scholarly journals Flow rate dictates permeability enhancement during fluid pressure oscillations in laboratory experiments

2015 ◽  
Vol 120 (4) ◽  
pp. 2037-2055 ◽  
Author(s):  
Thibault Candela ◽  
Emily E. Brodsky ◽  
Chris Marone ◽  
Derek Elsworth
Author(s):  
Corine Meuleman ◽  
Frank Willems ◽  
Rick de Lange ◽  
Bram de Jager

Surge is measured in a low-speed radial compressor with a vaned diffuser. For this system, the flow coefficient at surge is determined. This coefficient is a measure for the inducer inlet flow angle and is found to increase with increasing rotational speed. Moreover, the frequency and amplitude of the pressure oscillations during fully-developed surge are compared with results obtained with the Greitzer lumped parameter model. The measured surge frequency increases when the compressor mass flow is throttled to a smaller flow rate. Simulations show that the Greitzer model describes this relation reasonably well except for low rotational speeds. The predicted amplitude of the pressure rise oscillations is approximately two times too small when deep surge is met in the simulations. For classic surge, the agreement is worse. The amplitude is found to depend strongly on the shape of the compressor and throttle characteristic, which are not accurately known.


Author(s):  
Nasser Seraj Mehdizadeh ◽  
Nozar Akbari

Lean premixed combustion is widely used in recent years as a method to achieve the environmental standards with regard to NOx emission. In spite of the mentioned advantage, premixed combustion systems, with equivalence ratios less than one, are susceptible to the combustion instability. To study the lean combustion instability, by experiments, one premixed combustion setup, equipped with reactant supplying system, is designed and manufactured in Amirkabir University of Technology. In this research, gaseous propane is introduced as fuel and several experiments are performed at nearly atmospheric pressure, with equivalence ratios within the range of 0.7 to 1.5. In this experiments fuel mass flow rate is varied between 2 and 4 gr/s. Unstable operating condition has been observed in combustion chamber when equivalence ratio is less than one. To distinguish the combustion instability for various operating conditions, probability density functions, spectral diagrams, and space distribution of pressure oscillations, along with Rayleigh Criterion, are utilized. Accordingly, effect of equivalence ratio on stabilizing the unstable combustion system is investigated. Moreover, convective delay time is calculated for all experiments and the results are compared with Rayleigh Criterion. This comparison has shown good agreement the experimental results and Rayleigh Criterion. Finally, stability limits are identified based on inlet mass flow rate and equivalence ratio.


2021 ◽  
pp. 1-10
Author(s):  
Yongsheng Liu ◽  
Xing Qin ◽  
Yuchen Sun ◽  
Zijun Dou ◽  
Jiansong Zhang ◽  
...  

Abstract Aiming at the oscillation drag reduction tool that improves the extension limit of coiled tubing downhole operations, the fluid hammer equation of the oscillation drag reducer is established based on the fluid hammer effect. The fluid hammer equation is solved by the asymptotic method, and the distribution of fluid pressure and flow velocity in coiled tubing with oscillation drag reducers is obtained. At the same time, the axial force and radial force of the coiled tubing caused by the fluid hammer oscillator are calculated according to the momentum theorem. The radial force will change the normal contact force of the coiled tubing which has a great influence on frictional drag. The results show that the fluid flow rate and pressure decrease stepwise from the oscillator position to the wellhead position, and the fluid flow rate and pressure will change abruptly during each valve opening and closing time. When the fluid passes through the oscillator, the unit mass fluid will generate an instantaneous axial tension due to the change in the fluid velocity, thereby converting the static friction into dynamic friction, which is conducive to the extend limit of coiled tubing.


Proceedings ◽  
2019 ◽  
Vol 48 (1) ◽  
pp. 26
Author(s):  
Riccardo Zarbo ◽  
Valentina Marsili ◽  
Stefano Alvisi ◽  
Marco Franchini

Pressure reducing valves (PRVs) effectiveness for water distribution networks’ (WDNs’) optimal pressure management is proven, but problems and operational limitations have been highlighted by some recent studies. In this work, the functioning of a piston-actuated pressure reducing valve (PA-PRV), subjected to low flow regimes, is investigated by means of a laboratory test set. The results obtained highlight that the PA-PRV tends not to respect the imposed set-point value, and can present an unstable behaviour, characterised by significant pressure oscillations under some flow-rate conditions.


