effective slip length
Recently Published Documents


TOTAL DOCUMENTS

35
(FIVE YEARS 11)

H-INDEX

11
(FIVE YEARS 1)

Author(s):  
А.С. Лобасов ◽  
А.В. Минаков

The results of numerical investigation of the hydrodynamic drag of a slit microchannel with a textured wall surface, as well as the pressure drop in such a channel and the effective slip length on the wall for various Reynolds numbers, are presented. The channel height was 10 µm, and the length varied from 25 to 500 µm. It was found that the pressure drop in the textured microchannel was less than in a conventional channel for any of its lengths. The dependences of the relative pressure drop, the friction factor, and the effective slip length on the Reynolds number were obtained for various channel lengths. A correlation that describes the dependence of the relative pressure drop on the Reynolds number for small channel lengths was proposed. The friction factor is described by a correlation of form 20 / Re.


2021 ◽  
Vol 2119 (1) ◽  
pp. 012050
Author(s):  
A S Lobasov ◽  
A V Minakov

Abstract The numerical investigation of the fluid flow in a slit microchannel with a textured wall was carried out. The effect of the channel height on the hydrodynamic drag coefficient, as well as on the pressure drop in such channel and the effective slip length on the wall for various Reynolds numbers, are presented in the paper. The channel length was 100 µm, and its height was varied from 25 µm to 500 µm. The Reynolds number was varied from 0.1 to 100. The main studied characteristics were compared to the similar ones obtained for a channel with normal walls (no-slip conditions). It was found that the pressure drop in such textured microchannel was lower as compared to a conventional channel for any of its heights and for any Reynolds numbers. The dependences of the relative pressure drop, effective slip length, and drag coefficient on the Reynolds number were obtained for different channel heights. The drag coefficient was described as 20/Re for the average values of the channel height. A correlation that describes the dependence of the friction factor on the Reynolds number for small and large heights of the channel was proposed. The accuracy of the proposed correlation was about 90%.


2021 ◽  
Vol 12 ◽  
pp. 1237-1251
Author(s):  
Ruifei Wang ◽  
Jin Chai ◽  
Bobo Luo ◽  
Xiong Liu ◽  
Jianting Zhang ◽  
...  

The slip boundary condition for nanoflows is a key component of nanohydrodynamics theory, and can play a significant role in the design and fabrication of nanofluidic devices. In this review, focused on the slip boundary conditions for nanoconfined liquid flows, we firstly summarize some basic concepts about slip length including its definition and categories. Then, the effects of different interfacial properties on slip length are analyzed. On strong hydrophilic surfaces, a negative slip length exists and varies with the external driving force. In addition, depending on whether there is a true slip length, the amplitude of surface roughness has different influences on the effective slip length. The composition of surface textures, including isotropic and anisotropic textures, can also affect the effective slip length. Finally, potential applications of nanofluidics with a tunable slip length are discussed and future directions related to slip boundary conditions for nanoscale flow systems are addressed.


2021 ◽  
Author(s):  
◽  
Nathaniel Joseph Lund

<p>In this thesis, homogenization and perturbation methods are used to derive analytic expressions for effective slip lengths for Stokes flow over rough, mixed-slip surfaces, where the roughness is periodic, and the variation in slip length has the same period. If the classical no-slip boundary condition of fluid mechanics is relaxed, the slip velocity of the fluid at the surface is non-zero. For simple shear flow, the slip velocity is proportional to the shear rate. The constant of proportionality has dimensions of length and is known as the slip length. Any variation in the slip length over the surface will cause a perturbation to the flow adjacent to the surface. Due to the diffusion of momentum, at sufficient height above the surface, the flow perturbations have diminished, and flow is smooth and uniform. The velocity and shear rate at this height imply an effective slip length of the surface. The purpose of this thesis is to predict that effective slip length.  Homogenization is a technique for finding approximate solutions to partial differential equations. The essence of homogenization is to construct a mathematical model of a physical problem featuring some periodic heterogeneity, then generate a sequence of models such that the period in question reduces with each increment in the sequence. If the sequence is appropriately defined, it has a limit model in the limit of vanishing period, for which a solution can be found. The solution to the limit system is an approximation to the solutions of systems with a finite period.  We use homogenization to find the effective slip length of a system of Stokes flow over a periodically rough surface, described by periodic function h(x; y), with a local slip length b(x; y) varying with the same period. For systems where the period L is smaller than both the domain height P and typical slip lengths, the effective slip length bₑff is well-approximated by the harmonic mean of local slip lengths, weighted by area of contact between liquid and surface: [See 'Thesis' document below for equation.]  We further use a perturbation technique to verify the above expression in the special case of a flat surface, and to derive another effective slip length expression: For a flat surface with local slip lengths much smaller than the period and domain height, the effective slip length bₑff is well-approximated by the area-weighted average of local slip lengths: [See 'Thesis' document below for equation.]</p>


