scholarly journals Volumetric flow rate in simulations of microfluidic devices

2018 ◽  
Vol 180 ◽  
pp. 02046
Author(s):  
KristÍna Kovalčíková ◽  
Martin Slavík ◽  
Katarína Bachratá ◽  
Hynek Bachratý ◽  
Alžbeta Bohiniková

In this work, we examine the volumetric flow rate of microfluidic devices. The volumetric flow rate is a parameter which is necessary to correctly set up a simulation of a real device and to check the conformity of a simulation and a laboratory experiments [1]. Instead of defining the volumetric rate at the beginning as a simulation parameter, a parameter of external force is set. The proposed hypothesis is that for a fixed set of other parameters (topology, viscosity of the liquid, …) the volumetric flow rate is linearly dependent on external force in typical ranges of fluid velocity used in our simulations. To confirm this linearity hypothesis and to find numerical limits of this approach, we test several values of the external force parameter. The tests are designed for three different topologies of simulation box and for various haematocrits. The topologies of the microfluidic devices are inspired by existing laboratory experiments [3 - 6]. The linear relationship between the external force and the volumetric flow rate is verified in orders of magnitudes similar to the values obtained from laboratory experiments.

2020 ◽  
pp. 0958305X2094531
Author(s):  
Hebert Lugo-Granados ◽  
Lázaro Canizalez-Dávalos ◽  
Martín Picón-Núñez

The aim of this paper is to develop guidelines for the placing of new coolers in cooling systems subject to retrofit. The effects of the accumulation of scale on the flow system are considered. A methodology to assess the interconnected effect of local fluid velocity and fouling deposition is developed. The local average fluid velocity depends on the water flow rate distribution across the piping network. The methodology has four main calculation components: a) the determination of the flow rate distribution across the piping network, b) the prediction of fouling deposition, c) determination of the hydraulic changes and the effect on fouling brought about by the placing of new exchangers into an existing structure, and d) the calculation of the total cooling load and pressure drop of the system. The set of disturbances introduced to the system through fouling and the incorporation of new coolers, create network responses that eventually influence the cooling capacity and the pressure drop. In this work, these interactions are analysed using two case studies. The results indicate that, from the thermal point of view, the incorporation of new heat exchangers is recommended in series. The limit is the point where the increase of the total pressure drop causes a reduction in the overall volumetric flow rate. New coolers added in parallel create a reduction of pressure drop and an increase in the overall water flow rate; however, this increase is not enough to counteract the reduction of fluid velocity and heat capacity removal.


2011 ◽  
Vol 467-469 ◽  
pp. 2013-2017
Author(s):  
Hsiang Chen Hsu ◽  
Hsi Chien Liu ◽  
Cheng Jiun Han

A microfluidic multi-cylindric rapid micromixer is fabricated in the present paper. The key features in the presented MEMS-based microchannel design are (1) micro pump (2) Y-junction type channel (3) cylindric obstacle (4) notch with the edge of sharp teeth. Two different fluids (DI water and red ink) were pumped and injected into Y-type channel, and the fluids were broken-up by a cylindric obstacle in the center of tapered microchannel. The chaotic convection occurs in the mixing channel behind the cylindric obstacle. The mixing index is defined to qualify the mixing efficiency, which demonstrates the outlet notch with sharp teeth along the sidewall plays an important role for mixing effects. The developed micromixer can enhance mixing using the mechanisms of diffusion and convection for wide range of Reynolds number (0.01<Re<100). Parametric studies for volumetric flow rate include the number of cylindric obstacles, the number of notches with sharp-teeth and the width of microchannel. Preliminary results demonstrate that the mixing index reaches the desired effect (<0.1) within 0.08 second when the inlet fluid velocity is 0.49992m/s, i.e. volumetric flow rate is 1200μl /min. The presented device is faster than most of reported micromixers.


2021 ◽  
Author(s):  
Deepak Kumar Maurya ◽  
Satya Deo

Abstract The present work deals with the influence of magnetic field on Newtonian fluid sandwiched between two porous cylindrical pipes which are filled with micropolar fluids. Fluid motion is occurring along z*-axis and applied magnetic field is taken in the direction perpendicular to the direction of fluid motion. On applying appropriate boundary conditions, velocity profiles, microrotations, flow rate and shear stresses are obtained for the corresponding fluid regions. The graphs for volumetric flow rate and fluid velocity are plotted and discussed for different values of micropolar parameter, couple stress parameter, porosity, viscosity ratio parameter, Hartmann number, conductivity ratio parameters and Darcy numbers.MSC (2020): 76A05, 76S05, 76W05, 35Q35


2020 ◽  
Vol 74 (5) ◽  
pp. 305-312
Author(s):  
Miroslav Pavlovic ◽  
Marijana Pantovic-Pavlovic ◽  
Pavel Bartl ◽  
Jasmina Stevanovic ◽  
Bojan Radak

