Influence of roughness and capillary size on the zeta potential values obtained by streaming potential measurements

2020 ◽  
Vol 52 (12) ◽  
pp. 991-995 ◽  
Author(s):  
Astrid Drechsler ◽  
Anja Caspari ◽  
Alla Synytska
TAPPI Journal ◽  
2016 ◽  
Vol 15 (5) ◽  
pp. 331-335 ◽  
Author(s):  
LEBO XU ◽  
JEREMY MYERS ◽  
PETER HART

Retention of cationic dispersed rosin size was studied via turbidity measurements on stock filtrate with different alum and dispersed rosin size dosages. Stock charge characteristics were analyzed using both an analysis of charge demand determined via a streaming current detector and an evaluation of zeta potential of the fibers by streaming potential measurement. The results indicated that an optimum amount of alum existed such that good sizing retention was maintained throughout a wide range of dispersed rosin size dosages. However, when an excessive amount of alum was used and fines and colloidal particles were transitioned from anionic to cationic, the cationic size retention was reduced. Laboratory results were confirmed with a paper machine trial. All data suggested that a stock charge study was necessary to identify optimal alum dosage for a cationic dispersed rosin sizing program.


2016 ◽  
Vol 16 (12) ◽  
pp. 2676-2686 ◽  
Author(s):  
Zhong-yi Li ◽  
Ren-kou Xu ◽  
Jiu-yu Li ◽  
Zhi-neng Hong

2012 ◽  
Vol 516-517 ◽  
pp. 1870-1873 ◽  
Author(s):  
Jun Wang ◽  
Heng Shan Hu

The electrokinetic effects are important in the understanding of electric properties in porous medium. In this study, the streaming potential and streaming current of saturated samples are measured at different concentrations, then three methods are applied to obtain the zeta-potential and electrokinetic coupling coefficient. The study shows that the results obtained from streaming potential and streaming current methods agree well with each other, but the results obtained from simplified streaming potential method become seriously inaccurate at low concentrations due to the influence of surface conductance. This experimental study also provides a reliable estimate of the surface conductivity and its contribution to zeta-potential at given concentrations.


2011 ◽  
Vol 360 (1) ◽  
pp. 195-203 ◽  
Author(s):  
Maria Zaucha ◽  
Zbigniew Adamczyk ◽  
Jakub Barbasz

1963 ◽  
Vol 18 (6) ◽  
pp. 1263-1264 ◽  
Author(s):  
R. E. Beck ◽  
V. Mirkovitch ◽  
P. G. Andrus ◽  
R. I. Leininger

A system was developed to measure the streaming potential generated between the ends of a capillary by the flow of a fluid through the capillary. Zeta potential can be calculated from the streaming potential. Adequate sensitivity and reproducibility were achieved by making special electrodes: silver wires plated in KCl solution and embedded in agar, careful electrical shielding, and provision for reversal of flow through the capillary to minimize electrode errors. The apparatus was developed to measure streaming potentials generated by either RingerS's solution or blood in contact with capillaries made of different materials such as quartz, polyethylene, etc. An example of a determination using a quartz capillary is presented. interfaces; blood; salt solutions; glass; quartz Submitted on February 25, 1963


2010 ◽  
Vol 81 (1) ◽  
pp. 015106 ◽  
Author(s):  
N. Guzelsu ◽  
C. Wienstien ◽  
S. P. Kotha

