drift capacity
Recently Published Documents


TOTAL DOCUMENTS

54
(FIVE YEARS 22)

H-INDEX

8
(FIVE YEARS 3)

Author(s):  
Jitendra Bhatta ◽  
Joshua Mulligan ◽  
Rajesh P. Dhakal ◽  
Timothy J. Sullivan ◽  
Hans Gerlich ◽  
...  

This paper identifies the inherent strengths/weaknesses of rigid timber-framed partitions and quantifies the onset drifts for different damage thresholds under bi-directional seismic actions. It reports construction and quasi-static lateral cyclic testing of a multi-winged timber-framed partition wall specimen with details typical of New Zealand construction practice. Furthermore, the cyclic performance of the tested rigid timber-framed partition wall is also compared with that of similar partition walls incorporating ‘partly-sliding’ connectiondetails, and ‘seismic gaps’, previously tested under the same test setup. Based on the experimentally recorded cyclic performance measures, theoretical equations proposed/derived in the literature to predict the ultimate strength, initial stiffness, and drift capacity of different damage states are scrutinized, and some equations are updated in order to alleviate identified possible shortcomings. These theoretical estimates are then validated with the experimental results. It is found that the equations can reasonably predict the initial stiffness and ultimate shear strength of the partitions, as well as the onset-driftscorresponding to the screw damage and diagonal buckling failure mode of the plasterboard. The predicted bi-linear curve is also found to approximate the backbone curve of the tested partition wall sensibly.


Buildings ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 597
Author(s):  
Ali M. Memari ◽  
Nicholas Simmons ◽  
Ryan L. Solnosky

In the cyclic racking evaluation of curtain wall systems, physical testing with instrumentation is the standard method for collecting performance data by most design professionals. The resulting testing of full-scale mockups can provide many types of data, including load and displacement values at different stages of loading through failure. While this type of data is valuable for product/system development/fabrication and design, such data can also provide a means for simulation validation of the curtain wall cyclic performance under simulated earthquake loading. Once the simulation study is validated using the test results, then parametric studies by designers can be conducted with greater ease, ideally with commercial software packages, without the need for testing. For the results of this research study, a practical industry formulated finite element modeling (FEM) approach was used to predict the performance of the curtain wall mockups. Here, unitized four-sided structural sealant glazing (4SSG) curtain wall system mockups that incorporate a re-entrant corner were subjected to cyclic racking displacements per the American Architectural Manufacturers Association (AAMA) 501.6 Structural Sealant protocol. System performances, including displacements, were obtained from the FEM study and used to calculate the effective shear strain of the structural silicone and the drift capacity of the system. This paper describes the details of the techniques developed for FEM, the analysis results, and shows an example application of the numerical modeling approach for mockups with racking test results available. The goal of this modeling approach was to create and test methods that practicing consulting engineers can quickly conduct in their offices on common commercially available software often available to them.


Buildings ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 593
Author(s):  
Ali M. Memari ◽  
Nicholas Simmons ◽  
Ryan L. Solnosky

Curtain wall glazing systems are a major part of a building due to the multiple roles they have, including occupant protection against environmental effects and the transfer of loads to the structural system. From a structural perspective, limited analytical guidelines and methods exist to aid designers in their determination of the curtain wall performance without extensive simulation or laboratory testing. This study takes experimental data from full-scale, “unitized”, four-sided structural sealant glazing (4SSG) curtain wall system mockups featuring a re-entrant corner subjected to cyclic racking displacements in accordance with the American Architectural Manufacturers Association AAMA 501.6 protocol to derive and establish equations that predict the relative displacements of the glass relative to the glazing frame, based on the amount of inter-story drift. Through derivation and testing, sealant cohesive failure and glass cracking were identified as limit states and corresponding drift levels were determined to control many of the equations. Displacements from the newly derived equations were correlated to the effective shear strain value experienced by the structural silicone in the mockup concurrently with the curtain wall’s drift capacity. This paper provides detailed derivation of the kinematic equations for possible use by glazing design professionals. Such equations can help designers to more easily predict the drifts that cause damage to such systems by manual calculations without the need for expensive mockup testing or time-intensive computer models.


