dental resin composites
Recently Published Documents


TOTAL DOCUMENTS

207
(FIVE YEARS 47)

H-INDEX

39
(FIVE YEARS 4)

ACS Omega ◽  
2021 ◽  
Author(s):  
Qiting Huang ◽  
Zelin Liang ◽  
Junda Li ◽  
Ying Bai ◽  
Jingwei He ◽  
...  

Author(s):  
Kiho Cho ◽  
Ginu Rajan ◽  
Paul Farrar ◽  
Leon Prentice ◽  
B. Gangadhara Prusty

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Matej Par ◽  
Katica Prskalo ◽  
Tobias T. Tauböck ◽  
Hrvoje Skenderovic ◽  
Thomas Attin ◽  
...  

AbstractThis study aimed to investigate polymerization kinetics and curing light transmittance of two series of experimental dental resin composites filled with 0–40 wt% of either 45S5 bioactive glass (BG) or a customized low-Na F-containing BG. Polymerization kinetics in 0.1-mm and 2-mm thick layers were investigated through real-time degree of conversion measurements using a Fourier transform infrared (FTIR) spectrometer. FTIR spectra were continuously collected at a rate of 2 s−1 during light-curing (1340 mW/cm2). Light transmittance through 2-mm thick composite specimens was measured using a UV–Vis spectrometer at a rate of 20 s−1. Unlike BG 45S5, which led to a dose-dependent reduction in the rate and extent of polymerization, the customized low-Na F-containing BG showed a negligible influence on polymerization. The reduction in light transmittance of experimental composites due to the addition of the low-Na F-containing BG did not translate into impaired polymerization kinetics. Additionally, the comparison of polymerization kinetics between 0.1-mm and 2-mm thick layers revealed that polymerization inhibition identified for BG 45S5 was not mediated by an impaired light transmittance, indicating a direct effect of BG 45S5 on polymerization reaction. A customized low-Na F-containing BG showed favourable behaviour for being used as a functional filler in light-curing dental resin composites.


Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5612
Author(s):  
Jiani Liu ◽  
Hao Zhang ◽  
Huijun Sun ◽  
Yanru Liu ◽  
Wenlin Liu ◽  
...  

Dental resin composites (DRCs) with diverse fillers added are widely-used restorative materials to repair tooth defects. The addition of fillers brings an improvement in the mechanical properties of DRCs. In the past decade, diverse fillers have emerged. However, the change of emerging fillers mainly focuses on the chemical composition, while the morphologic characteristics changes are often ignored. The fillers with new morphologies not only have the advantages of traditional fillers (particles, fibrous filler, etc.), but also endow some additional functional characteristics (stronger bonding ability to resin matrix, polymerization resistance, and wear resistance, drug release control ability, etc.). Moreover, some new morphologies are closely related to the improvement of traditional fillers, porous filler vs. glass particles, core-sheath fibrous vs. fibrous, etc. Some other new morphology fillers are combinations of traditional fillers, UHA vs. HA particles and fibrous, tetrapod-like whisker vs. whisker and fibrous filler, mesoporous silica vs. porous and silica particles. In this review, we give an overall description and a preliminary summary of the fillers, as well as our perspectives on the future direction of the development of novel fillers for next-generation DRCs.


Polymers ◽  
2021 ◽  
Vol 13 (16) ◽  
pp. 2814
Author(s):  
Niklas Burgard ◽  
Melanie Kienitz ◽  
Claudia Jourdan ◽  
Stefan Rüttermann

