Heat and mass transfer characteristics of organic sorbent coated on heat transfer surface of a heat exchanger

2008 ◽  
Vol 44 (11) ◽  
pp. 1305-1313 ◽  
Author(s):  
Hideo Inaba ◽  
Fujio Komatsu ◽  
Akihiko Horibe ◽  
Naoto Haruki ◽  
Akito Machida
2006 ◽  
Vol 129 (9) ◽  
pp. 1256-1267 ◽  
Author(s):  
Worachest Pirompugd ◽  
Chi-Chuan Wang ◽  
Somchai Wongwises

This study proposes a new method, namely the “fully wet and fully dry tiny circular fin method,” for analyzing the heat and mass transfer characteristics of plain fin-and-tube heat exchangers under dehumidifying conditions. The present method is developed from the tube-by-tube method proposed in the previous study by the same authors. The analysis of the fin-and-tube heat exchangers is carried out by dividing the heat exchanger into many tiny segments. A tiny segment will be assumed with fully wet or fully dry conditions. This method is capable of handling the plain fin-and-tube heat exchanger under fully wet and partially wet conditions. The heat and mass transfer characteristics are presented in dimensionless terms. The ratio of the heat transfer characteristic to mass transfer characteristic is also studied. Based on the reduced results, it is found that the heat transfer and mass transfer characteristics are insensitive to changes in fin spacing. The influence of the inlet relative humidity on the heat transfer characteristic is rather small. For one and two row configurations, a considerable increase of the mass transfer characteristic is encountered when partially wet conditions take place. The heat transfer characteristic is about the same in fully wet and partially wet conditions provided that the number of tube rows is equal to or greater than four. Correlations are proposed to describe the heat and mass characteristics for the present plain fin configuration.


Author(s):  
Yao Li ◽  
Haiqing Si ◽  
Jingxuan Qiu ◽  
Yingying Shen ◽  
Peihong Zhang ◽  
...  

Abstract The plate-fin heat exchanger has been widely applied in the field of air separation and aerospace due to its high specific surface area of heat transfer. However, the low heat transfer efficiency of its plate bundles has also attracted more attention. It is of great significance to optimize the structure of plate-fin heat exchanger to improve its heat transfer efficiency. The plate bundle was studied by combining numerical simulation with experiment. Firstly, according to the heat and mass transfer theory, the plate bundle calculation model of plate-fin heat exchanger was established, and the accuracy of the UDF (User-Defined Functions) for describing the mass and heat transfer was verified. Then, the influences of fin structure parameters on the heat and mass transfer characteristics of channel were discussed, including the height, spacing, thickness and length of fins. Finally the influence of various factors on the flow field performance under different flow states was integrated to complete the optimal design of the plate bundle.


2014 ◽  
Vol 136 (12) ◽  
Author(s):  
Raj Nandkeolyar ◽  
Peri K. Kameswaran ◽  
Sachin Shaw ◽  
Precious Sibanda

We investigated heat and mass transfer on water based nanofluid due to the combined effects of homogeneous–heterogeneous reactions, an external magnetic field and internal heat generation. The flow is generated by the movement of a linearly stretched surface, and the nanofluid contains nanoparticles of copper and gold. Exact solutions of the transformed model equations were obtained in terms of hypergeometric functions. To gain more insights regarding subtle impact of fluid and material parameters on the heat and mass transfer characteristics, and the fluid properties, the equations were further solved numerically using the matlab bvp4c solver. The similarities and differences in the behavior, including the heat and mass transfer characteristics, of the copper–water and gold–water nanofluids with respect to changes in the flow parameters were investigated. Finally, we obtained the numerical values of the skin friction and heat transfer coefficients.


2001 ◽  
Author(s):  
Y. H. Kim ◽  
Y. J. Park ◽  
Y. C. Kim ◽  
S. C. Shim ◽  
S. K. Oh ◽  
...  

Abstract An experimental study was performed to investigate the heat and mass transfer characteristics of a finned-tube evaporator coil utilized in a domestic refrigerator under frosting conditions. Airside heat transfer coefficient was measured as a function of air temperature, humidity ratio, air velocity, and evaporating temperature. In addition, frost thickness was monitored and measured by visualization tests during frosting operation. Based on the experimental results, the degradation of heat transfer performance due to frost formation was explored as a function of operating parameters. The rate of frost formation on the evaporator increases at relatively high humidity, high airflow rate, low inlet air temperature and low refrigerant temperature. As the frost thickness increases, airflow rate gradually decreases, while the capacity increases at the early stage of frost formation and then significantly drops.