Author(s):  
Paul Glover ◽  
Rong Peng ◽  
Piroska Lorinczi ◽  
Bangrang Di

<p>The development of seismo-electric (SE) exploration techniques relies significantly upon being able to understand and quantify the strength of frequency-dependent SE conversion. However, there have been very few SE measurements or modelling carried out. In this paper we present two experimental methods for making such measurements, and examine how the strength of SE conversion depends on frequency, porosity, permeability, and why it is unusual in shales. The first is based on an electromagnetic shaker and can be used in the 1 Hz to 2 kHz frequency range. The second is a piezo-electric water-bath apparatus which can be used in the 1kHz to 500 kHz frequency range.</p><p>The first apparatus has been tested on samples of Berea sandstone. Both the in-phase and in-quadrature components of the streaming potential coefficient have been measured with an uncertainty of better than ±4%. The experimental measurements show the critical frequency at which the quadrature component is maximal, and the frequency of this component is shown to agree very well with both permeability and grain size. The experimental measurements have been modelled using several different methods.</p><p>The second apparatus was used to measure SE coupling as a function of porosity and permeability, interpreting the results using a micro-capillary model and current theory. We found a general agreement between the theoretical curves and the test data, indicating that SE conversion is enhanced by increases in porosity over a range of different frequencies. However, SE conversion has a complex relationship with rock permeability, which changes with frequency, and which is more sensitive to changes in the petrophysical properties of low-permeability samples. This observation suggests that seismic conversion may have advantages in characterizing low permeability reservoirs such as tight gas and tight oil reservoirs as well as shale gas reservoirs.</p><p>We have also carried out SE measurements on Sichuan Basin shales (permeability 1.47 – 107 nD), together with some comparative measurements on sandstones (0.2 – 60 mD). Experimental results show that SE conversion in shales is comparable to that exhibited by sandstones, and is approximately independent of frequency in the seismic frequency range (<1 kHz). Anisotropy which arises from bedding in the shales results in anisotropy in the streaming potential coefficient. Numerical modelling has been used to examine the effects of varying zeta potential, porosity, tortuosity, dimensionless number and permeability. It was found that SE conversion is highly sensitive to changes in porosity, tortuosity and zeta potential in shales. Numerical modelling suggests that the cause of the SE conversion in shales is enhanced zeta potentials caused by clay minerals, which are highly frequency dependent. This is supported by a comparison of our experimental data with numerical modelling as a function of clay mineral composition from XRD measurements. Consequently, the sensitivity of SE coupling to the clay minerals suggests that SE exploration may have potential for the characterization of clay minerals in shale gas and shale oil reservoirs.</p>


2011 ◽  
Vol 63 (6) ◽  
pp. 1303-1308
Author(s):  
Daan Curvers ◽  
Hans Saveyn ◽  
Wim Van den Broeck ◽  
Patrick Van Oostveldt ◽  
Paul Van der Meeren

Charge neutralisation is an important mechanism in (polyelectrolyte) conditioning of biotic sludges and required for efficient sludge dewatering. Based on results from streaming potential and zeta potential measurements, it has been suggested that charge neutralisation is more complete on the outside of the sludge flocs than on the inside. This paper discusses the development of a technique for assessing the spatial distribution of polyelectrolyte (PE) within sludge flocs. After flocculation with a fluorescently labelled PE, fluorescence microscopy can be used to visualise the distribution of the PE in the sludge flocs. Preliminary results indicate that the PE can penetrate relatively deep into the sludge flocs (and flocculi). Inhomogeneity in the PE distribution arises from differences in exposure to PE in different regions, and from differences in the affinity of the PE for different substances.


2006 ◽  
Vol 314 ◽  
pp. 19-24 ◽  
Author(s):  
Cornelia Bellmann ◽  
Anja Caspari

The process of electrophoretic deposition depends strongly on the electrokinetic properties and with it the surface properties of the material that will be processed. Different additives, conditioners but also the suspending liquid influence the surface of the applied material by adsorption. Electrokinetic investigations reflect changes in properties at the outermost solid surface very sensitive. Streaming potential measurements are especially suited for studying such changes of surface chemistry at solids with different shapes. Two approaches are applicable: 1. The adsorption process was done before measuring. The result of this process should be shown. In this case it will be interesting to see differences in the functionality of the solid surface. The zeta potential will be measured versus different pH value. 2. The adsorption process will be studied directly. The zeta potential will be determined versus the concentration of the adsorptive. The second approach can be used for investigation of adsorption of multicomponent mixtures. Competing adsorption processes are detectable.


Sign in / Sign up

Export Citation Format

Share Document