double pulse
Recently Published Documents


TOTAL DOCUMENTS

1064
(FIVE YEARS 181)

H-INDEX

58
(FIVE YEARS 5)

Author(s):  
Yibin Liu ◽  
Chunyang Wang ◽  
Jian Gong ◽  
Ming Tan

Abstract By combining multiple input multiple output (MIMO) technology and multiple matched filters with frequency diverse array (FDA), FDA-MIMO radar can be used to achieve two-dimensional target localization with range and angle. In this paper, we propose two FDA-MIMO multi-pulse target localization methods based on tensor decomposition. Based on the canonical polyadic decomposition theory, the signal models of CPD-DP-FDA with double-pulse and CPD-SP-FDA with stepped frequency pulses are established. By analyzing the signal processing procedures of the two schemes, the indicator beampattern used for target localization is obtained. The parameter estimation accuracy of the proposed method is investigated in single target and multiple targets scenarios, and the proposed method is compared with the traditional double-pulse method. The results show that the target localization method based on tensor decomposition can effectively solve the problem of multi-target indication ambiguity. The target positioning effect can be further improved by combining stepped frequency pulses. The derivation of Cramer–Rao Lower Bound (CRLB) demonstrates the superiority of the method.


Author(s):  
Boudewijn van den Berg ◽  
Hemme J. Hijma ◽  
Ingrid Koopmans ◽  
Robert J. Doll ◽  
Rob G. J. A. Zuiker ◽  
...  

AbstractSleep deprivation has been shown to increase pain intensity and decrease pain thresholds in healthy subjects. In chronic pain patients, sleep impairment often worsens the perceived pain intensity. This increased pain perception is the result of altered nociceptive processing. We recently developed a method to quantify and monitor altered nociceptive processing by simultaneous tracking of psychophysical detection thresholds and recording of evoked cortical potentials during intra-epidermal electric stimulation. In this study, we assessed the sensitivity of nociceptive detection thresholds and evoked potentials to altered nociceptive processing after sleep deprivation in an exploratory study with 24 healthy male and 24 healthy female subjects. In each subject, we tracked nociceptive detection thresholds and recorded central evoked potentials in response to 180 single- and 180 double-pulse intra-epidermal electric stimuli. Results showed that the detection thresholds for single- and double-pulse stimuli and the average central evoked potential for single-pulse stimuli were significantly decreased after sleep deprivation. When analyzed separated by sex, these effects were only significant in the male population. Multivariate analysis showed that the decrease of central evoked potential was associated with a decrease of task-related evoked activity. Measurement repetition led to a decrease of the detection threshold to double-pulse stimuli in the mixed and the female population, but did not significantly affect any other outcome measures. These results suggest that simultaneous tracking of psychophysical detection thresholds and evoked potentials is a useful method to observe altered nociceptive processing after sleep deprivation, but is also sensitive to sex differences and measurement repetition.


Author(s):  
Jozef Kozarik ◽  
Juraj Marek ◽  
Ales Chvala ◽  
Michal Minarik ◽  
Krisztian Gasparek ◽  
...  

2021 ◽  
Vol 12 (4) ◽  
pp. 323-331
Author(s):  
A. V. Isaev ◽  
U. V. Suchodolov ◽  
A. S. Sushko ◽  
A. A. Sheinikau

In modern diagnostics, much attention is paid to measuring of time parameters, as well as their change over time. The purpose of this work is to develop a method for measuring of time intervals which made it possible to increase the measurement accuracy by reducing errors associated with the instability of main parameters of the pulse signal.In the most of approaches used, the error associated with the instability of main parameters of signals under study is not enough taken into account. As an alternative, a spectral method is proposed in which the measurement of time intervals, as well as their changes, is performed based on the analysis of pulse sequences formed on the basis of characteristic points of the measured signal. For this a double pulse sequence was considered, an equation for the amplitudes of its spectral components was obtained, and in accordance with this it was determined that the delay time between double pulses is the most informative parameter.Using the Mathcad software, an analysis of the sensitivity regions was carried out for the change in the main parameters of the pulse sequence, namely the repetition rate, as the main destabilizing factor.As a result of the implementation of the developed technique, a structural diagram of the measuring system is proposed and an analysis of the measurement error associated with the instability of the main parameters of the pulse sequence is carried out. This error is estimated to be less than 0.01 %.The considered method makes it possible to increase the accuracy of measuring time intervals due to the almost complete elimination of the influence of the instability of the reference frequency and the amplitude of the generated pulses which is unattainable with modern hardware, including digital signal processing. 


2021 ◽  
Vol 128 (1) ◽  
Author(s):  
S. Hartwell ◽  
A. Azima ◽  
C. Haunhorst ◽  
M. Kazemi ◽  
M. Namboodiri ◽  
...  

AbstractControlling the temporal and spectral properties of ultrashort laser pulses in the visible and near-infrared spectral range by means of a femtosecond pulse-shaping device is a powerful tool with many applications in ultrafast spectroscopy. A major and successful concept is known as the 4f design, which has a symmetric zero-dispersion-compressor geometry. Most 4f pulse shapers rely on using transmissive optics in their beam path limiting the operational wavelength ranges. In the present contribution, we use an all-reflective shaping setup to generate a phase-locked 266 nm double pulse to benchmark its performance in the limit of short wavelengths. The setup comprises the complete spectral amplitude and phase diagnostics for quantitative analysis of the pulse properties before and after the shaper using the technique of frequency-resolved optical gating. The measured time–frequency spectra are in good agreement with optical simulations. The geometry and hardware of the device including the optical components are designed, such that all harmonics of the deep UV pulses travel the same path, giving the instrument the ability to work with soft X-ray pulses, under vacuum conditions, down to the few-nanometer wavelength scale.


2021 ◽  
Vol 119 (23) ◽  
pp. 231603
Author(s):  
Keisuke Takenaka ◽  
Naoki Shinohara ◽  
Masaki Hashida ◽  
Mitsuhiro Kusaba ◽  
Hitoshi Sakagami ◽  
...  

2021 ◽  
Author(s):  
Dongkai Chu ◽  
Weizhen Li ◽  
Shuoshuo Qu ◽  
xianran dong ◽  
Peng Yao

Sign in / Sign up

Export Citation Format

Share Document