electrophoresis separation
Recently Published Documents


TOTAL DOCUMENTS

200
(FIVE YEARS 12)

H-INDEX

33
(FIVE YEARS 3)

Micromachines ◽  
2021 ◽  
Vol 12 (11) ◽  
pp. 1433
Author(s):  
Muhammad Noman Hasan ◽  
Ran An ◽  
Asya Akkus ◽  
Derya Akkaynak ◽  
Adrienne R. Minerick ◽  
...  

Paper-based microchip electrophoresis has the potential to bring laboratory electrophoresis tests to the point of need. However, high electric potential and current values induce pH and temperature shifts, which may affect biomolecule electrophoretic mobility thus decrease test reproducibility and accuracy of paper-based microfluidic electrophoresis. We have previously developed a microchip electrophoresis system, HemeChip, which has the capability of providing low-cost, rapid, reproducible, and accurate point-of-care (POC) electrophoresis tests for hemoglobin analysis. Here, we report the methodologies we implemented for characterizing HemeChip system pH and temperature during the development process, including utilizing commercially available universal pH indicator and digital camera pH shift characterization, and infrared camera characterizing temperature shift characterization. The characterization results demonstrated that pH shifts up to 1.1 units, a pH gradient up to 0.11 units/mm, temperature shifts up to 40 °C, and a temperature gradient up to 0.5 °C/mm existed in the system. Finally, we report an acid pre-treatment of the separation media, a cellulose acetate paper, mitigated both pH and temperature shifts and provided a stable environment for reproducible HemeChip hemoglobin electrophoresis separation.


Author(s):  
Fabio Galeotti ◽  
Federica Capitani ◽  
Francesca Maccari ◽  
Veronica Mantovani ◽  
Nicola Volpi

Abstract Propolis is important in complementary and alternative medicine having well-known therapeutic applications. Artepillin C, a main component of Brazilian (green) propolis, has attracted great attention for its anticancer action. Consequently, the synthesis of artepillin C has been reported but, due to the limited yield and elevated costs, this biomolecule is largely produced from Brazilian propolis. We report the capillary electrophoresis (CE) separation of artepillin C in Brazilian propolis also comparing the results with those of HPLC-UV-MS. Optimal separation was obtained with a simple buffer constituted of sodium tetraborate 30 mM pH 9.2 and detection at 210 nm. Artepillin C and the polyphenols of propolis were fully separated with a voltage gradient of 30 to 8 kV and a current of 300 μA for a total run of 50 min. The sensitivity of CE-UV was 22 times greater than HPLC-UV and 100 times more than HPLC-MS with also a stronger reduction in the run time and a greater robustness and reproducibility. The development of CE as an effective and reliable method for the analysis of artepillin C is desired as the standardized quality controls are essential before propolis or its biomolecules can be adopted routinely in nutraceuticals, food ingredients and therapeutic applications.


The Analyst ◽  
2020 ◽  
Vol 145 (5) ◽  
pp. 1768-1776 ◽  
Author(s):  
Shamal M. Gunawardhana ◽  
Galina A. Bulgakova ◽  
Anton M. Barybin ◽  
Sara R. Thomas ◽  
Susan M. Lunte

Development of an easily fabricated MD–ME–EC set up for continuous on-line in vivo monitoring of neuroactive compounds in rat brain including dopamine.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Alina A. Kokorina ◽  
Artem A. Bakal ◽  
Daria V. Shpuntova ◽  
Alexandr Yu. Kostritskiy ◽  
Natalia V. Beloglazova ◽  
...  

Abstract We investigated light emission of hydrothermally treated citric acid and ethylenediamine (EDA) with various precursor ratios using gel-electrophoresis. We show that this relatively simple approach can deliver significant insights into the origins of photoluminescence. We found that products of the synthesis consist of both positively and negatively charged species and exhibit large dispersion in electrophoretic mobility (i.e. charge-to-size ratio). We observed that despite the large dispersion of the reaction products the blue light emission is confined to discrete bands clearly identifiable in the gel. We demonstrate clear evidence that this emission originates from the negatively charged light molecular fraction with the highest mobility which shows no excitation-dependent light emission. This molecular fluorophore exhibits spectral characteristics similar to previously reported 1,2,3,5-tetrahydro-5-oxo-imidazo[1,2-a]pyridine-7-carboxylic acid (IPCA). Secondary gel electrophoresis run performed on the bands extracted from the first run indicates that no further separation takes place. On the basis of our experimental results, we conclude that relatively stable binding exists between IPCA and EDA-derived product. Thus, the products of the reaction contain IPCA both in molecular form and in complexes with EDA-derived products. We conclude that excitation-dependent emission is related to the fluorophore binding to the positively charged EDA-derived products with a positive charge.


Micromachines ◽  
2019 ◽  
Vol 10 (9) ◽  
pp. 605 ◽  
Author(s):  
Bonabi ◽  
Tähkä ◽  
Ollikainen ◽  
Jokinen ◽  
Sikanen

Organically modified ceramic polymers (ORMOCERs) have attracted substantial interest in biomicrofluidic applications owing to their inherent biocompatibility and high optical transparency even in the near-ultraviolet (UV) range. However, the processes for metallization of ORMOCERs as well as for sealing of metallized surfaces have not been fully developed. In this study, we developed metallization processes for a commercial ORMOCER formulation, Ormocomp, covering several commonly used metals, including aluminum, silver, gold, and platinum. The obtained metallizations were systematically characterized with respect to adhesion (with and without adhesion layers), resistivity, and stability during use (in electrochemical assays). In addition to metal adhesion, the possibility for Ormocomp bonding over each metal as well as sufficient step coverage to guarantee conductivity over topographical features (e.g., over microchannel edges) was addressed with a view to the implementation of not only planar, but also three-dimensional on-chip sensing elements. The feasibility of the developed metallization for implementation of microfluidic electrochemical assays was demonstrated by fabricating an electrophoresis separation chip, compatible with a commercial bipotentiostat, and incorporating integrated working, reference, and auxiliary electrodes for amperometric detection of an electrochemically active pharmaceutical, acetaminophen.


Sign in / Sign up

Export Citation Format

Share Document