us elastography
Recently Published Documents


TOTAL DOCUMENTS

59
(FIVE YEARS 14)

H-INDEX

15
(FIVE YEARS 1)

Radiology ◽  
2021 ◽  
pp. 203893
Author(s):  
Aileen O'Shea ◽  
Theodore T. Pierce

Radiology ◽  
2021 ◽  
pp. 202232
Author(s):  
Uday Kumar Marri ◽  
Prasenjit Das ◽  
Shalimar ◽  
Mani Kalaivani ◽  
Deep Narayan Srivastava ◽  
...  

2020 ◽  
pp. 000313482095149
Author(s):  
Mohamed Abdelgawad ◽  
Hosam Shalaby ◽  
Mounika Akkera ◽  
Yasmine Rashad ◽  
Lee Grace ◽  
...  

Objectives To evaluate the safety and efficacy of percutaneous ethanol ablation (PEA) on indeterminate thyroid nodules (Bethesda III and IV) based on ultrasound (US) elastography by assessing the volume reduction rate (VRR), relative reduction in size, resolution of compressive symptoms, and post-procedural complications. Materials and Methods This is a retrospective cohort study of all thyroid nodules treated with PEA by a single surgeon at a North American tertiary referral center. Study variables included demographics, nodule characteristics, Bethesda classification, US elastography, presence of compressive symptoms, thyroid function, and post-procedural complications. Relative volume reductions and VRR were calculated at 3- and 6-month follow-ups. Results Thirty-four thyroid nodules were evaluated in 22 patients. All thyroid nodules underwent a fine needle aspiration prior to PEA. After 6 months, 45% of all thyroid nodules exhibited a VRR of ≥50%. A significant VRR was achieved in the soft thyroid nodules at 6 months (42.15% ± 31), compared to the stiff nodules with 30.92% ± 91.53, P < .05. Post-PEA thyroid stimulating hormone levels did not significantly change after the procedure. Compressive symptoms resolved in all 5 patients who reported it. One patient developed transient vocal cord paresis that resolved in 3 months. Discussion To the best of our knowledge, this is the largest series of PEA for thyroid nodules in North America. Ultrasound elastography is a useful adjunct in predicting the success of PEA for nonmalignant thyroid nodules. Percutaneous ethanol ablation is both a safe and effective alternative to surgery for relief of compressive symptoms in select patients.


2020 ◽  
pp. 028418512096142
Author(s):  
Yasemin Altıntas ◽  
Mehmet Bayrak ◽  
Ömer Alabaz ◽  
Medih Celiktas

Background Ultrasound (US) elastography has become a routine instrument in ultrasonographic diagnosis that measures the consistency and stiffness of tissues. Purpose To distinguish benign and malignant breast masses using a single US system by comparing the diagnostic parameters of three kinds of breast elastography simultaneously added to B-mode ultrasonography. Material and Methods A total of 163 breast lesions in 159 consecutive women who underwent US-guided core needle biopsy were included in this prospective study. Before the biopsy, the lesions were examined with B-mode ultrasonography and strain (SE), shear wave (SWE), and point shear wave (STQ) elastography. The strain ratio was computed and the Tsukuba score determined. The mean elasticity values using SWE and STQ were computed and converted to Young’s modulus E (kPa). Results All SE, SWE, and STQ parameters showed similar diagnostic performance. The SE score, SE ratio, SWEmean, SWEmax, STQmean, and STQmax yielded higher specificity than B-mode US alone to differentiate benign and malignant masses. The sensitivity of B-mode US, SWE, and STQ was slightly higher than that of the SE score and SE ratio. The SE score, SE ratio, SWEmean, SWEmax, STQmean, and STQmax had significantly higher positive predictive value and diagnostic accuracy than B-mode US alone. The area under the curve for each of these elastography methods in differentiating benign and malignant breast lesions was 0.93, 0.93, 0.98, 0.97, 0.98, and 0.96, respectively; P<0.001 for all measurements. Conclusion SE (ratio and score), SWE, and STQ had higher diagnostic performance individually than B-mode US alone in distinguishing between malignant and benign breast masses.


