primary break
Recently Published Documents


TOTAL DOCUMENTS

27
(FIVE YEARS 2)

H-INDEX

10
(FIVE YEARS 1)

PLoS ONE ◽  
2020 ◽  
Vol 15 (8) ◽  
pp. e0236063
Author(s):  
Kendra Shrestha ◽  
James Van Strien ◽  
Narinder Singh ◽  
Kiao Inthavong

Energies ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2890 ◽  
Author(s):  
Sparacino ◽  
Berni ◽  
d’Adamo ◽  
Krastev ◽  
Cavicchi ◽  
...  

The scientific literature focusing on the numerical simulation of fuel sprays is rich in atomization and secondary break-up models. However, it is well known that the predictive capability of even the most diffused models is affected by the combination of injection parameters and operating conditions, especially backpressure. In this paper, an alternative atomization strategy is proposed for the 3D-Computational Fluid Dynamics (CFD) simulation of Gasoline Direct Injection (GDI) sprays, aiming at extending simulation predictive capabilities over a wider range of operating conditions. In particular, attention is focused on the effects of back pressure, which has a remarkable impact on both the morphology and the sizing of GDI sprays. 3D-CFD Lagrangian simulations of two different multi-hole injectors are presented. The first injector is a 5-hole GDI prototype unit operated at ambient conditions. The second one is the well-known Spray G, characterized by a higher back pressure (up to 0.6 MPa). Numerical results are compared against experiments in terms of liquid penetration and Phase Doppler Anemometry (PDA) data of droplet sizing/velocity and imaging. CFD results are demonstrated to be highly sensitive to spray vessel pressure, mainly because of the atomization strategy. The proposed alternative approach proves to strongly reduce such dependency. Moreover, in order to further validate the alternative primary break-up strategy adopted for the initialization of the droplets, an internal nozzle flow simulation is carried out on the Spray G injector, able to provide information on the characteristic diameter of the liquid column exiting from the nozzle.


Author(s):  
RATHESAN RAVENDRAN ◽  
BENNY ENDELT ◽  
JESPER DE CLAVILLE CHRISTIANSEN ◽  
PETER JENSEN

2014 ◽  
Vol 764 ◽  
pp. 95-132 ◽  
Author(s):  
A. Kourmatzis ◽  
A. R. Masri

AbstractAir-assisted primary atomization is investigated in a configuration where liquid is injected in a turbulent gaseous jet flow both within as well as outside of the potential core. Cases are studied where the injection point is moved within the flow to maintain a range of constant gaseous mean velocities but changing local fluctuating velocity root-mean-square (r.m.s.) levels. Over a range of mean conditions, this allows for a systematic understanding of both the effects of gas-phase turbulence and mean shear on primary break-up independently. Extensive data is obtained and analysed from laser Doppler anemometry/phase Doppler anemometry, high-speed microscopic backlit imaging and advanced image processing. It is found that the ratio of the turbulent Weber number $\mathit{We}^{\prime }$ to the mean Weber number $\mathit{We}$ is a relevant parameter as is the turbulence intensity. The primary break-up length is found to be heavily influenced not only by the mean velocity, but also by the turbulence level and the mass fuel to air ratio. Above a particular threshold intensity level the break-up time changes in proportion to the change in the integral time scale of the flow. In addition, it is found that regardless of diameter and turbulent flow conditions at the liquid jet, the final size of ligaments converges to a value which is of the order of the measured primary instability wavelength (${\it\lambda}_{1}$). In contrast, cases of different turbulence intensity show the mean of droplet sizes diverging as the spray is advected downstream and this is because droplets are generated from ligaments, the latter of which are subjected both to Rayleigh–Taylor instabilities and turbulent fluctuations. This contribution, for the first time, examines the theoretical applicability of the Rayleigh–Taylor instability in flows where the turbulence is substantial with respect to the mean flow. It is shown that for high turbulence intensities a full theoretical reconstruction of the measured final droplet size distribution is possible from a probability density function of model Rayleigh–Taylor wavelengths (${\it\lambda}_{RT}$). In agreement with the literature (Varga et al. J. Fluid Mech., vol. 497, 2003, pp. 405–434), mean droplet sizes are found to be equal to a mean theoretical Rayleigh–Taylor wavelength normalized by a particular constant value. This, however, is only true for local turbulence intensities less than ${\sim}25\,\%$, or for ratios of the turbulent Weber number to mean Weber number ($\mathit{We}^{\prime }/\mathit{We}$) of less than ${\sim}6\,\%$. Above this, the normalization value is no longer constant, but increases with $\mathit{We}^{\prime }/\mathit{We}$. Finally, the instability wavelengths can be used as part of an approximation that estimates the total number of objects formed after break-up, where the object number is found to be dictated by a balance of both mean flow conditions and local turbulence.


Author(s):  
Filippo Coletti ◽  
Michael J. Benson ◽  
Alexander L. Sagues ◽  
Benjamin H. Miller ◽  
Rebecca Fahrig ◽  
...  

In order to design a spraying system with the desired characteristics, the atomization process has to be understood in detail, including the primary break-up of the liquid core. Accurate prediction of primary break-up is a major barrier to computer-based analysis of spray combustion. The development of models is hindered by the lack of validation data in a region where the fluid is dense, and optical access is therefore limited. The present experimental study is aimed at probing the spray structure by means of X-ray computed tomography (CT). A full-cone atomizer (0.79 mm orifice diameter) spraying in air at ambient pressure is investigated as a proof of concept. A mixture of water and iodine is used as the working fluid, providing elevated X-ray absorption and therefore improved signal-to-noise ratio. Several hundreds of X-ray projections are acquired as the spraying atomizer is rotated in front of the detector. Standard software for medical imaging is used to reconstruct the three-dimensional time-averaged distribution of liquid mass fraction in the full field of view, from the intact liquid core to the dilute spray region. A spatial resolution of 0.6 mm is obtained along the spraying direction, while the resolution is 0.3 mm in the other two directions. Significant asymmetries in the structure of the spray are revealed.


2013 ◽  
Vol 23 (11) ◽  
pp. 957-980 ◽  
Author(s):  
Francois-Xavier Demoulin ◽  
Julien Reveillon ◽  
B. Duret ◽  
Zakaria Bouali ◽  
P. Desjonqueres ◽  
...  

2012 ◽  
Vol 108 (4) ◽  
pp. 783-792 ◽  
Author(s):  
N. Zeoli ◽  
H. Tabbara ◽  
S. Gu

Sign in / Sign up

Export Citation Format

Share Document