperative nasal obstruction didn’t undergone pre-operative CT. About 42% of those who had postoperative nasal deformity didn’t undergone CT while 33% of patient who had post-operative bleeding and septal perforation didn’t undergone CT.</p><p class="abstract"><strong>Conclusions:</strong> In conclusion, the study revealed that preoperative CT showed insignificant efficacy in relieving nasal obstruction or minimizing postoperative complications.</p>


2021 ◽  
pp. 014556132110002
Author(s):  
Soňa Šikolová ◽  
Dagmar Hošnová ◽  
Klára Perceová ◽  
Michal Bartoš ◽  
Vít Kruntorád ◽  
...  

Bonebridge (BB) is the first active implantation system for bone conduction that is placed fully under the skin. Experience suggests that BB is characterized by low incidence of postoperative complications. This case report presents a rare case of a 16-year-old girl with incidence of emphysema occurring over the implant 1 year after operation. We performed a computed tomography scan that showed pockets of gas above the floating mass transducer so we provided the revision surgery and sealed the artificial opening with fat from the earlobe and fibrin glue. Since that time, no air has collected in the retroauricular area and the implant has been fully functional.


Author(s):  
Halinda Fatmayanti ◽  
Kusworo Adi ◽  
Yeti Kartikasari

Background: Thorax MSCT examination is a diagnostic imaging that is capable of displaying both normal and pathological lung and respiratory organs. MSCT examination also has a better level of sensitivity and specificity compared to other modalities, but the radiation exposure given is very high, so the radiation dose given to patients is high. The reduction in radiation dose is very important because of the direct exposure to sensitive tissue. One method of reducing radiation dose is by reducing the tube voltage. However, the decrease in tube voltage causes a decrease in image quality as indicated by increased noise and decreased CNR. To maintain the quality of the image at low tube voltage setting, an IR reconstruction of SAFIRE was used. The purpose of this research is to know the impact of using SAFIRE on dose radiation and image quality of thorax MSCT.Methods: This study was an experimental study with a quasi-experimental study design. The object used was the N-1 Lungman chest phantom in which an artificial tumor was attached. Radiation dose assessment used CTDI value, while image quality assessment used noise and CNR. Data processing was conducted using linear regression test.Results: There was an effect of tube voltage setting and SAFIRE setting on radiation dose and image quality.Conclusions: Tube voltage ssetting and SAFIRE setting had an effect on radiation dose and image quality. Tube voltage setting and SAFIRE strength level setting that were able to provide optimal radiation dose and image quality were tube voltage of 80 kVp and SAFIRE strength levels 3 and 4 (S3 and S4). 


2021 ◽  
pp. 014556132110346
Author(s):  
Konstantinos Garefis ◽  
Konstantinos Tarazis ◽  
Konstantinos Gkiouzelis ◽  
Anastasia Kipriotou ◽  
Iordanis Konstantinidis ◽  
...  

A tracheal diverticulum is a type of paratracheal air cyst and is usually an incidental finding after a computed tomography scan of the neck and thorax. With an incidence between 1% and 4% in adults, tracheal diverticula are rare entities that can be symptomatic in certain cases. We present a case of a COVID-19 positive patient who presented to our hospital and was diagnosed with multiple tracheal diverticula during his hospitalization.


2021 ◽  
Vol 15 (1) ◽  
Author(s):  
Binghua Zhu ◽  
Jing Tang ◽  
Rong Fang ◽  
Xuejie Fei ◽  
Qing Wang ◽  
...  

Abstract Background We diagnosed a clinical case of pulmonary infection involving Mycobacterium tuberculosis and Tropheryma whipplei in a patient with acute respiratory distress syndrome. The diagnosis was assisted by metagenomic next-generation sequencing of bronchoalveolar lavage fluid. Case presentation A 44-year-old Han Chinese inmate was transferred to the emergency department because of dry cough, chest tightness, and shortness of breath. The patient’s body temperature rose to 39.3 °C following empirical cephalosporin treatment for 1 week. The blood CD4+/CD8+ ratio was 0.7, suggesting immunodeficiency. Routine microbiological tests were performed, and tuberculosis interferon gamma release assays were positive. Mycobacterium tuberculosis polymerase chain reaction was also positive. Chest computed tomography scan revealed miliary nodules and ground-glass opacifications, which were in accordance with tuberculosis. To fully examine the etiology, we performed routine laboratory tests and metagenomic sequencing, the results of which indicated the presence of Mycobacterium tuberculosis and Tropheryma whipplei. We administered anti-tuberculosis regimen in combination with trimethoprim/sulfamethoxazole. The patient recovered, with chest computed tomography scan showing absorption of lesions. Conclusions Compared with traditional diagnostic methods such as culture and serology, metagenomic next-generation sequencing has the advantage of detecting a wide array of microorganisms in a single test and therefore can be used for clinical diagnosis of rare pathogens and microbial coinfections. It is particularly useful for immunocompromised patients as they are more prone to infection by opportunistic microorganisms.


Author(s):  
Digamber Singh

The human respiratory tract has a complex airflow pattern. If any obstruction is present in the airways, it will change the airflow pattern and deposit particles inside the airways. This is the concern of breath quality (inspired air), and it is decreasing due to the unplanned production of material goods. This is a primary cause of respiratory illness (asthma, cancer, etc.). Therefore, it is important to identify the flow characteristics in the human airways and airways with a glomus tumour with particle deposition. A numerical diagnosis is presented with an asymmetric unsteady-state light breathing condition (10 l/min). An in vitro human respiratory tract model has been reconstructed using computed tomography scan techniques and an artificial glomus tumour developed 2 cm above a carina on the posterior wall of the trachea. The transient flow characteristics are numerically simulated with a realizable (low Reynolds number) k–ɛ turbulence model. The flow disturbance is captured around the tumour, which influenced the upstream and downstream of the flow. The flow velocity pattern, wall shear stress and probable area of inflammation (hotspot) due to suspended particle deposition are determined, which may assist doctors more effectively in aerosol therapy and prosthetics of human airways illness.


Sign in / Sign up

Export Citation Format

Share Document