microfluidic analysis
Recently Published Documents


TOTAL DOCUMENTS

99
(FIVE YEARS 28)

H-INDEX

20
(FIVE YEARS 3)

2021 ◽  
Vol 53 ◽  
pp. 101712
Author(s):  
Abhishek Ratanpara ◽  
Alexander Shaw ◽  
Mallory Thomas ◽  
Rajesh N. Patel ◽  
Myeongsub Kim

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Murat Kuscu ◽  
Hamideh Ramezani ◽  
Ergin Dinc ◽  
Shahab Akhavan ◽  
Ozgur B. Akan

AbstractBio-inspired molecular communications (MC), where molecules are used to transfer information, is the most promising technique to realise the Internet of Nano Things (IoNT), thanks to its inherent biocompatibility, energy-efficiency, and reliability in physiologically-relevant environments. Despite a substantial body of theoretical work concerning MC, the lack of practical micro/nanoscale MC devices and MC testbeds has led researchers to make overly simplifying assumptions about the implications of the channel conditions and the physical architectures of the practical transceivers in developing theoretical models and devising communication methods for MC. On the other hand, MC imposes unique challenges resulting from the highly complex, nonlinear, time-varying channel properties that cannot be always tackled by conventional information and communication tools and technologies (ICT). As a result, the reliability of the existing MC methods, which are mostly adopted from electromagnetic communications and not validated with practical testbeds, is highly questionable. As the first step to remove this discrepancy, in this study, we report on the fabrication of a nanoscale MC receiver based on graphene field-effect transistor biosensors. We perform its ICT characterisation in a custom-designed microfluidic MC system with the information encoded into the concentration of single-stranded DNA molecules. This experimental platform is the first practical implementation of a micro/nanoscale MC system with nanoscale MC receivers, and can serve as a testbed for developing realistic MC methods and IoNT applications.


2021 ◽  
pp. 131530
Author(s):  
Kuan-Hong Chen ◽  
Chan-Chiung Liu ◽  
Song-Yu Lu ◽  
Szu-Jui Chen ◽  
Fuu Sheu ◽  
...  

2021 ◽  
Author(s):  
Yuanchen Yu ◽  
Felix Dempwolff ◽  
Reid T. Oshiro ◽  
Frederico J. Gueiros-Filho ◽  
Stephen C. Jacobson ◽  
...  

During growth, bacteria increase in size and divide. Division is initiated by the formation of the Z-ring, a ring-like cytoskeletal structure formed by treadmilling protofilaments of the tubulin homolog FtsZ. FtsZ localization is thought to be controlled by the Min and Noc systems, and here, we explore why cell division fails at high temperature when the Min and Noc systems are simultaneously mutated. Microfluidic analysis of a minD noc double mutant indicated that FtsZ formed proto-Z-rings at periodic inter-chromosome locations but that the rings failed to mature and become functional. Extragenic suppressor analysis indicated that a variety of mutations restored high temperature growth to the minD noc double mutant, and while many were likely pleiotropic, others implicated the proteolysis of the transcription factor Spx. Further analysis indicated that a Spx-dependent pathway activated the expression of ZapA, a protein that primarily compensates for the absence of Noc. Additionally, an Spx-independent pathway increased the activity of the divisome to reduce the length of the cytokinetic period. Finally, we provide evidence of an as-yet-unidentified protein that is activated by Spx and governs the frequency of polar division and minicell formation. IMPORTANCE Bacteria must properly position the location of the cell division machinery in order to grow, divide, and ensure each daughter cell receives one copy of the chromosome. In B. subtilis , cell division site selection depends on the Min and Noc systems, and while neither is individually essential, cells fail to grow at high temperature when both are mutated. Here, we show that cell division fails in the absence of Min and Noc, not due to a defect in FtsZ localization, but rather a failure in the maturation of the cell division machinery. Suppressor mutations that restored growth were selected and while some activated the expression of ZapA via the Spx stress response pathway, others appeared to directly enhance divisome activity.