Author(s):  
Ernst Jung ◽  
Vanessa Hösl ◽  
Sarah von Fraunberg ◽  
Friedrich Jung ◽  
Lukas Prantl

BACKGROUND: Capsular contractures around breast implants usually develop leading to pain and aesthetically inadequate results and ultimately often requires the replacement of the implants. Textured silicone implants are the most commonly placed implant, but polyurethane-coated implants are increasingly being used in an attempt to ameliorate the long-term complications associated with implant insertion. AIM: Capsular contracture is traditionally classified using the Baker scale, a subjective classification system based upon clinical findings. Aim of this study was to evaluate the association between pain due capsular contraction, Baker Score and different techniques of US elastography. MATERIAL AND METHODS: Patients were contacted who had undergone an implant replacement due to capsular contracture. Inclusion criterion was the re-implantation of a PU-coated implant. In the third year after changing the implant a follow-up examination was performed in 16 patients with 23 implants. A conventional examination with anamnesis, tactile and visual findings to obtain a Baker score, and ultrasound examinations including shear wave elastography, ARFI and compound elastography were performed. In addition, pain was evaluated using a visual analogue scale (VAS). RESULTS: The pain data showed a significant improvement (before implant exchange: 4.1±2.8 score points) with significance in favor of the current state (1.7±1.0 pain score points; p = 0.002). All patients suffered from less or no pain three years after exchange of the implant. Pain values and elastography (ARFI values) correlated well (r = 0,873), with increasing Baker score the ARFI values increased. US elastography evaluations can locally determine tissue density but correlate only to a limited extent with the test findings according to Baker. US elastography values of mammary gland tissue without implant did not differ from mammary gland tissue around implants. CONCLUSION: Preoperative Baker scores prior to exchange and the current Baker scores at the follow-up showed significantly lower score points three years after exchange of the implants. Ultrasound elastography seems to be an objective classification of capsular fibrosis. These first results motivate to initiate a prospective multicenter investigation.


2020 ◽  
pp. 028418512094848
Author(s):  
Jisun Hwang ◽  
Hee Mang Yoon ◽  
Kyung Mo Kim ◽  
Seak Hee Oh ◽  
Jung-Man Namgoong ◽  
...  

Background Validated non-invasive examinations are necessary to monitor liver fibrosis in children with biliary atresia (BA) after the Kasai procedure. Purpose To evaluate the diagnostic accuracy of two-dimensional shear wave elastography (2D-SWE), transient elastography (TE), and the serologic biomarkers of aspartate transaminase-to-platelet ratio index (APRI) and Fibrosis-4 (FIB-4) score for evaluating native liver fibrosis in children with BA. Material and Methods We retrospectively reviewed same-day 2D-SWE and TE liver stiffness (LS) measurements of 63 patients with BA who underwent the Kasai procedure. The APRI and FIB-4 score were computed. Hepatic fibrosis was categorized into three clinical categories based on the ultrasound (US) hepatic morphology and clinical manifestations of liver cirrhosis: I, pre-cirrhotic liver state (n = 15); II, US and/or clinical signs of liver cirrhosis with compensated liver function (n = 27); and III, liver cirrhosis with decompensated liver function (n = 21). We compared area under the receiver operating characteristic curve (AUC) data among 2D-SWE, TE, APRI, and FIB-4 score. Combined evaluation of serologic fibrosis indices and US elastography was conducted and AUCs of combinations were analyzed. Results 2D-SWE, TE, APRI, and FIB-4 score showed good to excellent diagnostic accuracy for differentiating clinical categories (AUCs 0.779–0.955). AUC values were significantly increased after adding TE to FIB-4 score for detecting liver cirrhosis ( P = 0.02). Conclusion 2D-SWE, TE, APRI, and FIB-4 score are accurate non-invasive markers for monitoring native liver fibrosis in patients with BA. Combined use of serologic markers and US elastography could yield more accurate diagnoses of liver fibrosis than serologic markers alone.


2020 ◽  
Vol 17 (2) ◽  
Author(s):  
Kadir Oymen Hancerliogullari

Background: One of the most important urologic emergencies is testicular torsion in children. Elastography is as an objective method in diagnosis and treatment of testicular torsion, with grayscale and colored images. Our study presents an original framework, which may guide certain research and practices in this field. Objectives: The aim of this study was to evaluate the effectiveness of ultrasound (US)-elastography for the diagnostic performance of testicular torsion. Materials and Methods: In this experimental study, 16 male white New Zealand rabbits of the same weight and age were selected and divided into two groups. In group I, the right testicle was fixed, and in group II, the right testicle underwent 720° torsion in a counterclockwise direction and fixed. Following 1 and 2 hours of ischemia, measurements of the right and left testicles were performed simultaneously. The left testicle was measured again after 24 hours in order to better observe the changes that right testicular ischemia might have had on the left testicle. Results: A statistically significant increase was detected in the elastography values of the right testicle at 1, 2, and 24 hours (P < 0.05). Elastography values were significantly increased in the left testicle after 24 hours (P < 0.05). The elastographic measurement values of the testicular tissue increased significantly with the increase in the duration of ischemia. Conclusion: With the width of its imaging window and healthy evaluation opportunity, elastography is a method in determining tissue stiffness of unilateral and contralateral testicular structures. In this study, the efficacy of elastography was evaluated. As a future research, further studies are needed to evaluate the elastography values in epididmo-orchitis and other causes of acute scrotum.