scholarly journals Sensitivity, Specificity and Accuracy of a Novel EEG-Based Objective Test, the Cognalyzer®, in Detecting Cannabis Psychoactive Effects

Author(s):  
Alison C. McDonald ◽  
Israel Gasperin Haaz ◽  
Weikai Qi ◽  
David C. Crowley ◽  
Najla Guthrie ◽  
...  
Author(s):  
Ling-Yu Guo ◽  
Phyllis Schneider ◽  
William Harrison

Purpose This study provided reference data and examined psychometric properties for clausal density (CD; i.e., number of clauses per utterance) in children between ages 4 and 9 years from the database of the Edmonton Narrative Norms Instrument (ENNI). Method Participants in the ENNI database included 300 children with typical language (TL) and 77 children with language impairment (LI) between the ages of 4;0 (years;months) and 9;11. Narrative samples were collected using a story generation task, in which children were asked to tell stories based on six picture sequences. CD was computed from the narrative samples. The split-half reliability, concurrent criterion validity, and diagnostic accuracy were evaluated for CD by age. Results CD scores increased significantly between ages 4 and 9 years in children with TL and those with LI. Children with TL produced higher CD scores than those with LI at each age level. In addition, the correlation coefficients for the split-half reliability and concurrent criterion validity of CD scores were all significant at each age level, with the magnitude ranging from small to large. The diagnostic accuracy of CD scores, as revealed by sensitivity, specificity, and likelihood ratios, was poor. Conclusions The finding on diagnostic accuracy did not support the use of CD for identifying children with LI between ages 4 and 9 years. However, given the attested reliability and validity for CD, reference data of CD from the ENNI database can be used for evaluating children's difficulties with complex syntax and monitoring their change over time. Supplemental Material https://doi.org/10.23641/asha.13172129


VASA ◽  
2015 ◽  
Vol 44 (2) ◽  
pp. 106-114 ◽  
Author(s):  
Adem Adar ◽  
Hakan Erkan ◽  
Tayyar Gokdeniz ◽  
Aysegul Karadeniz ◽  
Ismail G. Cavusoglu ◽  
...  

Background: We aimed to investigate the association between aortic arch and coronary artery calcification (CAC). We postulated that low‐ and high‐risk CAC scores could be predicted with the evaluation of standard chest radiography for aortic arch calcification (AAC). Patients and methods: Consecutive patients who were referred for a multidetector computerized tomography (MDCT) examination were enrolled prospectively. All patients were scanned using a commercially available 64‐slice MDCT scanner for the evaluation of CAC score. A four‐point grading scale (0, 1, 2 and 3) was used to evaluate AAC on the standard posterior‐anterior chest radiography images. Results: The study group consisted of 248 patients. Median age of the study group was 52 (IQR: 10) years, and 165 (67 %) were male. AAC grades (r = 0.676, p < 0.0001) and age (r = 0.518, p < 0.0001) were significantly and positively correlated with CAC score. Presence of AAC was independently associated with the presence of CAC (OR: 11.20, 95 % CI 4.25 to 29.52). An AAC grade of ≥ 2 was the strongest independent predictor of a high‐risk CAC score (OR: 27.42, 95 % CI 6.09 to 123.52). Receiver operating characteristics curve analysis yielded a strong predictive ability of AAC grades for a CAC score of ≥ 100 (AUC = 0.892, P < 0.0001), and ≥ 400 (AUC = 0.894, P < 0.0001). Absence of AAC had a sensitivity, specificity and accuracy of 90 %, 84 % and 89 %, respectively, for a CAC score of < 100. An AAC grade of ≥ 2 predicted a CAC score of ≥400 with a sensitivity, specificity and accuracy of 68 %, 98 % and 95 %, respectively. Conclusions: AAC is a strong and independent predictor of CAC. The discriminative performance of AAC is high in detecting patients with low‐ and high‐risk CAC scores.


