clinical alarms
Recently Published Documents


TOTAL DOCUMENTS

55
(FIVE YEARS 14)

H-INDEX

12
(FIVE YEARS 1)

Author(s):  
Verónica Martínez-Borba ◽  
Carlos Suso-Ribera ◽  
Amanda Díaz-García ◽  
Judith Salat-Batlle ◽  
Diana Castilla ◽  
...  

Attempts to optimize monitoring of brace adherence prescribed to adolescents with idiopathic scoliosis (IS) have generally relied on sensors. Sensors, however, are intrusive and do not allow the assessment of psychological and physical consequences of brace use that might underlie poor adherence. Mobile applications have emerged as alternatives to monitor brace compliance. However, the feasibility and utility of these app-based systems to assess key psychological and physical domains associated with non-adherence remain unexplored. This feasibility study aims to test the usability, acceptability, and clinical utility of an app-based system that monitors brace use and related psychological and physical factors. Forty adolescents with IS daily respond to the app for 90 days. The patient responses may generate clinical alarms (e.g., brace non-adherence, discomfort, or distress) that will be sent daily to the medical team. Primary outcomes will be app usability, acceptability, and response rates. Secondary outcomes will include brace adherence, the number of side effects reported, number and type of clinical alarms, stress, quality of life, perceived health status, and mood. If accepted by patients and clinicians, apps may allow rapid detection and response to undesired events in adolescents undergoing brace treatment.


Author(s):  
Francisco Villegas ◽  
Verónica Martínez-Borba ◽  
Carlos Suso-Ribera ◽  
Diana Castilla ◽  
Irene Zaragoza ◽  
...  

Background: mobile applications (apps) facilitate cancer pain ecological momentary assessment (EMA) and provide more reliable data than retrospective monitoring. The aims of this study are (a) to describe the status of persons with cancer pain when assessed ecologically, (b) to analyze the utility of clinical alarms integrated into the app, and (c) to test the feasibility of implementing an app for daily oncological pain monitoring. Methods: in this feasibility study, 21 patients (mean age = 56.95 years, SD = 10.53, 81.0% men) responded to an app-based evaluation of physical status (baseline and breakthrough cancer pain (BTcP)) and mental health variables (fatigue, mood, and coping) daily during 30 days. Results: cancer pain characterization with the app was similar to data from the literature using retrospective assessments in terms of BTcP duration and perceived medication effectiveness. However, BTcP was less frequent when evaluated ecologically. Pain, fatigue, and mood were comparable in the morning and evening. Passive coping strategies were the most employed daily. Clinical alarms appear to be useful to detect and address adverse events. App implementation was feasible and acceptable. Conclusion: apps reduce recall bias and facilitate a rapid response to adverse events in oncological care. Future efforts should be addressed to integrate EMA and ecological momentary interventions to facilitate pain self-management via apps.


2021 ◽  
Vol 30 (3) ◽  
pp. 186-192
Author(s):  
Burcu Ceylan ◽  
Leyla Baran ◽  
Ülkü Yapucu Güneş

Background All clinical alarms require nurses to respond even if an intervention is not needed. Nurses are expected to respond appropriately to each alarm and establish priorities among their care practices accordingly. This study was conducted to examine the number and types of clinical device alarms used in intensive care units, the duration of their activation, and nurses’ degree of sensitivity to them. Methods This observational study was conducted in 4 intensive care units in a university hospital in Turkey. A total of 20 nurses (5 from each unit) were observed for a total of 80 hours. The alarms were categorized as valid, false, or technical. Results During the study observation period, the mean number of alarms sounding per hour per bed was 1.8. A total of 144 alarms were recorded, of which 70.8% were valid, 15.3% were false, and 13.9% were technical. The mean duration of alarm activation was 8 minutes for valid alarms, 14 minutes for false alarms, and 53 minutes for technical alarms. Conclusions Nurses’ responses to alarms differ depending on alarm type; for alarms that do not require an emergency intervention, nurses tend to respond late or not at all.


Author(s):  
Soo-Joung Lee ◽  
Yun-Mi Lee ◽  
Eun Ji Seo ◽  
Youn-Jung Son

This study aimed to identify the impact of nurses’ perception of clinical alarms and patient safety culture on alarm management. Additionally, we aimed to describe the importance of clinical alarm issues. The data were collected from 21 August to 10 September 2020. The study participants were 116 nurses working in a tertiary acute care hospital in Korea. The self-report questionnaire included general characteristics, clinical alarm issues, nurses’ alarm perception, patient safety culture, and alarm management practice. The mean age of nurses was 28.04 ± 4.06 years, with 5.71 ± 4.35 years of total clinical experience. For the importance of alarm issues, frequent false alarms leading to reduced attention or response was the most important issue. Hierarchical linear regression analysis revealed that a higher level of nurses’ perceived patient safety culture was the strongest predictor of better alarm management practice (p < 0.001), followed by their perception of clinical alarms (p = 0.034). In addition, female nurses (p = 0.004), charge nurses (p = 0.013), and nurses who work less than 40 h per week (p = 0.008) were more likely to work better in alarm management practice. Future studies are needed to develop standardized alarm management guidelines by improving nurses’ positive perceptions of clinical alarms and patient safety culture.


Author(s):  
Thangavelu S. D. ◽  
Supriyanto E. ◽  
Yunus J.

Almost all medical devices in ICU/CCU have a built-in clinical alarm system to alert when there are changes in a patient’s condition. The objective of this study is to investigate the effectiveness of the existing alarm system in ICU/CCU. Two summative usability tests were conducted to test the effectiveness of existing and new alarm signals based on IEC 60601-1-8:2006 standard. Further formative test is conducted to study the perception of urgency associated with a number of tones in the alarm signals. The findings indicate that the existing auditory alarm signal in ICU/CCU does not indicate the urgency of the alarm conditions. The simulation test indicates that the respondents preferred 282Hz, 500Hz and 800Hz for low, medium and high-risk alarm respectively. The one-sample proportion z test on urgency mapping indicates that the proportion of responses for the highest risk is more than 50% for a single tone test signal. These results show that a single tone test signal being perceived as the highest risk is regardless of frequency. It can be concluded the auditory alarm designed based on this IEC 60608-1-8:2006 standard is not effective. As such it is proposed that the incorporation of the new alarm frequencies and tones will improve the effectiveness of the alarm signal


2020 ◽  
Vol 29 (5) ◽  
pp. 390-395
Author(s):  
Debbie Leigher ◽  
Paula Kemppainen ◽  
David M. Neyens

Background Nurses in intensive care units are exposed to hundreds of alarms during a shift, and research shows that most alarms are not clinically relevant. Alarm fatigue can occur when a nurse becomes desensitized to alarms. Alarm fatigue can jeopardize patient safety, and adverse alarm events can lead to patients dying. Objective To evaluate how a process intervention affects the number of alarms during an 8-hour shift in an intensive care unit. Methods A total of 62 patients from an intensive care unit were included in the study; 32 of these patients received the intervention, which included washing the patient’s chest with soap and water and applying new electrocardiography electrodes at the start of a shift. The number of alarms, clinical diagnoses, and demographic variables were collected for each patient. A Poisson regression model was used to evaluate the impact of the intervention on the overall number of clinical alarms during the shift, with no adjustments to the alarm settings or other interventions. Results After relevant covariates are controlled for, the results suggest that patients in the intervention group presented significantly fewer alarms than did patients in the control group. Conclusions Managing clinical alarms is a main issue in terms of both patient safety and staff workload management. The results of this study demonstrate that a relatively simple process-oriented strategy can decrease the number of alarms.


Sign in / Sign up