Indirect measurement of the rock weight in the bucket of a loading-transporting machine

1993 ◽  
Vol 28 (4) ◽  
pp. 361-364
Author(s):  
�. G. Chaikovskii ◽  
E. V. Rubtsova
TAPPI Journal ◽  
2018 ◽  
Vol 17 (05) ◽  
pp. 261-269
Author(s):  
Wei Ren ◽  
Brennan Dubord ◽  
Jason Johnson ◽  
Bruce Allison

Tight control of raw green liquor total titratable alkali (TTA) may be considered an important first step towards improving the overall economic performance of the causticizing process. Dissolving tank control is made difficult by the fact that the unknown smelt flow is highly variable and subject to runoff. High TTA variability negatively impacts operational costs through increased scaling in the dissolver and transfer lines, increased deadload in the liquor cycle, under- and over-liming, increased energy consumption, and increased maintenance. Current practice is to use feedback control to regulate the TTA to a target value through manipulation of weak wash flow while simultaneously keeping dissolver density within acceptable limits. Unfortunately, the amount of variability reduction that can be achieved by feedback control alone is fundamentally limited by the process dynamics. One way to improve upon the situation would be to measure the smelt flow and use it as a feedforward control variable. Direct measurement of smelt flow is not yet possible. The use of an indirect measurement, the dissolver vent stack temperature, is investigated in this paper as a surrogate feedforward variable for dissolving tank TTA control. Mill trials indicate that significant variability reduction in the raw green liquor TTA is possible and that the control improvements carry through to the downstream processes.


2016 ◽  
Author(s):  
Lucilene F. Mouzinho ◽  
João Viana da Fonseca Neto ◽  
Benedito A. Luciano ◽  
Raimundo Carlos S. Freire

1979 ◽  
Vol 44 (2) ◽  
pp. 295-306 ◽  
Author(s):  
Ivan Cibulka ◽  
Vladimír Hynek ◽  
Robert Holub ◽  
Jiří Pick

A digital vibrating-tube densimeter was constructed for measuring the density of liquids at several temperatures. The underlying principle of the apparatus is the measurement of the period of eigen-vibrations of a V-shaped tube; the second power of the period of the vibrations is proportional to the density of the liquid in the tube. The temperature of the measuring system is controlled by an electronic regulator. The mean error in the density measurement is approximately ±1 . 10-5 g cm-3 at 25 °C and ±2 . 10-5 g cm-3 at 40 °C. The apparatus was used for an indirect measurement of the excess volume, tested with the benzene-cyclohexane system and further used for determining the excess volume of the benzene-methanol, benzene-acetonitrile and methanol-acetonitrile systems at 25 and 40 °C.


2021 ◽  
Vol 9 (2) ◽  
pp. 118
Author(s):  
Xinqing Zhuang ◽  
Keliang Yan ◽  
Pan Gao ◽  
Yihua Liu

Anchor dragging is a major threat to the structural integrity of submarine pipelines. A mathematical model in which the mechanical model of chain and the bearing model of anchor were coupled together. Based on the associated flow rule, an incremental procedure was proposed to solve the spatial state of anchor until it reaches the ultimate embedding depth. With an indirect measurement method for the anchor trajectory, a model test system was established. The mathematical model was validated against some model tests, and the effects of two parameters were studied. It was found that both the ultimate embedding depth of a dragging anchor and the distance it takes to reach the ultimate depth increase with the shank-fluke pivot angle, but decrease as the undrained shear strength of clay increases. The proposed model is supposed to be useful for the embedding depth calculation and guiding the design of the pipeline burial depth.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 593
Author(s):  
Ryota Yanagisawa ◽  
Shunsuke Shigaki ◽  
Kotaro Yasui ◽  
Dai Owaki ◽  
Yasuhiro Sugimoto ◽  
...  

