Energy Efficient Stone Cellular Concrete Masonry on Polyurethane Adhesive

Author(s):  
L. A. Suleymanova ◽  
I. A. Pogorelova ◽  
I. S. Ryabchevskiy
2019 ◽  
Vol 8 (4) ◽  
pp. 7692-7694

This article presents theoretical studies on the mathematical modeling of the structure of constructive thermal insulation building materials. The developed principle block is a diagram of the methodology of structural and simulation modeling of cellular concrete.


Author(s):  
L A Suleymanova ◽  
I A Pogorelova ◽  
M V Marushko ◽  
I S Ryabchevsky

Author(s):  
Said S. Shaumarov

Based on the performed theoretical studies and calculations, the developed methodological foundations of designing the external enclosing structures of energy-efficient buildings based on cellular concrete with a given set of properties are presented, which are of great economic importance for construction oriented in the modern period towards the creation of energy-efficient civil facilities


2019 ◽  
Vol 97 ◽  
pp. 02009
Author(s):  
Said Shaumarov ◽  
Anvar Adilkhodjaev ◽  
Valeriy Kondrazhenko

The article presents the results of research to determine the porosity of cellular concrete with different volume mass and strength by the method of “image analysis”. A photo-optical method of cellular concrete structure estimation is developed. The dependence of porosity and strength of the samples on the fractal dimension of the cellular concrete structure is obtained.


2014 ◽  
Vol 941-944 ◽  
pp. 786-799 ◽  
Author(s):  
G. I. Grinfeld ◽  
Alexsandr S. Gorshkov ◽  
Nikolay I. Vatin

This article deals with the strength and thermophysical test results made on the basis of the masonry samples of cellular autoclave curing concrete (aerated concrete blocks) with the use of polyurethane adhesive. Aerated concrete masonry walling with the use of polyurethane adhesive is indicated herein to be technologically feasible and economically viable. The major advantage of the masonry option under consideration lies in the following aspect: thermal conductivity of polyurethane adhesive used to fasten aerated concrete blocks in masonry walls is significantly less than thermal conductivity of concrete adhesives and mortars. For this reason, thermal insulation properties of the masonry with polyurethane adhesive appear to be better comparatively to the block masonry made with the usage of concrete adhesives of any other type. On the ground of the tests conducted the following was resumed: it is acceptable to carry out masonry works with the use of aerated concrete blocks and polyurethane adhesive in construction of exterior and interior nonbearing walls provided appropriate justifying calculations are made.


2011 ◽  
Author(s):  
B. Smitha Shekar ◽  
M. Sudhakar Pillai ◽  
G. Narendra Kumar

2020 ◽  
Vol 39 (6) ◽  
pp. 8139-8147
Author(s):  
Ranganathan Arun ◽  
Rangaswamy Balamurugan

In Wireless Sensor Networks (WSN) the energy of Sensor nodes is not certainly sufficient. In order to optimize the endurance of WSN, it is essential to minimize the utilization of energy. Head of group or Cluster Head (CH) is an eminent method to develop the endurance of WSN that aggregates the WSN with higher energy. CH for intra-cluster and inter-cluster communication becomes dependent. For complete, in WSN, the Energy level of CH extends its life of cluster. While evolving cluster algorithms, the complicated job is to identify the energy utilization amount of heterogeneous WSNs. Based on Chaotic Firefly Algorithm CH (CFACH) selection, the formulated work is named “Novel Distributed Entropy Energy-Efficient Clustering Algorithm”, in short, DEEEC for HWSNs. The formulated DEEEC Algorithm, which is a CH, has two main stages. In the first stage, the identification of temporary CHs along with its entropy value is found using the correlative measure of residual and original energy. Along with this, in the clustering algorithm, the rotating epoch and its entropy value must be predicted automatically by its sensor nodes. In the second stage, if any member in the cluster having larger residual energy, shall modify the temporary CHs in the direction of the deciding set. The target of the nodes with large energy has the probability to be CHs which is determined by the above two stages meant for CH selection. The MATLAB is required to simulate the DEEEC Algorithm. The simulated results of the formulated DEEEC Algorithm produce good results with respect to the energy and increased lifetime when it is correlated with the current traditional clustering protocols being used in the Heterogeneous WSNs.


Author(s):  
Yugashree Bhadane ◽  
Pooja Kadam

Now days, wireless technology is one of the center of attention for users and researchers. Wireless network is a network having large number of sensor nodes and hence called as “Wireless Sensor Network (WSN)”. WSN monitors and senses the environment of targeted area. The sensor nodes in WSN transmit data to the base station depending on the application. These sensor nodes communicate with each other and routing is selected on the basis of routing protocols which are application specific. Based on network structure, routing protocols in WSN can be divided into two categories: flat routing, hierarchical or cluster based routing, location based routing. Out of these, hierarchical or cluster based routing is becoming an active branch of routing technology in WSN. To allow base station to receive unaltered or original data, routing protocol should be energy-efficient and secure. To fulfill this, Hierarchical or Cluster base routing protocol for WSN is the most energy-efficient among other routing protocols. Hence, in this paper, we present a survey on different hierarchical clustered routing techniques for WSN. We also present the key management schemes to provide security in WSN. Further we study and compare secure hierarchical routing protocols based on various criteria.


Author(s):  
Ye.Ye. Nikitin

The current situation in the sphere of district heating is analysed on the basis of use of the cognitive approach. The presence of closed chains of cause-effect relationships of negative factors and conflicts of target settings of the subjects in the field of district heating is shown. The conceptual model of energy efficient modernization of district heating systems is proposed. This model includes indicators of the current status of heat sources, networks and heat consumers, energetic and economic models, restrictions, procedure of forming and analysis of the mutual influence of the recommended projects. The quantitative data on indicators of the current state of district heating systems of the cities of Ukraine are presented. The interrelation between indicators of the current state and projects of energy efficient modernization of district heating systems is shown. Assessment of energy self-sufficiency of municipal district heating systems on condition of thermal modernization of buildings is carried out. The creation of energy management systems at the district heating enterprises is proposed. Bib. 6, Fig. 7, Tab. 5.


Sign in / Sign up

Export Citation Format

Share Document