Micromachines ◽  
2021 ◽  
Vol 12 (7) ◽  
pp. 744
Author(s):  
Liuyong Shi ◽  
Hanghang Ding ◽  
Xiangtao Zhong ◽  
Binfeng Yin ◽  
Zhenyu Liu ◽  
...  

In this paper, we present a novel microfluidic mixer with staggered virtual electrode based on light-actuated AC electroosmosis (LACE). We solve the coupled system of the flow field described by Navier–Stokes equations, the described electric field by a Laplace equation, and the concentration field described by a convection–diffusion equation via a finite-element method (FEM). Moreover, we study the distribution of the flow, electric, and concentration fields in the microchannel, and reveal the generating mechanism of the rotating vortex on the cross-section of the microchannel and the mixing mechanism of the fluid sample. We also explore the influence of several key geometric parameters such as the length, width, and spacing of the virtual electrode, and the height of the microchannel on mixing performance; the relatively optimal mixer structure is thus obtained. The current micromixer provides a favorable fluid-mixing method based on an optical virtual electrode, and could promote the comprehensive integration of functions in modern microfluidic-analysis systems.


2021 ◽  
Vol 13 (13) ◽  
pp. 7061
Author(s):  
Athanasia K. Tolkou ◽  
Natalia Manousi ◽  
George A. Zachariadis ◽  
Ioannis A. Katsoyiannis ◽  
Eleni A. Deliyanni

In recent years, there has been an increase in public perception of the detrimental side-effects of fluoride to human health due to its effects on teeth and bones. Today, there is a plethora of techniques available for the removal of fluoride from drinking water. Among them, adsorption is a very prospective method because of its handy operation, cost efficiency, and high selectivity. Along with efforts to assist fluoride removal from drinking waters, extensive attention has been also paid to the accurate measurement of fluoride in water. Currently, the analytical methods that are used for fluoride determination can be classified into chromatographic methods (e.g., ionic chromatography), electrochemical methods (e.g., voltammetry, potentiometry, and polarography), spectroscopic methods (e.g., molecular absorption spectrometry), microfluidic analysis (e.g., flow injection analysis and sequential injection analysis), titration, and sensors. In this review article, we discuss the available techniques and the ongoing effort for achieving enhanced fluoride removal by applying novel adsorbents such as carbon-based materials (i.e., activated carbon, graphene oxide, and carbon nanotubes) and nanostructured materials, combining metals and their oxides or hydroxides as well as natural materials. Emphasis has been given to the use of lanthanum (La) in the modification of materials, both activated carbon and hybrid materials (i.e., La/Mg/Si-AC, La/MA, LaFeO3 NPs), and in the use of MgO nanostructures, which are found to exhibit an adsorption capacity of up to 29,131 mg g−1. The existing analytical methodologies and the current trends in analytical chemistry for fluoride determination in drinking water are also discussed.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 558
Author(s):  
Hwee-Yeong Ng ◽  
Wen-Chin Lee ◽  
Chia-Te Kung ◽  
Lung-Chih Li ◽  
Chien-Te Lee ◽  
...  

Milk is a necessity for human life. However, it is susceptible to contamination and adulteration. Microfluidic analysis devices have attracted significant attention for the high-throughput quality inspection and contaminant analysis of milk samples in recent years. This review describes the major proposals presented in the literature for the pretreatment, contaminant detection, and quality inspection of milk samples using microfluidic lab-on-a-chip and lab-on-paper platforms in the past five years. The review focuses on the sample separation, sample extraction, and sample preconcentration/amplification steps of the pretreatment process and the determination of aflatoxins, antibiotics, drugs, melamine, and foodborne pathogens in the detection process. Recent proposals for the general quality inspection of milk samples, including the viscosity and presence of adulteration, are also discussed. The review concludes with a brief perspective on the challenges facing the future development of microfluidic devices for the analysis of milk samples in the coming years.


Sign in / Sign up

Export Citation Format

Share Document