frequency transducer
Recently Published Documents


TOTAL DOCUMENTS

123
(FIVE YEARS 21)

H-INDEX

12
(FIVE YEARS 1)

Author(s):  
Yong-jian Zhao ◽  
Xiao-long Zhu ◽  
Pei-yu Luo ◽  
Ang Li ◽  
Wei Xiao ◽  
...  

Abstract Objective This paper proposes a new photoacoustic computed tomography (PACT) imaging system employing dual ultrasonic transducers with different frequencies. When imaging complex biological tissues, photoacoustic (PA) signals with multiple frequencies are produced simultaneously; however, due to the limited bandwidth of a single-frequency transducer, the received PA signals with specific frequencies may be missing, leading to a low imaging quality. Methods In contrast to our previous work, the proposed system has a compact volume as well as specific selection of the detection center frequency of the transducer, which can provide a comprehensive range for the detection of PA signals. In this study, a series of numerical simulation and phantom experiments were performed to validate the efficacy of the developed PACT system. Results The images generated by our system combined the advantages of both high resolution and ideal brightness/contrast. Conclusion The interchangeability of transducers with different frequencies provides potential for clinical deployment under the circumstance where a single frequency transducer cannot perform well.


2021 ◽  
Author(s):  
Zhiqiang Li ◽  
Dongze Li ◽  
Suoyuan Li ◽  
Weiwei Shao ◽  
Peiyang Li ◽  
...  

Abstract Background: Ultrasound has been proved to be a promising alternative spine navigation method. High frequency ultrasound transducer has the advantage of high resolution on surface structure, but imaging at close range is difficult, especially in narrow space of the pilot-hole in pedicle.Methods: Twenty cortical bone chips were made and different size of hole with diameter of 1mm, 2mm, 3mm or 5mm was randomly carved in each bone chip. A tailored 30MHz high frequency transducer scanned bone samples at the distance of 4mm, 3mm, 2mm and 1mm. Successive transmission ringingeffect elimination, Hilbert transform and Gray-scale mapping method were utilized to process and optimize attained original images.Results: At the distance of 4mm, 3mm, 2mm and 1mm, the holes with diameter of 5mm, 3mm and 2mm could be discerned. At the distance of 1mm, only the holes with 5mm and 3mm could be clearly distinguished and the 2mm hole appeared obscure. The holes with diameter of 1mm could not be detected at any distance. The holes with diameter of 2mm were able to be detected at the distance of 1mm.Conclusions: This study indicated that the high frequency transducer had limited imaging capability at close range on the bony surface. These results lay a foundation for further developing a novel ultrasound-based spinal pedicle interior imaging and navigation system.


Author(s):  
Jing Yang ◽  
Emmanuel Cherin ◽  
Jianhua Yin ◽  
Isabel G. Newsome ◽  
Thomas M. Kierski ◽  
...  

2021 ◽  
Vol 41 ◽  
Author(s):  
Igor C.K. da Cruz ◽  
Maria L.A. Mestieri ◽  
João P.E. Pascon ◽  
Mauren P. Emanuelli ◽  
Maria E. Trost ◽  
...  

ABSTRACT: The aim of this study was to verify the applicability and accuracy of B-mode ultrasonography in detecting malignancy in dog cutaneous neoplasms. Forty-two neoplasms (12 benign and 30 malignant) of mesenchymal, round cells, epithelial and melanocytic origins from 24 dogs of different breeds and ages were included. The ultrasound evaluation was performed with a linear multi-frequency transducer (7.0 to 12MHz), with frequency dependent on the mass dimension. Ultrasonographic characteristics of echogenicity (hypo/hyperechogenic), echotexture (homogeneous/heterogeneous), regularity, invasiveness in adjacent tissues were classified. Dimensions were also measured to calculate the depth/width ratio. Neoplasms were classified as malignant or benign after cytological and/or histopathological analysis and the results were associated with ultrasound characteristics. There was a significant association (P<0.05) between malignancy and echogenicity, echotexture and invasiveness in adjacent tissues, so that 84.6% of hypoechogenic neoplasms, 76.9% of heterogeneous masses and 88.2% of invasive neoplasms were classified as malignant. However, for all these associations, moderate predictive values were obtained, which may be due to the small experimental number included in this study. Therefore, although it has been observed that hypoechogenic, heterogeneous and invasive neoplasms were more prone to malignancy, these findings should be used with caution until new studies are developed with a greater number and variety of cutaneous neoplasms in dogs.


2020 ◽  
Author(s):  
Gebhard Mathis ◽  
Rudolf Horn ◽  
Susanne Morf ◽  
Helmut Prosch ◽  
Serena Rovida ◽  
...  

The analysis of vertical reverberation artefacts is an essential component of the differential diagnosis in pulmonary ultra-sound. Traditionally, they are often, but not exclusively, called B-line artefacts (BLA) and/or comet tail artefacts (CTA), but this view is misleading. In this position paper we clarify the terminology and relation of the two lung reverberation artefacts BLA and CTA to spe-cific clinical scenarios. BLA are defined by a normal pleura line and are a typical hallmark of cardiogenic pulmonary edema after exclusion of certain pathologies including pneumonia or lung contusion, whereas CTAs show an irregular pleura line representing a variety of parenchymal lung diseases. The dual approach using low frequency transducers to determine BLA and high frequency transducer to determine the pleural surface is recommended.


2020 ◽  
Vol 10 (23) ◽  
pp. 8388
Author(s):  
Ngoc Thang Bui ◽  
Thi My Tien Nguyen ◽  
Tran Thanh Nam Dinh ◽  
Quoc Cuong Bui ◽  
Tan Hung Vo ◽  
...  

Scanning acoustic microcopy (SAM) is widely used in biomedical and industrial applications in dermatology, ophthalmology, intravascular imaging, and small animal images, owing to SAM’s ability to photograph small structures with a good spatial resolution. One of the most important devices of this system is the pulser/receiver (P/R) (PRN-300, Ohlabs Corporation, Nam-gu Busan, Republic of Korea), which generates pulses to trigger a high-frequency transducer. This article presents the design of a pulse generator to excite high-frequency transducers with four channels. The characteristics of the pulses, such as time and frequency, can be reconfigured by using a high-speed field programmable gate array (FPGA). The configuration software was developed for communicating with the P/R device via a USB connector for easy, feasible pulse selection and real-time pulse management. Besides that, during the design and implementation of the hardware, we optimized the damping resistor value to reduce the overshoot and undershoot part of the signal, ensuring the best effect on the transducer signal. The test results show that unipolar pulses worked with transducers with frequencies over 100 MHz. The SAM systems can work simultaneously with multiple transducers, and the resulting images have different resolutions of regions.


2020 ◽  
Vol 31 (12) ◽  
pp. 125011
Author(s):  
Zhangjian Li ◽  
Zhile Han ◽  
Xiaohua Jian ◽  
Weiwei Shao ◽  
Yang Jiao ◽  
...  

2020 ◽  
Vol 24 (3) ◽  
pp. 36-42
Author(s):  
Jae-Yeop Choi ◽  
Nguyen Thanh Phong Truong ◽  
Van Hiep Pham ◽  
Minh Tri Boc ◽  
Byung-Gak Kim ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document