Sodium dodecylbenzenesulfonate–based silver nanoparticles and their potent application as antibiofilm, antimicrobial agent, and trace level determination of amlodipine

Plasmonics ◽  
2020 ◽  
Author(s):  
Sobia Hashim ◽  
Syed Abid Ali ◽  
Asma Siddiqui ◽  
Syed Waseem Ahmed ◽  
Syeda Sumra Naqvi ◽  
...  
RSC Advances ◽  
2021 ◽  
Vol 11 (20) ◽  
pp. 12227-12234
Author(s):  
Hisham S. M. Abd-Rabboh ◽  
Abd El-Galil E. Amr ◽  
Elsayed A. Elsayed ◽  
Ahmed Y. A. Sayed ◽  
Ayman H. Kamel

Robust, reliable and cost-effective paper-based analytical device for potentiometric pholcodine (opiate derivative drug) ion sensing has been prepared and characterized.


Talanta ◽  
2011 ◽  
Vol 85 (3) ◽  
pp. 1658-1664 ◽  
Author(s):  
Subarna Guha ◽  
Sisir Lohar ◽  
Ipsit Hauli ◽  
Subhra K. Mukhopadhyay ◽  
Debasis Das

2016 ◽  
Vol 8 (42) ◽  
pp. 7702-7710 ◽  
Author(s):  
C. Moscoso-Pérez ◽  
V. Fernández-González ◽  
J. Moreda-Piñeiro ◽  
P. López-Mahía ◽  
S. Muniategui-Lorenzo ◽  
...  

A simple, rapid and inexpensive method using PTV-GC-MS was developed for the simultaneous trace level determination of organometallic compounds of mercury, lead and tin.


RSC Advances ◽  
2015 ◽  
Vol 5 (21) ◽  
pp. 16284-16291 ◽  
Author(s):  
Chelladurai Karuppiah ◽  
Selvakumar Palanisamy ◽  
Shen-Ming Chen ◽  
R. Emmanuel ◽  
K. Muthupandi ◽  
...  

The green synthesis of metal nanoparticles is found to be more attractive in various disciplines, including in analytical chemistry for heavy metal ion sensing.


Author(s):  
LAKSHMI NARASIMHA RAO KATAKAM ◽  
THIRUPATHI DONGALA

Objective: A novel study on a new liquid chromatographic approach has been developed and validated for simultaneous determination of trace level determination of sodium chloride and sodium sulfate measures its impurities using counter cation-exchange high-performance liquid chromatography with indirect ultraviolet (UV) detection. Methods: Chromatographic separation is developed and validated on a Hamilton PRP-X100 column with a mobile phase contained a mixture of the para-hydroxybenzoic acid buffer with a pH of 9.0 and methanol. Chromatography is developed at a flow rate of 2.0 mL/min with an indirect UV determination at 310 nm at a sensitivity level of 0.5%. The optimized method was validated as per the ICH Q2 guidelines. Results: The retention times of chloride and sulfate were about 2.8 and 7.6 min, respectively. The resolution between chloride and sulfate peaks is >4. Regression analysis confers a correlation coefficient for the stated compounds that are found to be >0.999. Conclusion: A novel analytical method was validated as per the ICH method validation guidelines and found to be selective. Hence, the validated analytical method was precise, specific, and accurate, and it is more economic and simple for the determination of inorganic impurities.


Sign in / Sign up

Export Citation Format

Share Document