In chemical processes it is essential that the flow in the process is accurately defined. Fluid velocity measurements are important for fluid flow quality performance in flow systems. This study focuses on determination of the volumetric flow rate and its standard (relative) deviation for calibration of conventional flow meters by using a radiotracer approach. The measurements for flow meter calibration were performed at a pilot-scale flow rig using Technetium-99 m (99mTc) as a radiotracer in the form of pertechnetate ion (99mTcO4-). The measured data were analyzed, and precision of the experimental setup was investigated under two different approaches ? IAEA?s RTD software and sum approximation of raw data. For the first time, the variation of standard deviation of calculated flow rate with the injection volume and activity of the radiotracer was determined. Plug flow with axial dispersion was used to simulate the measured RTD curves and investigate the flow dynamics of the flowing water. The results of the study have shown the possibility of in situ calibration of flow meters with a relative error lower than 1 %. They also revealed a slight dependency of the precision of output results on the injection volume as well as similar results for manual and specialized RTD software data processing.


2014 ◽  
pp. 626-635 ◽  
Author(s):  
Florian Emerstorfer ◽  
Christer Bergwall ◽  
Walter Hein ◽  
Mats Bengtsson ◽  
John P. Jensen

The investigations presented in this work were carried out in order to further deepen the knowledge about nitrite pathways in the area of sugar beet extraction. The article consists of two parts with different experimental set-up: the first part focuses on laboratory trials in which the fate of nitrate and nitrite was studied in a so-called mini-fermenter. These trials were carried out using juice from the hot part of the cossette mixer of an Agrana sugar factory in Austria. In the experiments, two common sugar factory disinfectants were used in order to study microbial as well as microbial-chemical effects on nitrite formation and degradation caused by bacteria present in the juice. The trials demonstrated that the direct microbial effect (denitrification) on nitrite degradation is more pronounced than the indirect microbial-chemical effect coming from pH value decrease by these bacteria and subsequent nitrite loss. The second part describes the findings from laboratory experiments and full scale factory trials using a mobile laboratory set-up based on insulated stainless steel containers and spectrophotometric detection of nitrite in various factory juices. The trials were made at two Nordzucker factories located in Finland (factory A) and Sweden (factory B). The inhibiting effect of the two common sugar factory disinfectants on nitrite formation was evaluated in laboratory trials, whereas the full scale trials focused on one disinfectant. Other trials to evaluate potential contamination sources of thermophilic nitrite producing bacteria to the extraction system, reactivation of nitrite producing bacteria in raw juice and the effect of a pH gradient on bacterial nitrite activity in cossette mixer juice are also reported.


2018 ◽  
Vol 11 (1) ◽  
pp. 55-69 ◽  
Author(s):  
Giancarlo Chiatti ◽  
Ornella Chiavola ◽  
Fulvio Palmieri ◽  
Roberto Pompei

Background:The paper deals with a diesel common rail nozzle in which a novel orifice layout is implemented.Objective:Its influence on the nozzle mechanical-hydraulic behavior and on the spray shape transient development is experimentally investigated.Methods:In the research, a solenoid injector for light duty diesel engines is equipped with the novel nozzle prototype and tested. The prototype layout is described, pointing out the features of the nozzle orifices, in which a Slot cross-section is adopted; the investigation is accomplished extending the hydraulic tests and the spray visualizations to a reference nozzle with standard holes. The influence of the hole layout on the mechanical-hydraulic behavior of the nozzle is assessed by experimental analysis based on the rate of injection measurement, in comparison with the reference nozzle. Once the hydraulic behavior of the novel nozzle has been characterized in terms of mass flow rate, the slot influence on the spray shape is assessed analyzing the macroscopic features such as the penetration distance and the spray angle, in non evaporative conditions. The study is carried out under transient injection conditions, for different injection pressures, up to 1400 bar.Results:The results on spray characteristics also provide reference information to set up spray models suited to take the Slot orifice into account.


1987 ◽  
Vol 52 (2) ◽  
pp. 357-371 ◽  
Author(s):  
František Rieger

This paper summarizes the present state of the theory of calculation of the pumping capacity of screw rotors. The calculation starts from the equation for the volumetric flow rate of the flow between two unconfined plates modified by correction coefficients obtained from the relationships for the flow rate in simpler geometrical configurations to which the screw rotor may be, under certain circumstances, reduced.


2021 ◽  
Vol 11 (8) ◽  
pp. 3404
Author(s):  
Majid Hejazian ◽  
Eugeniu Balaur ◽  
Brian Abbey

Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.


1990 ◽  
Vol 52 (8) ◽  
pp. 615-628 ◽  
Author(s):  
Scott K Rowland ◽  
George PL Walker

Sign in / Sign up

Export Citation Format

Share Document