In this study, we fabricated a novel wearable vibration sensor for insects and measured their wing flapping. An analysis of insect wing deformation in relation to changes in the environment plays an important role in understanding the underlying mechanism enabling insects to dynamically interact with their surrounding environment. It is common to use a high-speed camera to measure the wing flapping; however, it is difficult to analyze the feedback mechanism caused by the environmental changes caused by the flapping because this method applies an indirect measurement. Therefore, we propose the fabrication of a novel film sensor that is capable of measuring the changes in the wingbeat frequency of an insect. This novel sensor is composed of flat silver particles admixed with a silicone polymer, which changes the value of the resistor when a bending deformation occurs. As a result of attaching this sensor to the wings of a moth and a dragonfly and measuring the flapping of the wings, we were able to measure the frequency of the flapping with high accuracy. In addition, as a result of simultaneously measuring the relationship between the behavior of a moth during its search for an odor source and its wing flapping, it became clear that the frequency of the flapping changed depending on the frequency of the odor reception. From this result, a wearable film sensor for an insect that can measure the displacement of the body during a particular behavior was fabricated.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 75
Author(s):  
Thommas Kevin Sales Flores ◽  
Juan Moises Mauricio Villanueva ◽  
Heber P. Gomes ◽  
Sebastian Y. C. Catunda

Indirect measurement can be used as an alternative to obtain a desired quantity, whose physical positioning or use of a direct sensor in the plant is expensive or not possible. This procedure can been improved by means of feedback control strategies of a secondary variable, which can be measured and controlled. Its main advantage is a new form of dynamic response, with improvements in the response time of the measurement of the quantity of interest. In water pumping networks, this methodology can be employed for measuring the flow indirectly, which can be advantageous due to the high price of flow sensors and the operational complexity to install them in pipelines. In this work, we present the use of artificial intelligence techniques in the implementation of the feedback system for indirect flow measurement. Among the contributions of this new technique is the design of the pressure controller using the Fuzzy logic theory, which rules out the need for knowing the plant model, as well as the use of an artificial neural network for the construction of nonlinear models with the purpose of indirectly estimating the flow. The validation of the proposed approach was carried out through experimental tests in a water pumping system, fully automated and installed at the Laboratory of Hydraulic and Energy Efficiency in Sanitation at the Federal University of Paraiba (LENHS/UFPB). The results were compared with an electromagnetic flow sensor present in the system, obtaining a maximum relative error of 10%.


Life ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 341
Author(s):  
Małgorzata Kałużna ◽  
Krzysztof Pawlaczyk ◽  
Krzysztof Schwermer ◽  
Krzysztof Hoppe ◽  
Aisha Yusuf Ibrahim ◽  
...  

Background: Preptin is a bone-anabolic pancreatic peptide hormone. Its role in bone metabolism has been studied in rats and in patients with diabetes, but its levels and significance in bone metabolism in hemodialyzed (HD) patients is unknown. Methods: The relationships between preptin and anthropometric and biochemical parameters related to bone metabolism were studied in 73 patients on chronic hemodialysis (48 males, 25 females; mean age of 57 years; HD vintage of 69.7 months). Of these subjects, 36 patients had diabetes or impaired glucose tolerance (DM/IGT), and 37 patients had normal glucose tolerance (NGT). Dual-energy X-ray absorptiometry of the femoral neck and lumbar spine were also performed. Results: No differences were observed in preptin levels between DM/IGT and NGT HD patients. Preptin was positively correlated with HD vintage (r = 0.312, p = 0.007). Negative correlations between preptin and bone mineral density (BMD), T-score, and Z-score in the lumbar spine (L2-L4) were observed (r = −0.319, p = 0.009; r = −0.341, p = 0.005; r = −0.375, p = 0.002). Preptin was positively correlated with parathormone (PTH) levels (r = 0.379, p < 0.001) and osteocalcin levels (r = 0.262, p = 0.027). Conclusions: The results indicate that preptin may reflect on bone and mineral metabolism disturbances seen in HD patients. The significant correlation of preptin with PTH and osteocalcin suggests that preptin may be important in indirect measurement of bone turnover in HD patients.


Sign in / Sign up

Export Citation Format

Share Document