optimization and performance
Recently Published Documents


TOTAL DOCUMENTS

404
(FIVE YEARS 119)

H-INDEX

31
(FIVE YEARS 5)

2021 ◽  
Vol 7 (12) ◽  
pp. 120075-120088
Author(s):  
Fabio Barros De Sousa ◽  
Simone Cristina da Costa Tavares ◽  
Jorge Everaldo De Oliveira ◽  
Jackson Moreira De Oliveira ◽  
Elizabeth Rego Sabino ◽  
...  

Neste trabalho, investigamos um método de compensação de dispersão para as taxas de transmissão de 10 Gbps e 40 Gbps com formatos de modulação retorno ao zero (return to zero - RZ) e não retorno ao zero (non-return to zero - NRZ) usando fibra monomodo (single mode-fiber - SMF) e fibra compensadora de dispersão (dispersion compensating fiber - DCF). A influência da dispersão do compensador DCF com o aumento da potência do laser CW foi estudada, afim de se avaliar o desempenho dos sistemas de comunicação por fibra óptica aqui propostos. Os resultados da simulação foram validados através do formato do pulso, do espectro óptico e do diagrama de olho para a análise do fator Q e da taxa de erro de bit (bit error rate – BER).


Energies ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 7359
Author(s):  
Annalisa Liccardo ◽  
Francesco Bonavolontà ◽  
Ignazio Romano ◽  
Rosario Schiano Lo Moriello

Ensuring service continuity has become a fundamental issue for companies involved in electricity distribution; in particular, isolating the smallest possible portion of the network as a result of faults has long been a primary objective. To this aim, solutions based on logic selectivity have been defined and implemented for an efficient search for the network branch affected by the fault and its subsequent isolation. The authors have recently presented a proposal for the implementation of logic selectivity that exploits the LoRa transmission protocol, an ideal solution in the case of areas not reachable by the currently exploited communication technologies. The present paper, instead, deals with the optimization of some LoRa parameters, which made it possible to exploit network configurations in terms of coverage range, sensitivity and signal-to-noise ratio. The performance of the new configuration has been assessed through a number of tests conducted in the laboratory and on-field, highlighting promising results in terms of both intervention times and reliability. In particular, tests conducted in both rural and urban areas have assured fault isolation times as low as 33 ms (fully compliant with the current regulations) in the presence of the most challenging fault condition.


Sign in / Sign up

Export Citation Format

Share Document