cyclic siloxanes
Recently Published Documents


TOTAL DOCUMENTS

93
(FIVE YEARS 8)

H-INDEX

18
(FIVE YEARS 2)

2020 ◽  
Vol 21 (17) ◽  
pp. 6375
Author(s):  
Krystyna Mojsiewicz-Pieńkowska ◽  
Ewa Stachowska ◽  
Dominika Krenczkowska ◽  
Dagmara Bazar ◽  
Frans Meijer

Cyclic siloxanes (D4, D5, D6) are widely used in skin products. They improve skin sensory properties and alleviate dry skin, but there is still one report (published 2019), which regards their effects on the destruction of the skin barrier, by using fluorescence microscopy and attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR). A new skin-imaging technique, digital holographic microscopy (DHM), was used for the first time to investigate the impact of D4, D5, and D6 on the skin barrier. We observed irreversible damage of the stratum corneum due to the interaction with cyclic siloxanes. These substances changed: (a) the first level of the skin barrier through destabilization of the intercellular lipid lamellae and destruction of the corneocyte structure (measured with axial nanometer resolution), (b) the second level by collapse of not only corneocytes but also of a significant part of the clusters, leading to the loss of the stratum corneum integrity and formation of the lacunae, (c) the third level as an effect of the change in the surface geometrical topography of the stratum corneum and disruption of the integrity of this skin layer, measured with lateral micrometer resolution. DHM allowed also to identify an important pathway for substances to penetrate into the skin through canyons surrounding the clusters. Our investigations provide advanced information for understanding the mechanisms by which various substances pass the skin barrier, including uncontrolled diffusion into the skin.


Pharmaceutics ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 586 ◽  
Author(s):  
Dominika Krenczkowska ◽  
Krystyna Mojsiewicz-Pieńkowska ◽  
Bartosz Wielgomas ◽  
Dagmara Bazar ◽  
Zbigniew Jankowski

Cyclic methylsiloxanes D4, D5, D6 (also called cyclic silicones) are widely used in various dermatological products and cosmetics, both for children and adults. As a result of their unique physicochemical properties, the production of cyclic methylsiloxanes has greatly increased over the last few years, which has resulted in increased exposure to mankind. The validated quantitative for gas chromatography-flame ionization detector (GC-FID) analysis with using the transdermal diffusion system with vertical Franz cells demonstrated that ex vivo human skin is not a barrier to cyclic siloxanes. D4, D5, and D6 have a specific affinity to stratum corneum (SC) (especially D6), and can even diffuse into the deeper layers of the skin (epidermis (E) and dermis (D)), or into the receptor fluid as well. An important achievement of this work was the observation of the characteristic ratio partitioning D4, D5, and D6 in skin layers and receptor fluid (RF). The studies have shown that, in order to thoroughly understand the mechanism, it is important to determine not only the differences in the amounts of cumulated doses in total in all skin layers and receptor fluid, but also the mutual ratios of analyte concentrations existing between matrices. For example, in the case of the stratum corneum, the cumulative doses of D4, D5, and D6 were 27.5, 63.9, and 67.2 µg/cm2/24 h, respectively, and in the epidermis, they were 6.9, 29.9, and 10.7 µg/cm2/24 h, respectively, which confirmed the highest affinity of D6 to stratum corneum as the amount diffused into the epidermis was 2.8 times smaller compared to D5. The calculated epidermis-to-stratum corneum ratios of analyte concentrations also confirm this. The largest ratio was identified for D5 (E/SC = 47), followed by D4 (E/SC = 25), and finally by D6 (E/SC = 16). The analysis of the next stage of diffusion from epidermis to dermis revealed that in dermis the highest cumulative dose was observed for D5 (13.9 µg/cm2/24 h), while the doses of D4 and D6 were similar (5.1 and 5.3 µg/cm2/24 h). Considering the concentration gradient, it can be concluded that the diffusion of D5 and D6 occurs at a similar level, while D4 diffuses at a much higher level. These observations were also confirmed by the dermis-to-epidermis concentration ratios. The final stage of diffusion from dermis to the receptor fluid indicated that D4 was able to permeate easily, while D5 exhibited a difficult diffusion and the diffusion of D6 was limited. The receptor fluid-to-dermis concentration ratios (RF/D) were calculated for D4, D5, and D6: 80, 53, and 17, respectively. Our results also revealed the increased risk of D4 and D5 absorption into the blood and lymphatic systems, whereas D6 demonstrated the lowest risk. Therefore, we can argue that, among the three tested compounds, D6 is the safest one that can be used in dermatological, cosmetic, and personal care products. This study demonstrates that the stratum corneum, epidermis, and dermis can be also considered reservoirs of cyclic methylsiloxanes. Therefore, these compounds can demonstrate potential long-term bioaccumulation, and can be absorbed to the bloodstream in a long-term and uncontrolled process.


Chemosphere ◽  
2020 ◽  
Vol 241 ◽  
pp. 125126
Author(s):  
Benjamin M. King ◽  
Nathan J. Janechek ◽  
Nathan Bryngelson ◽  
Andrea Adamcakova-Dodd ◽  
Traci Lersch ◽  
...  
Keyword(s):  

2020 ◽  
Vol 1 (9) ◽  
pp. 3358-3368
Author(s):  
Nicha Prigyai ◽  
Supphachok Chanmungkalakul ◽  
Sutthiroj Thanyalax ◽  
Mongkol Sukwattanasinitt ◽  
Vuthichai Ervithayasuporn

When cyclic siloxanes were exposed to fluoride ions, a blue-shift and enhanced fluorescence emissions appeared in most organic solvents.


2019 ◽  
Vol 378 ◽  
pp. 122152 ◽  
Author(s):  
Vu Tung Lam Tran ◽  
Patrick Gélin ◽  
Corinne Ferronato ◽  
Jean–Marc Chovelon ◽  
Ludovic Fine ◽  
...  

2019 ◽  
Vol 282 ◽  
pp. 187-196 ◽  
Author(s):  
Georgiana-Oana Turcan-Trofin ◽  
Mihai Asandulesa ◽  
Mihaela Balan-Porcarasu ◽  
Cristian-Dragos Varganici ◽  
Vasile Tiron ◽  
...  

Author(s):  
Tri Tran

Cyclic siloxanes are widely used in beauty products as softener and polisher. Howeve, very few studies have reported the occurrence and amount of cyclic siloxanes in personal care products (PCPs). In this research, the analysis method of cyclic siloxanes including octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), and dodecamethylcyclohexasiloxane (D6) in PCPs was developed by using a gas chromatography-mass spectrometry (GC/MS) system. The method detection limits and the method quantification limits of individual cyclic siloxanes were 0.7 ng/g and 2.0 ng/g, respectively. Mean recoveries of surrogate compound (M4Q) and target compounds for the procedural blanks ranged from 88.5 to 94.9%. The recoveries of M4Q for real samples ranged from 75.5 to 120% (RSD: 6.8%). The optimal procedure was applied to measure the amount of D4, D5, and D6 in several samples of PCPs including shampoos, hair gels, and shower gels collected from retail stores in Hanoi, Vietnam. Mean concentrations of D4, D5 and D6 in PCPs ranged of 0.313 – 5.61 µg/g, 0.683 – 11.7 µg/g, and 0.294 – 3.38 µg/g, respectively.


Sign in / Sign up

Export Citation Format

Share Document