2021 ◽  
Author(s):  
◽  
Nathaniel Joseph Lund

<p>In this thesis, homogenization and perturbation methods are used to derive analytic expressions for effective slip lengths for Stokes flow over rough, mixed-slip surfaces, where the roughness is periodic, and the variation in slip length has the same period. If the classical no-slip boundary condition of fluid mechanics is relaxed, the slip velocity of the fluid at the surface is non-zero. For simple shear flow, the slip velocity is proportional to the shear rate. The constant of proportionality has dimensions of length and is known as the slip length. Any variation in the slip length over the surface will cause a perturbation to the flow adjacent to the surface. Due to the diffusion of momentum, at sufficient height above the surface, the flow perturbations have diminished, and flow is smooth and uniform. The velocity and shear rate at this height imply an effective slip length of the surface. The purpose of this thesis is to predict that effective slip length.  Homogenization is a technique for finding approximate solutions to partial differential equations. The essence of homogenization is to construct a mathematical model of a physical problem featuring some periodic heterogeneity, then generate a sequence of models such that the period in question reduces with each increment in the sequence. If the sequence is appropriately defined, it has a limit model in the limit of vanishing period, for which a solution can be found. The solution to the limit system is an approximation to the solutions of systems with a finite period.  We use homogenization to find the effective slip length of a system of Stokes flow over a periodically rough surface, described by periodic function h(x; y), with a local slip length b(x; y) varying with the same period. For systems where the period L is smaller than both the domain height P and typical slip lengths, the effective slip length bₑff is well-approximated by the harmonic mean of local slip lengths, weighted by area of contact between liquid and surface: [See 'Thesis' document below for equation.]  We further use a perturbation technique to verify the above expression in the special case of a flat surface, and to derive another effective slip length expression: For a flat surface with local slip lengths much smaller than the period and domain height, the effective slip length bₑff is well-approximated by the area-weighted average of local slip lengths: [See 'Thesis' document below for equation.]</p>


2021 ◽  
Vol 54 (1) ◽  
Author(s):  
Steffen Hardt ◽  
Glen McHale

Liquid-infused surfaces (LISs) are composite solid–liquid surfaces with remarkable features such as liquid repellency, self-healing, and the suppression of fouling. This review focuses on the fluid mechanics on LISs, that is, the interaction of surfaces with a flow field and the behavior of drops on such surfaces. LISs can be characterized by an effective slip length that is closely related to their drag reduction property, which makes them suitable for several applications, especially for turbulent flows. Drag reduction, however, is compromised by failure mechanisms such as the drainage of lubricant from surface textures. The flow field can also sculpt the lubricant layer in a coupled self-organization process. For drops, the lubricant reduces drop pinning and increases drop mobility, but also results in a wetting ridge and the associated concept of an apparent contact angle. Design of LIS wettability and topography can induce low-friction drop motion, and drops can dynamically shape the lubricant ridges and film thickness. Expected final online publication date for the Annual Review of Fluid Mechanics, Volume 54 is January 2022. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.


Micromachines ◽  
2021 ◽  
Vol 12 (7) ◽  
pp. 752
Author(s):  
Porui Tian ◽  
Yifan Li

In the development of micro/nano fluid control systems, fluid resistance has always been one of the key factors restricting its development. According to previous studies, it is found that the boundary slip effect of the solid-liquid interface can effectively reduce the resistance of the microfluid and improve the transport efficiency of the microfluid. The boundary slip length is mainly affected by surface wettability, roughness, and surface charge density. Among them, the influence mechanism of surface charge density on the boundary slip is the most complicated, and there is a lack of relevant research, and further investigation is needed. In this paper, we present research on quantification of effective slip length and surface charge density, where the roughness effect is considered. The electrostatic and hydrodynamic force data obtained from atomic force microscopy (AFM) measurements were fitted and processed for comparative analysis. We obtained the variation of surface charge density and effective slip length when different oleophobic surface samples were immersed in ethylene glycol with different pH values. The effect of pH on the surface charge density and effective slip length was investigated by their variations. The mechanism of the effect of pH on the surface charge density was discussed. The experimental results show that in the ethylene glycol solution, no matter whether the pH value of the solution increases or decreases, the charge density of the surface with the same properties decreases, and the effective boundary slip length also shows a downward trend. In deionized water, the surface charge density and effective boundary slip length decreases with the decrease of PH value.


Author(s):  
Fanhui Zeng ◽  
Qiang Zhang ◽  
Jianchun Guo ◽  
Yu Zhang ◽  
Wenxi Ren ◽  
...  

Abstract The capillary spontaneous imbibition length of slick water in confined rectangular cross-sectional nanofractures is investigated in this paper. In the established model, the effective slip length, effective viscosity, wettability and nanofracture size are incorporated into the modified Hagen–Poiseuille equation. The calculated spontaneous imbibition length as a function of time, viscosity, wettability and pore size is qualitatively validated by experimental and previous theoretical Hagen–Poiseuille flow results. Our model calculation results agree well with the published experimental data. The ratio of the effective and bulk water viscosities is higher than one, and increases with an increase in the ratio of the nanofracture width to height and decreasing contact angle. The spontaneous imbibition capacity of confined water is enhanced ∼0.67–1.28 times, as determined by the Hagen–Poiseuille equation without the slip effect for various contact angles and nanofracture dimensions.


Sign in / Sign up

Export Citation Format

Share Document