Author(s):  
R. Z. Wang ◽  
Z. Z. Xia ◽  
L. W. Wang ◽  
Z. S. Lu ◽  
S. L. Li ◽  
...  

Adsorption refrigeration and heat pump systems have been considered as very important means for the efficient use of low grade thermal energy in the temperature range of 60–150°C. Sorption systems are merely heat exchanger based thermodynamic systems, and therefore a good design to optimize heat and mass transfer with reaction or sorption processes is very important for high performance of the systems. Studies on heat and mass transfer enhancement in adsorption beds have been done extensively. Notable techniques is whereby the adsorbent bed is fitted with finned heat exchanger embedded with adsorbent particles, or the adsorbent particles may be compressed and solidified and then coupled with finned tube or plate heat exchangers. The use of expanded graphite seems to be an effective method to improve both heat and mass transfer in the reaction bed. Studies have also shows the need to enhance the heat transfer in adsorption bed to match with the heat transfer of thermal fluids. Use of heat pipes and good thermal loop design could yield higher thermal performances of a sorption system, when coupled with adsorption beds to provide heating and cooling to the beds. A novel design with passive evaporation, known as rising film evaporation coupled with a gravity heat pipe was introduced for high cooling output. It has also been shown that heat and mass recovery in the internal sorption systems is critical, and novel arrangement of thermal fluid and refrigerant may result in high performance sorption systems. Based upon the above researches, various sorption systems have been developed, and high efficient performances have been reached. Typical sorption systems include (1) A silica gel-water adsorption water chillier with a COP about 0.55 when powered with 80°C hot water, (2) A CaCl2-ammonia adsorption refrigerator with a COP over 0.3 at −20 °C when powered with 120 °C water vapor, which has a specific cooling power about 600 W/kg-adsorbent. The above mentioned systems have shown that solid sorption systems have become market potential products, and low grade thermal energy, which is usually considered as waste heat, could be utilized to provide high grade cooling. This paper gives details of high efficient solid sorption systems recently developed, their heat transfer design, thermodynamic system coupling, and performance test results. Some examples of low grade thermal powered cooling systems are also presented.


Author(s):  
S. E. Tarasevich ◽  
A. B. Yakovlev ◽  
A. A. Giniyatullin ◽  
A. V. Shishkin

Results of an experimental research of structure of an adiabatic two-phase (air-to-water) flow in tubes with the twisted tape insert are presented. The basic feature of structure in such channels is that a liquid phase part (and all liquid at the high range of gas qualities) moves in the form of a stream (a cord) on the tape and doesn’t contact to an active heat transfer surface. The device for an intensification of a heat and mass transfer (especially at boiling) in the form of the twisted tape with ribs discretely installed on an angle to a tape axis is offered. Ribs on a tape promote displacement of a liquid from a tape to a tube heat transfer surface. Results of an experimental research of a heat transfer and a hydraulic resistance in tubes with various tape twisting inserts also are presented. Possibility of an effective utilization of the twisted tapes with ribs for an intensification of a heat and mass transfer in tubes is shown.


1998 ◽  
Vol 120 (4) ◽  
pp. 299-304 ◽  
Author(s):  
L. Rosario ◽  
M. M. Rahman

The aim of this paper is the analysis of heat transfer in a radial fin assembly during the process of dehumidification. An individual finned tube geometry is a reasonable representation of heat exchangers used in air conditioning. The condensation process involves both heat and mass transfer and the cooling takes place by the removal of sensible as well as latent heat. The ratio of sensible to total heat is an important quantity that defines the heat transfer process during a dehumidifier operation. A one-dimensional model for heat transfer in the fin and the heat exchanger block is developed to study the effects of condensation on the fin surface. The combined heat and mass transfer process is modeled by incorporating the ratio of sensible to total heat in the formulation. The augmentation of heat transfer due to fin was established by comparing the heat transfer rate with and without fins under the same operating conditions. Calculations were carried out to study the effects of relative humidity and dry bulb temperature of the incoming air, and cold fluid temperature inside the coil on the performance of the heat exchanger. An analysis of the overall efficiency for the assembly was also done. Results were compared to those under dry conditions, wherever appropriate. Comparison between present results and those published for rectangular as well as radial fins under fully wet conditions were made. These comparisons established the validity of the present model. It was found that the heat transfer rate increased with increment in both dry bulb temperature and relative humidity of the air. The augmentation factor, however, decreased with increment in relative humidity and the dry bulb temperature. The fin efficiency decreased with relative humidity.


Sign in / Sign up

Export Citation Format

Share Document