Author(s):  
Nima Aghniaey ◽  
Murat Saatcioglu ◽  
Hassan Aoude

Research on seismic behaviour of shear walls with high-strength steel is limited. A combined experimental and analytical investigation was conducted to assess seismic behaviour of flexure-dominant shear walls. A large-scale concrete shear wall with Grade 690 MPa (ASTM A1035) reinforcement and 84 MPa concrete was tested under simulated seismic loading. The wall was a ¼ -scale of a 6-storey shear wall, with 4.53 m height and 1.45 m length. It sustained a lateral drift of 1.8% prior to developing failure due to the rupturing of longitudinal reinforcement. This is 35% less than the drift capacity of a companion wall reinforced with 400 MPa reinforcement tested earlier. VecTor2 software was used to conduct an analytical parametric study to expand the experimental findings. The results indicate that the reinforcement grade has a significant impact on strength, ductility and hysteretic behaviour of shear walls.


Author(s):  
Amr Elsayed Mohammed Abdallah ◽  
Ehab Fathy El-Salakawy

The mechanical and physical properties of glass fiber-reinforced polymer (GFRP) reinforcement are different from steel, which requires independent code provisions for GFRP-reinforced concrete (RC) members. The currently available code provisions for GFRP-RC members still need more research evidence to be inclusive. For example, the available provisions for confinement reinforcement of FRP-RC columns do not consider the effects of column aspect ratio, which is not yet supported by any available research data. In this study, two full-scale spirally reinforced GFRP-RC circular columns were constructed and tested under concurrent seismic and axial loads. Both specimens had an aspect ratio (shear span-to-diameter ratio) of 7.0, while other two specimens with an aspect ratio of 5.0, from a previous stage of this study, were included for comparison purposes. For each aspect ratio, each specimen was loaded under one of two levels of axial load; 20 or 30% of the axial load capacity of the column section. All test specimens had a 35 MPa concrete compressive strength, 350-mm diameter, 85-mm spiral pitch and 1.2% longitudinal reinforcement ratio. The experimental results were analyzed in terms of hysteretic response, drift capacity and inelastic deformability hinge length. Based on the experimental results, it can be concluded that the aspect ratio affects the magnitude of secondary moments and inelastic deformability hinge length. In addition, the aspect ratio may affect drift capacity of GFRP-RC columns, depending on axial load level.


2021 ◽  
Vol 11 (3) ◽  
pp. 207-222
Author(s):  
Ganchai Tanapornraweekit ◽  
Rajendra Prasad Bohara ◽  
Somnuk Tangtermsirikul

A large number of low to moderate earthquake incidents have been witnessed in the northern and western parts of Thailand. These incidents usually lead to various damage levels in various structures. Therefore, a sufficient lateral force resisting structures should be designed for the construction in such earthquake-prone areas. This paper presents the relevance of using a typical composite wide U beam-column system for mitigation of structural failure and collapse from the seismic hazard in Thailand. The investigated composite structural system consists of precast U beams, precast columns, and cast-in-situ concrete over the precast U beams and in the joint regions. The system also includes post-tensioning in the cast-in-situ area of the composite beams. The system has widely been used in low- to mid-rise commercial building in Thailand. In order to scrutinize the seismic performance of the system, a half-scale specimen of the post-tensioned precast U beam-column joint was tested under an incremental displacement-controlled lateral cyclic load. The laboratory test revealed the drift capacity, damage pattern, strain development in the rebars etc. of the precast wide U beam-column interior joint. Based on the obtained drift capacity, displacement-based assessment of the system was carried out. In addition, the observed damages on the tested structure were evaluated using damage grading criteria for building subjected to earthquake. The assessment showed a high potential of the post-tensioned precast wide U beam-column system to mitigate the structural failure and collapse from the earthquake hazard. However, some improvements in the current seismic performance of the system are required to employ the system in high seismic zones.