2020 ◽  
Vol 223 (3) ◽  
pp. 1481-1496
Author(s):  
Elif Cihan Yildirim ◽  
Kyungjae Im ◽  
Derek Elsworth

SUMMARY Mechanisms controlling fracture permeability enhancement during injection-induced and natural dynamic stressing remain unresolved. We explore pressure-driven permeability (k) evolution by step-increasing fluid pressure (p) on near-critically stressed laboratory fractures in shale and schist as representative of faults in sedimentary reservoirs/seals and basement rocks. Fluid is pulsed through the fracture with successively incremented pressure to first examine sub-reactivation permeability response that then progresses through fracture reactivation. Transient pore pressure pulses result in a permeability increase that persists even after the return of spiked pore pressure to the null background level. We show that fracture sealing is systematically reversible with the perturbing pressure pulses and pressure-driven permeability enhancement is eminently reproducible even absent shear slip and in the very short term (order of minutes). These characteristics of the observed fracture sealing following a pressure perturbation appear similar to those of the response by rate-and-state frictional healing upon stress/velocity perturbations. Dynamic permeability increase scales with the pore pressure magnitude and fracture sealing controls the following per-pulse permeability increase, both in the absence and presence of reactivation. However, initiation of the injection-induced reactivation results in a significant increase in the rate of permeability enhancement (dk/dp). These results demonstrate the role of frictional healing and sealing of fractures at interplay with other probable processes in pore pressure-driven permeability stimulation, such as particle mobilization.


2018 ◽  
Vol 180 ◽  
pp. 02046
Author(s):  
KristÍna Kovalčíková ◽  
Martin Slavík ◽  
Katarína Bachratá ◽  
Hynek Bachratý ◽  
Alžbeta Bohiniková

In this work, we examine the volumetric flow rate of microfluidic devices. The volumetric flow rate is a parameter which is necessary to correctly set up a simulation of a real device and to check the conformity of a simulation and a laboratory experiments [1]. Instead of defining the volumetric rate at the beginning as a simulation parameter, a parameter of external force is set. The proposed hypothesis is that for a fixed set of other parameters (topology, viscosity of the liquid, …) the volumetric flow rate is linearly dependent on external force in typical ranges of fluid velocity used in our simulations. To confirm this linearity hypothesis and to find numerical limits of this approach, we test several values of the external force parameter. The tests are designed for three different topologies of simulation box and for various haematocrits. The topologies of the microfluidic devices are inspired by existing laboratory experiments [3 - 6]. The linear relationship between the external force and the volumetric flow rate is verified in orders of magnitudes similar to the values obtained from laboratory experiments.


2016 ◽  
Vol 801 ◽  
pp. 65-90 ◽  
Author(s):  
Roiy Sayag ◽  
Jerome A. Neufeld

We study the propagation of viscous gravity currents over a thin porous substrate with finite capillary entry pressure. Near the origin, where the current is deep, propagation of the current coincides with leakage through the substrate. Near the nose of the current, where the current is thin and the fluid pressure is below the capillary entry pressure, drainage is absent. Consequently the flow can be characterised by the evolution of drainage and fluid fronts. We analyse this flow using numerical and analytical techniques combined with laboratory-scale experiments. At early times, we find that the position of both fronts evolve as $t^{1/2}$, similar to an axisymmetric gravity current on an impermeable substrate. At later times, the growing effect of drainage inhibits spreading, causing the drainage front to logarithmically approach a steady position. In contrast, the asymptotic propagation of the fluid front is quasi-self-similar, having identical structure to the solution of gravity currents on an impermeable substrate, only with slowly varying fluid flux. We benchmark these theoretical results with laboratory experiments that are consistent with our modelling assumption, but that also highlight the detailed dynamics of drainage inhibited by finite capillary pressure.