The purpose of the study was to investigate the bacterial viability of the initial biofilm on the surface of experimental modified dental resin composites. Twenty-five healthy individuals with good oral hygiene were included in this study. In a split-mouth design, they received acrylic splints with five experimental composite resin specimens. Four of them were modified with either a novel polymeric hollow-bead delivery system or methacrylated polymerizable Irgasan (Antibacterial B), while one specimen served as an unmodified control (ST). A delivery system based on Poly-Pore® was loaded with one of the active agents: Tego® Protect 5000 (Antiadhesive A), Dimethicone (Antiadhesive B), or Irgasan (Antibacterial A). All study subjects refrained from toothbrushing during the study period. Specimens were detached from the splints after 8 h and given a live/dead staining before fluorescence microscopy. A Friedman test and a post hoc Nemenyi test were applied with a significance level at p < 0.05. In summary, all materials but Antibacterial B showed a significant antibacterial effect compared to ST. The results suggested the role of the materials’ chemistry in the dominance of cell adhesion. In conclusion, dental resin composites with Poly-Pore-loaded active agents showed antibacterial effectiveness in situ.


Author(s):  
Niklas Burgard ◽  
Melanie Kienitz ◽  
Claudia Jourdan ◽  
Stefan Rüttermann

The purpose of the study was to investigate the bacterial viability of the initial biofilm on the surface of experimental modified dental resin composites. Twenty-five healthy individuals with good oral hygiene were included in this study. In a split-mouth design, they received acrylic splints with five experimental composite resin specimens. Four of them were modified with either a novel polymeric hollow beads delivery system or methacrylated polymerizable Irgasan (Antibacterial B), while one specimen served as unmodified control (ST). The delivery system based on Poly-Pore&reg; was loaded with one of the active agents Tego&reg; Protect 5000 (Antiadhesive A), Dimethicone (Antiadhesive B) or Irgasan (Antibacterial A). All study subjects refrained from toothbrushing during the study period. Specimens were detached from the splints after 8h and given a live/dead staining before fluorescence microscopy. Friedman test and post-hoc Nemenyi test were applied with significance level at p &amp;lt; 0.05. In summary all materials but Antibacterial B showed a significant antibacterial effect compared to ST. In conclusion dental resin composites with Poly-Pore loaded active agents show antibacterial effectiveness in situ.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2769
Author(s):  
Jonne Oja ◽  
Lippo Lassila ◽  
Pekka K. Vallittu ◽  
Sufyan Garoushi

The aim of current in vitro research was to determine the effect of hydrothermal accelerated aging on the mechanical properties and wear of different commercial dental resin composites (RCs). In addition, the effect of expiration date of the composite prior its use was also evaluated. Five commercially available RCs were studied: Conventional RCs (Filtek Supreme XTE, G-aenial Posterior, Denfil, and >3y expired Supreme XTE), bulk-fill RC (Filtek Bulk Fill), and short fiber-reinforced RC (everX Posterior). Three-point flexural test was used for determination of ultimate flexural strength (n = 8). A vickers indenter was used for testing surface microhardness. A wear test was conducted with 15,000 chewing cycles using a dual-axis chewing simulator. Wear pattern was analyzed by a three-dimensional (3D) noncontact optical profilometer. Degree of C=C bond conversion of monomers was determined by FTIR-spectrometry. The specimens were either dry stored for 48 h (37 °C) or boiled (100 °C) for 16 h before testing. Scanning electron microscopy (SEM) was used to evaluate the microstructure of each material. Data were analyzed using ANOVA (p = 0.05). Hydrothermal aging had no significant effects on the surface wear and microhardness of tested RCs (p > 0.05). While flexural strength significantly decreased after aging (p < 0.05), except for G-aenial Posterior, which showed no differences. The lowest average wear depth was found for Filtek Bulk Fill (29 µm) (p < 0.05), while everX Posterior and Denfil showed the highest wear depth values (40, 39 µm) in both conditions. Passing the expiration date for 40 months did not affect the flexural strength and wear of tested RC. SEM demonstrated a significant number of small pits on Denfil’s surface after aging. It was concluded that the effect of accelerated aging may have caused certain weakening of the RC of some brands, whereas no effect was found with one brand of RC. Thus, the accelerated aging appeared to be more dependent on material and tested material property.


Sign in / Sign up

Export Citation Format

Share Document