1991 ◽  
Vol 30 (03) ◽  
pp. 187-193 ◽  
Author(s):  
H. J. Moens ◽  
J. K. van der Korst

AbstractA Bayesian decision support system was developed for the diagnosis of rheumatic disorders. Knowledge in this system is represented as evidential weights of findings. Simple weights were calculated as the logarithm of likelihood ratios on the basis of 1,000 consecutive patients from a rheumatological clinic. The effect of various methods to improve performance of the system by modification of the weights was studied. Three methods had a mathematical basis; a fourth consisted of weights adapted by a human expert, which allowed inclusion of diagnostic rules such as defined in widely accepted criteria sets. The system’s performance was measured in a test population of 570 different cases from the same clinic and compared with predictions of diagnostic outcome made by rheumatologists. The weights from a human expert gave optimal results (sensitivity 65% and specificity 96%), that were close to the physicians’ predictions (sensitivity 64% and specificity 98%). The methods to measure the performance of the various models used in this study emphasize sensitivity, specificity and the use of receiver operating characteristics.


Author(s):  
Suraj Mathur

This prospective study was done in the Department of Radio diagnosis Govt. Medical College, Kozhikode. A total of 65 patients who were referred to our department with clinical suspicion of endometrial lesions and incidentally detected endometrial lesions on ultrasonography underwent transvaginal ultrasound and subsequent Imaging evaluation of pelvis MRI has very high sensitivity (95%) and specificity (98%) and is almost as accurate (97%) as histopathology in differentiating benign from malignant lesions. Addition of DWI with ADC mapping to conventional MRI increases its accuracy even more. However there is inherent limitation to MRI in detecting carcinoma in situ and micrometastasis. Keywords: TVS, MRI, Sensitivity, Specificity, Histopathology.


1974 ◽  
Vol 75 (4) ◽  
pp. 669-682 ◽  
Author(s):  
K.-G. Thorngren ◽  
L. I. Hansson

ABSTRACT The growth stimulating effect of growth hormone was determined with tetracycline as intravital marker of the longitudinal bone growth of proximal tibia in female Sprague-Dawley rats hypophysectomized at 60 days of age. After a post-operative control period of 15 days growth hormone (NIH-GH-B16) was given daily for 5 or 10 days followed by a 10 day period after its withdrawal. L-thyroxine was given in association with the growth hormone administration to potentiate the growth stimulation. A linear log dose-response relation was found for the two administration models with a high precision. The thyroxine-treatment increased the sensitivity of the bioassay. An administration period of 5 days was found sufficient for the bioassay of growth hormone in thyroxine-treated hypophysectomized rats. Compared with the earlier bioassay methods for growth hormone, the present bioassay is more favourable when all the factors, such as precision, sensitivity, specificity, and administration period are considered.


2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


1958 ◽  
Vol 4 ◽  
pp. 147 ◽  
Author(s):  
IVAN H. SCHEIER
Keyword(s):  

2020 ◽  
Vol 41 (4) ◽  
pp. 240-247
Author(s):  
Lei Yang ◽  
Qingtao Zhao ◽  
Shuyu Wang

Background: Serum periostin has been proposed as a noninvasive biomarker for asthma diagnosis and management. However, its accuracy for the diagnosis of asthma in different populations is not completely clear. Methods: This meta-analysis aimed to evaluate the diagnostic accuracy of periostin level in the clinical determination of asthma. Several medical literature data bases were searched for relevant studies through December 1, 2019. The numbers of patients with true-positive, false-positive, false-negative, and true-negative results for the periostin level were extracted from each individual study. We assessed the risk of bias by using Quality Assessment of Diagnostic Accuracy Studies 2. We used the meta-analysis to produce summary estimates of accuracy. Results: In total, nine studies with 1757 subjects met the inclusion criteria. The pooled estimates of sensitivity, specificity, and diagnostic odds ratios for the detection of asthma were 0.58 (95% confidence interval [CI], 0.38‐0.76), 0.86 (95% CI, 0.74‐0.93), and 8.28 (95% CI, 3.67‐18.68), respectively. The area under the summary receiver operating characteristic curve was 0.82 (95% CI, 0.79‐0.85). And significant publication bias was found in this meta‐analysis (p = 0.39). Conclusion: Serum periostin may be used for the diagnosis of asthma, with moderate diagnostic accuracy.


2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.


Sign in / Sign up

Export Citation Format

Share Document