scholarly journals A Stability Indicating Novel UPLC-PDA Method for the Estimation in Bulk and Capsule Dosage form of Isavuconazole Effective for Mucormycosis Caused by COVID-19 Pandemic

Author(s):  
Suman Acharyya ◽  
Si, Abhik ◽  
H. K. Sundeep Kumar

The present research provides a new proven ultra-high-performance liquid chromatographic technique for isavuconazole in both bulk and capsule dosage forms. DIKMA Waters BEH C18(50 x 2.6mm, 1.7m) column was used for chromatographic separation. With the isocratic elution mode, a mixture phosphate buffer: methanol 40:60 v/v, was used as the mobile phase, and the eluent was measured at 253 nm using a UV detector. The strategy has been maintained and validated in accordance with the International Conference on Harmonization Guidelines. Stressed deterioration has also been investigated in acidic, alkaline, peroxide, thermal, and photolytic conditions. Isavuconazole was eluted with the retention time 0.861 minute in this procedure. The calibration curve plots for isavuconazole were found to be linear within the concentration ranges of 1-25µg/mL. With a percentage recovery of 100.18 percent, the limit of detection was 0.025g/ml and the value for limit of quantification was 0.50µg/mL. In a force degradation analysis, the current approach was also determined to be stable. Based on the experiential evidence, the present method was found appropriate of isavuconazole estimation in the form of bulk and capsule.

INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


Author(s):  
Bhupender Tomar ◽  
Ankita Sharma ◽  
Inder Kumar ◽  
Sandeep Jain ◽  
Pallavi Ahirrao

A simple, precise, and accurate reverse phase high performance liquid chromatographic method (RP-HPLC) was developed and validated for the estimation of the combination of 5- Fluorouracil (5-FU) and Imiquimod in active pharmaceutical ingredients (APIs). The method was carried out on Phenomenex C18 (250 × 4.6mm I.D., 5𝜇m) using isocratic elution mode. The mobile phase was used as Acetonitrile: 10mM potassium dihydrogen orthophosphate: triethylamine (40:59.9:0.1, v/v, pH 4.5 with orthophosphoric acid) and Water: ACN (50:50 v/v) was used as a diluent. The concentration of solvents was 1-20µg/ml and the volume of injection was 20µl with the flow rate of 1.2ml/min. The retention times for 5-FU and Imiquimod were found to be 1.9±0.5 and 6.6±0.5 min respectively. The absorption maxima of 5FU and Imiquimod were found 267nm and 227nm respectively. The method was validated as per ICH guidelines. All the data were found within the specified limits. The limit of detection (LOD) and limit of quantification (LOQ) of 5- Fluorouracil were found to be 0.015μg/mL and 0.048 μg/mL, respectively, and Imiquimod was found to be 0.078μg/mL and 0.237μg/mL, respectively. The method developed in the present study was found to be sensitive, specific, and precise and can be applied for the simultaneous estimation of 5-FU and Imiquimod.


INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


Author(s):  
Sunkara Namratha ◽  
Vijayalakshmi A

Objective: Reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the assessment of lopinavir in the dosage form of tablet.Methods: Chromatogram was run through using Kromosil C18 4.5×150 mm using a mobile phase methanol: water of ratio 65:35% v/v with a rate of flow of 0.8 ml/min, measured by UV spectrometric detection at 265 nm. The method developed was validated in terms of precision, accuracy, linearity, and robustness parameters.Results: Retention time of lopinavir established at 2.482 min and percentage R.S.D of lopinavir found to be 1.0% and 0.5%, respectively. The method shows that good linearity range of 30–150 μg correlation coefficient of lopinavir was 0.997. The limit of detection was 2.97 and limit of quantification was 9.92, respectively. The percent purity of lopinavir was 99.87%.Conclusion: The suggested method (Rp-HPLC) for concurrent assay lopinavir was validated, which is appropriate method for the analysis oflopinavir quantitatively in tablet dosage forms and bulk.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (09) ◽  
pp. 68-73
Author(s):  
K Vijaya Sri ◽  
M. Shiva Kumar ◽  
M. A. Madhuri ◽  
Suresha K. ◽  

