black globe temperature
Recently Published Documents


TOTAL DOCUMENTS

26
(FIVE YEARS 12)

H-INDEX

5
(FIVE YEARS 1)

2021 ◽  
pp. 1-20
Author(s):  
Juan A. Acero ◽  
Angela Dissegna ◽  
Yon Sun Tan ◽  
Adrian Tan ◽  
Leslie K. Norford ◽  
...  

2021 ◽  
Vol XXXVII (1) ◽  
pp. 5-15
Author(s):  
Magdalena Młynarczyk ◽  
Maria kONARSKA

The assessment of maximum allowable heat load of a body in a hot environment is determined using the WBGT index. The name of the WBGT index is derived from the measurement of two parameters: natural wet-bulb temperature and black globe temperature. WBGT as an indicator used to assess the heat load (until 2017) was related to the metabolic heat production and placed in the form of tables in the Polish edition of Standard No.PN-EN 27243:2005 (and PN-EN 27243:2005P). In 2017, this standard was replaced by Standard No. EN ISO 7243:2017, and in January 2018, the Polish translation of Standard No. PN-EN ISO 7243:2018-01 was approved. This article describes the methodology of conducting WBGT research according to Standard No. PN-EN ISO 7243:2018-01. This article discusses the problems of occupational safety and health, which are covered by health sciences and environmental engineering.


2021 ◽  
Vol 14 (3) ◽  
pp. 5-13
Author(s):  
M. V. S. Chaves ◽  
W. G. Vale ◽  
M. M. Cunha ◽  
P. A. C. B. Vale ◽  
A. M. Enes ◽  
...  

Technologically advanced animal production requires more controlled environments, aiming to maximize animal performance and, consequently, the profitability of the activity. To do that, it is necessary to instrument, evaluate and diagnose the various rearing environments. Hence, Precision Animal Production is inserted in this context and aims to effectively meet the general needs of the animal, so that it reach its full productive potential, correcting the divergences between the environment and its well-being to guarantee its comfort. Since Brazil is a country with tropical climate, which is a major obstacle, the proposal of this project is to develop a prototype for embedded system of thermal comfort analysis at low cost. Using sensors and the microcontroller Arduino to manage data, this work fulfilled its objective, with a prototype device (WGV-1c) capable of measuring dry bulb temperature, wet bulb temperature, black globe temperature, relative humidity, BGHI and THI with production cost below that proposed by the market.


2020 ◽  
Vol 35 (3) ◽  
pp. 388-394
Author(s):  
Fabiana Terezinha Leal de Morais ◽  
José Pinheiro Lopes Neto ◽  
Adriana Maria dos Santos ◽  
Patrício Gomes Leite ◽  
Raissa Gonçalves Cavalcanti

CONFORTO TÉRMICO E DESEMPENHO DE POEDEIRAS NA FASE INICIAL   FABIANA TEREZINHA LEAL DE MORAIS1, JOSÉ PINHEIRO LOPES NETO2, ADRIANA MARIA DOS SANTOS3, PATRÍCIO GOMES LEITE4, RAISSA GONÇALVES CAVALCANTI5   1Doutoranda em Engenharia Agrícola: Lacra, UFCG, Avenida Assis Chateaubriand, 101, Liberdade,58414-060, Campina Grande, Paraíba, Brasil. [email protected]. 2 Doutor em Engenharia Agrícola: Lacra, UFCG, R. Aprígio Veloso, 882 - Universitário, 58428-830, Campina Grande, Paraíba, [email protected]. 3 Mestra em Engenharia Agrícola: Lacra, UFCG, R. Alencar Pires de almeida, 07 – Centro, 58748-000, Água Branca, Paraíba, [email protected]. 4 Doutor em Engenharia Agrícola: Lacra, UFCG, R. Aprígio Veloso, 882 - Universitário, 58428-830, Campina Grande, Paraíba, [email protected] 5 Mestra em Engenharia Agrícola: Lacra, UFCG, R. Aprígio Veloso, 882 - Universitário, 58428-830, Campina Grande, Paraíba, [email protected].   RESUMO: Tendo em vista a importância do conforto térmico na avicultura de postura no Brasil, o objetivo geral destapesquisa foi avaliar o conforto térmico no galpão (pinteiro), localizado em uma granja comercial no município de Cuité (PB). A avaliação foi realizada com base nos dados de Índice da Temperatura do Globo Negro e Umidade (ITGU), avaliando o desempenho das pintainhas relacionado ao ganho de peso e as coletas de dados foram realizadas diariamente.Foi utilizado um galpão destinado para a fase de cria para aves da linhagem Lohmann LSL no período da terceira semana para desenvolvimento das aves, avaliando os valores de ITGU e comparando àqueles indicados pela literatura. Como resultados, observamos que foi possível manter as faixas de conforto térmicas bem próximas ao recomendado, e o ganho de peso mantiveram-se abaixo do indicado pelo manual da linhagem, os animais submetidos a condições térmicas adversas apresentaram menor ganho de peso.   Palavras-chave: ambiência, conforto térmico, ganho de peso.   THERMAL COMFORT AND POISER PERFORMANCE IN THE INITIAL PHASE (CRIA)   ABSTRACT: Considering the importance of thermal comfort in poultry farming in Brazil. The aim of this research was to evaluate the thermal comfort in the shed (pestle), located in a commercial farm in the municipality of Cuité - PB. The evaluation was performed based on the data of air temperature (ºC), relative humidity of the air (%), the black globe temperature for determination of the Black Globe Temperature and Humidity Index (ITGU). Weight gain on chicks and data collection were performed daily. The shed for the breeding phase of the Lohmann LSL line was used in the third week for bird development, evaluating the ITGU values and comparing to those indicated in the literature, we observed that it was possible to keep the thermal comfort bands very close to the recommended one, and the weight gain remained distant to that indicated by the lineage manual, the animals submitted to adverse thermal conditions showed less weight gain.   Keywords: ambience, thermal comfort, weight gain.


