Detection of Signals by the Frequency-Time Contrast Method

Author(s):  
Konstantin Rumyantsev ◽  
Aatoliy Zikiy ◽  
Pavel Zlaman
Author(s):  
N.S. Allen ◽  
R.D. Allen

Various methods of video-enhanced microscopy combine TV cameras with light microscopes creating images with improved resolution, contrast and visibility of fine detail, which can be recorded rapidly and relatively inexpensively. The AVEC (Allen Video-enhanced Contrast) method avoids polarizing rectifiers, since the microscope is operated at retardations of λ/9- λ/4, where no anomaly is seen in the Airy diffraction pattern. The iris diaphram is opened fully to match the numerical aperture of the condenser to that of the objective. Under these conditions, no image can be realized either by eye or photographically. Yet the image becomes visible using the Hamamatsu C-1000-01 binary camera, if the camera control unit is equipped with variable gain control and an offset knob (which sets a clamp voltage of a D.C. restoration circuit). The theoretical basis for these improvements has been described.


Author(s):  
G.D. Danilatos

The possibility of placing the specimen in a gaseous medium in the environmental SEM (ESEM) has created novel ways for detection of signals from the beam-specimen interactions. It was originally reported by Oanilatos that the ionization produced by certain signals inside the conditioning medium can be used to produce images. The aim of this report is to demonstrate some of the improvements on the system that have occurred thereafter.Two straight thin wires are aligned horizontally along a direction normal to the direction of the two scintillator backscattered electron (BSE) detectors reported elsewhere. The free end tips of the wires are about 5 mm apart halfway between the specimen and the pressure limiting aperture (specimen distance = 1.5 mm). The other end of each wire makes contact with the input of a separate preamplifier, two of which are built inside a shielding aluminum stub. With such a design, interference noise from the input cables is avoided.


2018 ◽  
Vol 1 (1) ◽  
pp. 48-61
Author(s):  
D. A. Balakin ◽  
◽  
S. S. Churkin ◽  
V. V. Shtykov ◽  
◽  
...  

Author(s):  
V.F. Kravchenko ◽  
◽  
O.V. Kravchenko ◽  
V.I. Lutsenko ◽  
I.V. Lutsenko ◽  
...  

Author(s):  
Jan Euteneuer ◽  
Cornelius Courts

AbstractMolecular ballistics combines molecular biological, forensic ballistic, and wound ballistic insights and approaches in the description, collection, objective investigation, and contextualization of the complex patterns of biological evidence that are generated by gunshots at biological targets. Setting out in 2010 with two seminal publications proving the principle that DNA from backspatter collected from inside surfaces of firearms can be retreived and successfully be analyzed, molecular ballistics covered a lot of ground until today. In this review, 10 years later, we begin with a comprehensive description and brief history of the field and lay out its intersections with other forensic disciplines like wound ballistics, forensic molecular biology, blood pattern analysis, and crime scene investigation. In an application guide section, we aim to raise consciousness to backspatter traces and the inside surfaces of firearms as sources of forensic evidence. Covering crime scene practical as well as forensic genetic aspects, we introduce operational requirements and lay out possible procedures, including forensic RNA analysis, when searching for, collecting, analyzing, and contextualizing such trace material. We discuss the intricacies and rationales of ballistic model building, employing different tissue, skin, and bone simulants and the advantages of the “triple-contrast” method in molecular ballistics and give advice on how to stage experimental shootings in molecular ballistic research. Finally, we take a look at future applications and prospects of molecular ballistics.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Xiaoqing Zhong ◽  
Feihu Xu ◽  
Hoi-Kwong Lo ◽  
Li Qian

AbstractQuantum communication complexity explores the minimum amount of communication required to achieve certain tasks using quantum states. One representative example is quantum fingerprinting, in which the minimum amount of communication could be exponentially smaller than the classical fingerprinting. Here, we propose a quantum fingerprinting protocol where coherent states and channel multiplexing are used, with simultaneous detection of signals carried by multiple channels. Compared with an existing coherent quantum fingerprinting protocol, our protocol could consistently reduce communication time and the amount of communication by orders of magnitude by increasing the number of channels. Our proposed protocol can even beat the classical limit without using superconducting-nanowire single photon detectors. We also report a proof-of-concept experimental demonstration with six wavelength channels to validate the advantage of our protocol in the amount of communication. The experimental results clearly prove that our protocol not only surpasses the best-known classical protocol, but also remarkably outperforms the existing coherent quantum fingerprinting protocol.


2010 ◽  
Vol 90 (2) ◽  
pp. 719-726 ◽  
Author(s):  
L. Vergara ◽  
J. Moragues ◽  
J. Gosálbez ◽  
A. Salazar

Sign in / Sign up

Export Citation Format

Share Document