In this study, a high-performance liquid chromatographic method (HPLC) was developed, validated and applied for the determination of raltegravir in biological sample like saliva. Liquid- liquid extraction was performed for isolation of the drug and elimination of saliva interferences. Samples of saliva was extracted with 50µL of ortho phosphoric acid and 3ml of methanol was added and spiked with raltegravir. The chromatographic separation was performed on Agilent Eclipse C18 (100 mm × 4.6 mm, 3.5µm) column, by using 80:20 v/v acetonitrile: water as a mobile phase under isocratic conditions at a flow rate of 1.0 mL/min for UV detection at 240 nm. Retention time of raltegravir was found to be 1.030 min. Linearity was found to be in the range of 25-1000 ng/mL with regression equation y = 13864x + 40495 and correlation coefficient 0.999. The low % RSD value indicates the method is accurate and precise. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.76 and 2.28 ng/mL, respectively. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of raltegravir in saliva.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
S. Sowjanya ◽  
Ch. Devadasu

A reverse phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for simultaneous estimation of levamisole and albendazole in drug substance and in its combinational dosage form. The analysis was carried out usingInertsil ODSC18(4.6 x 150 mm, 5μm) column, and the separation was carried out using a mobile phase containing a buffer of pH 3.5 and acetonitrile (70:30 v/v) pumped at a flow rate of 1.0 mL/min with variable wavelength UV-detection at 224 nm. Both the drugs were well resolved in the stationary phase and the retention times were 2.350 min and 4.055 for levamisole and albendazole, respectively. The method was validated and shown to be linear in the concentration range of 15-45μg/ml and 40-120μg/ml for levamisole and albendazole, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were determined based on standard deviation of the y-intercept and the slope of the calibration curve. LOD and LOQ values were 2.08μg/ml and 6.03μg/ml for levamisole and 3.15μg/ml and 10.40μg/ml for albendazole, respectively. The accuracy of the method was assessed by adding known amount of standard solution (75 %, 100 %, and 125% of the sample concentration) to the preanalyzed sample solution of 100% concentration. All the samples were prepared and analyzed in triplicate. The percentage mean recovery by standard addition experiments of levamisole and albendazole is 99.66% and 98.73%, respectively.


2010 ◽  
Vol 7 (2) ◽  
pp. 600-604 ◽  
Author(s):  
A. Lakshmana Rao ◽  
V. Naga Jahnavi

A rapid and sensitive high performance liquid chromatographic method was developed for the estimation of levetiracetam in bulk and pharmaceutical formulations. Levetiracetam was chromatographed on a reverse phase C18column in a mobile phase consisting of 0.05 M KH2PO4buffer (pH 3.0 adjusted with orthophosphoric acid) and methanol in the ratio 70:30 v/v. The mobile phase was pumped at a flow rate of 1.2 mL/min. with detection at 210 nm. The detector response was linear in the concentration of 20-120 μg/mL. The limit of detection and limit of quantification was found to be 0.0104 and 0.0317 μg/mL, respectively. The intra and inter day variation was found to be less than 1%. The mean recovery of the drug from the solution containing 100 µg/mL was 100.038 μg/mL. The proposed method is simple, fast, accurate, precise and reproducible hence can be applied for routine quality control analysis of levetiracetam in bulk and pharmaceutical formulations.


2013 ◽  
Vol 10 (3) ◽  
pp. 1014-1022
Author(s):  
Baghdad Science Journal

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml respectively. The method was validated for its linearity, precision and accuracy .The proposed method was successfully applied for the determination of guaifenesin in syrups and industrial effluent samples.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (01) ◽  
pp. 20-25
Author(s):  
S. M Samyuktha ◽  
◽  
P. G Prasanthi ◽  
K Mahesh ◽  
B. N Nalluri ◽  
...  

A simple, selective, accurate High Performance Liquid Chromatographic (HPLC) method was developed and validated for the analysis of Fenspiride hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved isocratically using a C18 reverse phase column [Inertsil C18 column (250×4.6mm, 5μm)] utilizing a mobile phase containing 10mM Ammonium acetate: Acetonitrile (50:50 v/v) at a flow rate of 1 mL/min. The eluents were monitored at wavelength of 210 nm for a run time of 7 minutes at ambient temperature. The average retention time of the drug was found to be 4.6 minutes. The developed method was validated as per ICH guidelines to ascertain the reproducibility of the method. The method was found to be linear in the concentration range of 10-50 μg/mL with a good correlation coefficient of 0.998. The limit of detection (LOD) and limit of quantification (LOQ) were 0.007 and 0.021 μg/mL and the percentage recovery and assay were found to be 99.315 and 98.97%. Specificity with placebo by 3 D plots showed that the method was specific and free from interfering substances. Therefore, the fully validated method was good enough to carry out routine analysis of Fenspiride in bulk and tablet formulations.


Sign in / Sign up

Export Citation Format

Share Document