Effect of Water–Cement Ratio on Linear Shrinkage, Cohesion, Friction Angle and Compressive Strength of Expansive Black Clay of Gombe State, Nigeria

2017 ◽  
Vol 98 (1-2) ◽  
pp. 67-75
Author(s):  
J. Ochepo ◽  
O. Ogwola ◽  
O. Masbeye
2020 ◽  
Vol 862 ◽  
pp. 135-139
Author(s):  
Dhabit Zahin Alias Tudin ◽  
Ahmad Nurfaidhi Rizalman

In this study, crumb rubber was used to partially replaced fine aggregate in mortar mixture by 5, 10, 15 and 20 volume percentage (vol%) with untreated and NaOH-treated crumb rubber. There were three (3) different water-cement ratio used which are 0.45, 0.50 and 0.55. Thus, the total number of mixtures was 27. The mortars were tested for flowability, compressive strength, flexural strength and density. Based on the results, higher water cement ratio and percentage of crumb rubber replacement increased the flowability but lowered the density, compressive strength and flexural strength of the rubberized mortar. It was also discovered that the significant effect of water-cement ratio on the fresh and hardened properties of the rubberized mortar was due to the water content in the mixture. Meanwhile, the use of NaOH as treatment to crumb rubber improved the flowability, compressive strength and flexural strength of the rubberized mortar.


2010 ◽  
Vol 168-170 ◽  
pp. 2116-2120
Author(s):  
Jian Chao Dou ◽  
Jian Sen Yang

The effect of water-cement ratio, air content, silica fume and sand ratio of concrete on the coefficient of linear expansion(CLE) was studied by orthogonal experiment. The results show that under a certain amount of cement material, CLE of concrete increase as the water-cement ratio increases and the effect of water-cement ratio on CLE of concrete is remarkable; with the increase of blending ratio of silica fume, the CLE of concrete increases; the CLE of concrete reduces with 3.5% air content in concrete, but rebound with 6% air content in concrete; with the sand rate increases, CLE of concrete increases; CLE per unit compressive strength of concrete with silica fume decreases with increase of silica fume content; CLE per unit compressive strength of concrete with air content increase when air content increase.


2019 ◽  
Vol 25 (5) ◽  
pp. 79-86 ◽  
Author(s):  
Ziwar Zebari

This study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University.  The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged between (3.89-4.66km/s) and (17.74-40.56MPa) respectively. The experimental results showed that although the UPV and the compressive strength of concrete are related, also, the UPV and compressive strength have a relation with the rate of the water-cement ratio of concrete.  


Buildings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 44
Author(s):  
Fernando A. N. Silva ◽  
João M. P. Q. Delgado ◽  
Rosely S. Cavalcanti ◽  
António C. Azevedo ◽  
Ana S. Guimarães ◽  
...  

The work presents the results of an experimental campaign carried out on concrete elements in order to investigate the potential of using artificial neural networks (ANNs) to estimate the compressive strength based on relevant parameters, such as the water–cement ratio, aggregate–cement ratio, age of testing, and percentage cement/metakaolin ratios (5% and 10%). We prepared 162 cylindrical concrete specimens with dimensions of 10 cm in diameter and 20 cm in height and 27 prismatic specimens with cross sections measuring 25 and 50 cm in length, with 9 different concrete mixture proportions. A longitudinal transducer with a frequency of 54 kHz was used to measure the ultrasonic velocities. An ANN model was developed, different ANN configurations were tested and compared to identify the best ANN model. Using this model, it was possible to assess the contribution of each input variable to the compressive strength of the tested concretes. The results indicate an excellent performance of the ANN model developed to predict compressive strength from the input parameters studied, with an average error less than 5%. Together, the water–cement ratio and the percentage of metakaolin were shown to be the most influential factors for the compressive strength value predicted by the developed ANN model.


2013 ◽  
Vol 648 ◽  
pp. 108-111
Author(s):  
Qi Jin Li ◽  
Guo Zhong Li

The construction waste was processed into recycled aggregate to produce solid construction waste brick with grade of MU20. The preparation process of recycled aggregate and the optimal value of mass ratio of water to cement (water cement ratio) and mass ratio of recycled aggregate to cement was studied. The results shows that when the water cement ratio is 0.86 and the mass ratio of recycled aggregate to cement is 5.5 and the dosage of activator is 0.25% (mass fraction with recycled aggregate), the compressive strength of sample is 22.5MPa and can be satisfied with the requirement of MU20 solid concrete brick.


Sign in / Sign up

Export Citation Format

Share Document