2020 ◽  
pp. bjsports-2020-103048
Author(s):  
Sebastien Racinais ◽  
Marine Alhammoud ◽  
Nada Nasir ◽  
Roald Bahr

ObjectivesTo analyse 11 years of FIVB heat stress-monitoring data to determine the relative influence of the different environmental parameters in increasing the likelihood of a heat-related medical time-out (MTOheat).MethodsA total of 8530 matches were recorded. The referee measured air temperature, black globe temperature, relative humidity and wet-bulb globe temperature (WBGT) before the matches, and registered the MTOheat. The absolute humidity was computed at posteriori.ResultsThere were 20 MTOheat cases, but only 3 resulted in forfeiting the match. MTOheat incidence was not statistically impacted by sex (p=0.59). MTOheat cases were more prevalent during the games played in Asia during the 4th quarter of the year (p<0.001). Two cases of MTOheat experienced diarrhoea or gastroenteritis during the 5 preceding days; both of them forfeited the match. A principal component analysis showed a specific environmental profile for the matches with MTOheat. They occurred at higher WBGT, temperatures and absolute humidity (p<0.001), but with a lower relative humidity (p=0.027).ConclusionsThe current data showed that an increase in ambient or black globe temperature, but not relative humidity, increased the risk of a MTOheat; but that the absolute risk remained low in elite beach volleyball players. However, suffering or recovering from a recent illness may represent a risk factor for a MTOheat to lead to player forfeit.


2020 ◽  
pp. 1420326X2091436
Author(s):  
Xiaojing Meng ◽  
Yihang Lv ◽  
Honggang Yang ◽  
Yi Wang

The aim of this study is to evaluate the cooling effect of a spray fan in an indoor hot environment. An experimental workplace with a thermal environment of high temperature and radiation intensity was set up. The hot environment of the experimental workplace could not meet occupational health requirements when the heat source temperature exceeded 150°C. The effects of air velocity and relative humidity on the natural wet bulb temperature, black globe temperature and wet bulb globe temperature (WBGT) were investigated. The maximum reduction of the WBGT was about 1.7°C, with an air velocity increase by 1 m/s. There was a notable cooling effect on the hot environment for low air velocities (e.g. 0–2 m/s), while the cooling effect only increased slightly for high air velocity (e.g. 2–5 m/s). We also found that the indoor WBGT declined by 0.2–0.8°C when the relative humidity was increased by about 10%. These results may provide guidance for reducing heat stress in industrial hot environment.


Author(s):  
Carlos Vargas-Salgado ◽  
Cristian Chiñas-Palacios ◽  
Jesús Aguila-León ◽  
David Alfonso-Solar

Heat stress can affect negatively human performance, behavior and even health, therefore, mean radiant temperature (MRT) and wet-bulb globe temperature (WBGT) measurement and monitoring should be obtained for any environment in which people are constantly exposed. The aim of this work is to compare the globe thermometer temperature (tg), used for calculating both MTR and   WBGT, using a smaller globe compared to a standardized diameter. For such purpose, a prototype has been designed. The device consists of an Arduino MEGA board, three temperature sensors, two black globes (Copper globe, matt black painted) and an anemometer. As an effort to use a device with a globe easier to handle in a real measuring device, a 9 cm diameter globe has been used which has a smaller diameter than a standardized one (15 cm); the third temperature sensor is used to measure the air temperature. MRT monitoring tests were carried out using the proposed prototype,  collected data were compared between the smaller and the standardized diameter globes measurements according to UNE EN ISO 7723 and NTP 322 recommendations. Results of this work show that it is possible to use a smaller diameter globe in a heat stress monitor, with an acceptable margin of error compared to a standardized size globe.


