The cooling effect of a spray fan in an indoor hot environment

2020 ◽  
pp. 1420326X2091436
Author(s):  
Xiaojing Meng ◽  
Yihang Lv ◽  
Honggang Yang ◽  
Yi Wang

The aim of this study is to evaluate the cooling effect of a spray fan in an indoor hot environment. An experimental workplace with a thermal environment of high temperature and radiation intensity was set up. The hot environment of the experimental workplace could not meet occupational health requirements when the heat source temperature exceeded 150°C. The effects of air velocity and relative humidity on the natural wet bulb temperature, black globe temperature and wet bulb globe temperature (WBGT) were investigated. The maximum reduction of the WBGT was about 1.7°C, with an air velocity increase by 1 m/s. There was a notable cooling effect on the hot environment for low air velocities (e.g. 0–2 m/s), while the cooling effect only increased slightly for high air velocity (e.g. 2–5 m/s). We also found that the indoor WBGT declined by 0.2–0.8°C when the relative humidity was increased by about 10%. These results may provide guidance for reducing heat stress in industrial hot environment.

2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.


2017 ◽  
Vol 2017 ◽  
pp. 1-13 ◽  
Author(s):  
Jianglong Zhen ◽  
Jun Lu ◽  
Guangqin Huang ◽  
Liyue Zeng ◽  
Jianping Lin ◽  
...  

In order to study the characteristics of indoor thermal environment in the airport terminal in Tibet Plateau with radiant floor heating in winter, a field measurement of the indoor thermal environment was conducted in Lhasa Gonggar Airport terminal 2. First, the unique climate characteristics in Tibet Plateau were analyzed through comparison of meteorological parameters in Beijing and Lahsa. The thermal environment in the terminal was divided into outer zone and inner zone as well as south zone and north zone. Thermal environment parameters including air temperature, black globe temperature, relative humidity in each zone, and inner surface temperature of envelope were measured and analyzed. Meanwhile, temperature and relative humidity in the vertical direction were measured. In addition, PMV and PPD were calculated for evaluating the thermal environment in the terminal. The findings can provide guidance for the design and regulation of thermal environment in terminals in Tibet Plateau in China.


2020 ◽  
pp. bmjmilitary-2020-001551
Author(s):  
Patricia Falconer Hall ◽  
J Blackadder-Coward ◽  
H Pynn

IntroductionHeat illness among the UK Armed Forces is usually exertional, and therefore preventable, yet the incidence has not reduced since 2011. JSP 539 explicitly states that wet bulb globe temperature (WBGT) should be measured ‘at the location of greatest heat risk’, not ‘that of most convenience’. A handheld WBGT tracker used at point-of-exertion could reduce this incidence if proven to be as accurate as the current in-service device.MethodsLongitudinal observational comparison and equipment feasibility study of the Kestrel 5400 and QUESTemp 34 (QT-34) in worldwide firm base and deployed UK Armed Forces locations. The locations chosen were Kenya, South Sudan, Belize, Tidworth, Aldershot and Brecon. Paired data points of WBGT readings were collected from November 2017 to August 2018 in all weather conditions.ResultsWBGT readings were comparable between the QT-34 and Kestrel 5400 across the UK and overseas. In addition, there was no change in accuracy between readings taken from the Kestrel 5400 when tripod-mounted and handheld. The Kestrel was easy to set up and far less susceptible to resupply or power supply limitations, as it requires no user input for wet bulb temperature, and runs on AA batteries.ConclusionThis equipment feasibility study has shown that the Kestrel 5400 gives an acceptable accuracy and is easier to use than the QT-34. The authors recommend that the Kestrel 5400 is introduced as an adjunct to the QT-34, and its use within the military setting monitored through ongoing comparative data collection in a large-scale proof-of-concept study.


2019 ◽  
Vol 111 ◽  
pp. 06054
Author(s):  
Noriko Umemiya ◽  
Kurumi Yamagata ◽  
Tomohiro Kobayashi

Relations between bedroom thermal environment changes and subjective sleep quality and thermal comfort were surveyed for 63 apartment occupants during midsummer in Osaka. Changes of Wet Bulb Globe Temperature (WBGT) of 123 air-conditioned and 41 naturally ventilated nights were compared. 1) For air-conditioned bedrooms, sleep quality was better for smaller changes of WBGT from the beginning of sleep and for faster changes of WBGT to constant from the beginning of sleep. 2) For naturally ventilated bedrooms, a) WBGT increased from the beginning of sleep and decreased toward the end of sleep for higher sleep quality nights. However, WBGT decreased from the beginning of sleep and increased toward the end of sleep for lower sleep quality nights. b) The WBGT change was smaller for thermally comfortable nights.


2010 ◽  
Vol 39 (3) ◽  
pp. 685-694 ◽  
Author(s):  
Wander de Souza ◽  
Orlando Rus Barbosa ◽  
Jair de Araújo Marques ◽  
Marco Aurélio Teixeira Costa ◽  
Eliane Gasparino ◽  
...  

