scholarly journals A study on the effect of ultrashort pulsed laser texturing on the microstructure and properties of metastable S phase layer formed on AISI 316L surfaces

2020 ◽  
Vol 511 ◽  
pp. 145557
Author(s):  
Behnam Dashtbozorg ◽  
Xiaoying Li ◽  
Jean–Michel Romano ◽  
Antonio Garcia–Giron ◽  
Rachel L. Sammons ◽  
...  
Coatings ◽  
2018 ◽  
Vol 8 (12) ◽  
pp. 456 ◽  
Author(s):  
Shinichiro Adachi ◽  
Nobuhiro Ueda

Cold-sprayed AISI 316L stainless steel coatings are treated to form an austenite phase with excessive dissolved nitrogen (known as the S-phase) by plasma nitriding at temperatures below 450 °C. The S-phase is a hard and wear-resistant layer with high corrosion resistance. However, the S-phase layer formed after only nitriding is thin and the hardness abruptly decreases at a certain depth; it lacks mechanical reliability. We examined two types of combined low-temperature plasma treatment to enhance the mechanical reliability of the S-phase layer: (i) sequential and (ii) simultaneous. In the sequential plasma treatment, the carburizing step was followed by nitriding. In the simultaneous treatment, the nitriding and carburizing steps were conducted at the same time. Both combined plasma treatments succeeded in thickening the S-phase layers and changed the hardness depth profiles to decrease smoothly. In addition, anodic polarization measurements indicated that sequential treatment involving carburizing followed by nitriding for 2 h each resulted in high corrosion resistance.


2008 ◽  
Vol 36 (Supplement) ◽  
pp. 201-202
Author(s):  
Yasuhiro Awatsuji ◽  
Kenzo Nishio ◽  
Shogo Ura ◽  
Toshihiro Kubota

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Samuel McPhee ◽  
Alexander Groetsch ◽  
Jonathan D. Shephard ◽  
Uwe Wolfram

AbstractThe underlying constraint of ultrashort pulsed laser ablation in both the clinical and micromachining setting is the uncertainty regarding the impact on the composition of material surrounding the ablated region. A heat model representing the laser-tissue interaction was implemented into a finite element suite to assess the cumulative temperature response of bone during ultrashort pulsed laser ablation. As an example, we focus on the extraction of mineralised collagen fibre micropillars. Laser induced heating can cause denaturation of the collagen, resulting in ultrastructural loss which could affect mechanical testing results. Laser parameters were taken from a used micropillar extraction protocol. The laser scanning pattern consisted of 4085 pulses, with a final radial pass being 22 $$\upmu {\text {m}}$$ μ m away from the micropillar. The micropillar temperature was elevated to 70.58 $$^{\circ }{\text {C}}$$ ∘ C , remaining 79.42 $$^{\circ }{\text {C}}$$ ∘ C lower than that of which we interpret as an onset for denaturation. We verified the results by means of Raman microscopy and Energy Dispersive X-ray Microanalysis and found the laser-material interaction had no effect on the collagen molecules or mineral nanocrystals that constitute the micropillars. We, thus, show that ultrashort pulsed laser ablation is a safe and viable tool to fabricate bone specimens for mechanical testing at the micro- and nanoscale and we provide a computational model to efficiently assess this.


2021 ◽  
pp. 161437
Author(s):  
J. Antonowicz ◽  
P. Zalden ◽  
K. Sokolowski-Tinten ◽  
K. Georgarakis ◽  
R. Minikayev ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document