Author(s):  
David Alfonso-Solar ◽  
Paula Bastida-Molina ◽  
Lina Montuori ◽  
Carlos Vargas-Salgado

In this paper, it is presented preliminary results of a methodology for thermal comfort monitoring and evaluation in urban areas based on local metering of ambient conditions and Rayman model application. In the framework of GROWGREEN European project it was installed six monitoring stations for data acquisition of air temperature, relative humidity, wind speed, solar radiation and black globe temperature. Data of first 5 months of monitoring and modelling of one location with Rayman model to calculate  PET (physiological equivalent temperature) is presented. Based on PET it was calculated the percentage of hours with thermal comfort per month, and it was made a comparison between PET and black globe temperature (GT) in order to evaluate the suitability of GT as a single, low cost and robust indicator of thermal comfort in urban areas.


2019 ◽  
Vol 85 ◽  
pp. 102408 ◽  
Author(s):  
Thieres George Freire da Silva ◽  
Girlene Cordeiro Lima Santos ◽  
Ana Maria Cabral Duarte ◽  
Sílvia Helena Nogueira Turco ◽  
José Francisco da Cruz Neto ◽  
...  

2019 ◽  
Vol 34 (2) ◽  
pp. 230-240 ◽  
Author(s):  
Silvia Noelly Ramos de Araújo ◽  
José Pinheiro Lopes Neto ◽  
José Wallace Barbosa do Nascimento ◽  
Fernanda Fernandes de Melo Lopes ◽  
Maria Luíza de Souza Rezende

CONFORTO TÉRMICO E DESEMPENHO DE LEITÕES CRIADOS EM GAIOLAS ENRIQUECIDAS COM PISO DE RESÍDUOS DE EVA (ETILENO-ACETATO DE VINILA)   SILVIA NOELLY RAMOS DE ARAÚJO1, JOSÉ PINHEIRO LOPES NETO2, JOSÉ WALLACE BARBOSA DO NASCIMENTO3, FERNANDA FERNANDES DE MELO LOPES4, MARIA LUIZA DE SOUZA REZENDE5   Engenharia Agrícola, Universidade Federal de Campina Grande, Rua Aprígio Veloso, 882 – Universitário, 58429-900, Campina Grande, Paraíba, Brasil, [email protected]; [email protected]; [email protected]; [email protected]; [email protected].   RESUMO: Objetivou-se analisar o conforto térmico de leitões na fase de creche, mantidos em instalações com piso de placas de resíduos EVA, utilizadas para reduzir a transferência de calor dos animais para a superfície de contato, utilizando-se 24 leitões desmamados, com idade média de 23 + 2 dias, distribuídos em 8 baias, utilizando-se dois tipos de pisos: tratamento 1- Placas de EVA + piso plástico vazado e o tratamento 2- piso plástico vazado. O delineamento experimental foi inteiramente casualizado (DIC) e a comparação entre as médias através do teste de Tukey (P<0,05). A caracterização do ambiente térmico foi realizada por meio do registro da temperatura do ar, umidade relativa, temperatura de globo negro, luminosidade e velocidade do vento. Para a análise do conforto térmico proporcionado pelos pisos utilizou-se os índices de conforto térmico (temperatura de globo negro e umidade e a carga térmica de radiação), o mapeamento térmico superficial (pisos e leitões) e o desempenho produtivo dos animais. Os resultados indicaram que, as placas sobre o piso mostraram ser eficiente na redução da transferência de calor sensível entre o piso-leitão, o que tornou o aquecimento mais eficaz para os animais.   Palavras-chaves: conforto térmico, creche suína, material alternativo, piso plástico.   THERMAL COMFORT AND PERFORMANCE OF PIGLETS CREATED IN ENRICHED CAGES WITH EVA WASTE FLOOR (VINYL ETHYLENE ACETATE)   ABSTRACT: The aim of this study was to analyze the thermal comfort of piglets in nursery phase, maintained in systems with EVA waste plates floor, used to reduce the animal heat transfer to the contact surface, using 24 weaned piglets, average age 23 + 2 days, distributed in 8 bays, using two types of floors: treatment 1: EVA plates + leaked plastic floor and treatment 2: leaked plastic floor. The experimental design was completely randomized (CRD) and the means were compared using Tukey's test (P<0.05). The characterization of the thermal environment was performed by recording the air temperature, relative humidity, black globe temperature, luminosity and wind speed. Thermal comfort indices (black globe temperature and humidity and thermal radiation load), thermal thermal mapping (floors and piglets) and the productive performance of animals were used to analyze the thermal comfort provided by the floors. The results indicated that the boards on the floor were shown to be efficient in reducing the transfer of sensible heat between the floor-piglet, which made heating more effective for the animals.   Keywords: thermal comfort, nursery, alternative material, plastic floor.


Sign in / Sign up

Export Citation Format

Share Document