The aim of this work was to verify if the presence of trees and its height in formed silvipastoral systems with eucalyptus planted in rank can modify the microclimate and improve the environment for bovine raising during the day in summer. It was evaluated the microclimate of the environment in formed silvipastoral systems in rank of eucalyptus with 8 m, 18 m and 28 meters of height, compared to a system no shade in the summer. The experimental design was a split plot with six hour time in sub parcels. The systems are made up of parcels and the months as block in four replications and the interaction hour × system. The air temperature, black globe temperature, relative humidity and wind speed were observed to create the following indexes for thermal comfort: temperature-humidity index; black globe-humidity index; heat load index and the radiant thermal load. Excepted for the relative humidity, there was interaction for time × system for all variables and indexes. Interaction occurred for: air temperature at 10 a.m. and 6 p.m.; wind speed from 8 a.m. to 4 p.m.; temperature humidity index at 10 a.m. and 12 p.m.; black globe temperature, black globe humidity index, heat load index, and radiant thermal load at all the hours. During the summer, the system with shade of 28 m trees had the lowest average of black globe temperature; wind speed; black globe humidity index; radiant thermal load index; and heat load index. There was a reduction of wind speed average in systems 8 m, 18 m and 28 m trees in, respectively, 20.7; 50.0 and 48.0% in relation to no shade system; however it was not proportional to the height, with influence of the rank porosity and pantries height. Nevertheless, for radiant thermal load index the reduction was proportional to the height of the trees with 10.24; 12.49 and 20.76%, respectively, for 8 m, 18 m and 28 meters of height. There was a reduction of the thermal stress in the environment due to the presence of trees, being the heat load index thermal the index that better demonstrated the effect, despite of not being proportional to the rank height.


2020 ◽  
pp. bjsports-2020-103048
Author(s):  
Sebastien Racinais ◽  
Marine Alhammoud ◽  
Nada Nasir ◽  
Roald Bahr

ObjectivesTo analyse 11 years of FIVB heat stress-monitoring data to determine the relative influence of the different environmental parameters in increasing the likelihood of a heat-related medical time-out (MTOheat).MethodsA total of 8530 matches were recorded. The referee measured air temperature, black globe temperature, relative humidity and wet-bulb globe temperature (WBGT) before the matches, and registered the MTOheat. The absolute humidity was computed at posteriori.ResultsThere were 20 MTOheat cases, but only 3 resulted in forfeiting the match. MTOheat incidence was not statistically impacted by sex (p=0.59). MTOheat cases were more prevalent during the games played in Asia during the 4th quarter of the year (p<0.001). Two cases of MTOheat experienced diarrhoea or gastroenteritis during the 5 preceding days; both of them forfeited the match. A principal component analysis showed a specific environmental profile for the matches with MTOheat. They occurred at higher WBGT, temperatures and absolute humidity (p<0.001), but with a lower relative humidity (p=0.027).ConclusionsThe current data showed that an increase in ambient or black globe temperature, but not relative humidity, increased the risk of a MTOheat; but that the absolute risk remained low in elite beach volleyball players. However, suffering or recovering from a recent illness may represent a risk factor for a MTOheat to lead to player forfeit.


2021 ◽  
Author(s):  
Olivia Cahill ◽  
Andrew Grundstein ◽  
Christian Walker ◽  
Earl Cooper

&lt;p&gt;Across the globe, exposure to environmental heat stress may impose increased health and safety hazards to active populations such as athletes and workers. Monitoring heat stress is a key component of a well-designed heat mitigation policy. Yet, the cost of several hand-held heat stress sensors may pose a financial barrier for use in many circumstances. Numerous areas, however, have existing networks of weather stations that could potentially be incorporated into monitoring heat stress. Currently, the Japanese Ministry of the Environment has set up a network of weather stations across the city to monitor environmental conditions in preparation of the 2021 Tokyo Olympic and Paralympic games. Our research question asks how representative are the values recorded at local weather stations (often located over a natural surface) to playing field conditions with various surfaces and microclimate conditions. In the U.S. the WeatherSTEM network has over 600 stations scattered across the country and measures a suite of variables relevant to heat stress including air temperature, humidity, wind speed, solar radiation and models the wet bulb globe temperature (WBGT) values. This study will compare measurements from a local WeatherSTEM station with on-site measurements taken over three different playing surfaces (grass, synthetic turf, and hardcourt tennis) in a humid subtropical climate in Athens, Georgia. U.S. It will also compare WBGT values computed using different models. Our results may provide insight not only for sports but also for the workplace which take place over various surface types and environments.&lt;/p&gt;


2013 ◽  
Vol 17 (2) ◽  
pp. 387-396 ◽  
Author(s):  
Ahmad Ismail ◽  
Kumar Karagaratnan ◽  
Kumaran Kadirgama

This paper discusses the findings of thermal comfort assessment at Malaysian automotive industry. Nine critical workstations were chosen as subjects for the study in order to determine the thermal comfort among workers at Malaysian automotive industry. The human subjects for the study comprises of the operators from tire receiving, dashboard assembly, drum tester, body assembly, seat assembly, door check assembly, stamping workstation, engine sub assembly and paint shop of the factory. The environmental factors such as Wet Bulb Globe Temperature (WBGT), relative humidity, air velocity, illuminance were measured using BABUC A apparatus and Thermal Comfort Measurement equipment. Through questionnaire survey, the demographic data of subjects and their perceptions on thermal comfort at each workstation were assessed based on ISO Standard 7730 and thermal sensation scale using Predicted Mean Vote (PMV). Then, Predicted Percentage of Dissatisfied (PPD) is used to estimate the thermal satisfaction of occupants. The results indicated that most of the workstations of the automotive industry are considered as uncomfortable. Tire receiving station is considered having better working environment compared to other stations with lowest PMV index of 1.09 to 1.41 and PPD of 46%. Meanwhile, the engine sub assembly station and paint shop of assembly are considered the worst thermal environment with the PMV index values ranging between 2.1 to 2.9 and PPD values of 81% to 99%. Therefore, these two workstations are considered not comfortable because the thermal sensation scale is warm and almost hot.


Sign in / Sign up

Export Citation Format

Share Document