A cooled CCD camera-based protocol provides an effective solution for in vitro monitoring of luciferase

2015 ◽  
Vol 458 (3) ◽  
pp. 543-548 ◽  
Author(s):  
Amirali Afshari ◽  
Claudia Uhde-Stone ◽  
Biao Lu
1996 ◽  
Vol 23 (1) ◽  
pp. 75 ◽  
Author(s):  
SR Mudge ◽  
WR Lewis-Henderson ◽  
RG Birch

Luciferase genes from Vibrio harveyi (luxAB) and firefly (luc) were introduced into E. coli, Agrobacteriurn, Arabidopsis and tobacco. Transformed bacteria and plants were quantitatively assayed for luciferase activity using a range of in vitro and in vivo assay conditions. Both lux and luc proved efficient reporter genes in bacteria, although it is important to be aware that the sensitive assays may detect expression due to readthrough from distant promoters. LUX activity was undetectable by liquid nitrogen-cooled CCD camera assays on intact tissues of plants which showed strong luxAB expression by in vitro assays. The decanal substrate for the lux assay was toxic to many plant tissues, and caused chemiluminescence in untransformed Arabidopsis leaves. These are serious limitations to application of the lux system for sensitive, non-toxic assays of reporter gene expression in plants. In contrast, LUC activity was readily detectable in intact tissues of all plants with luc expression detectable by luminometer assays on cell extracts. Image intensities of luc-expressing leaves were commonly two to four orders of magnitude above controls under the CCD camera. Provided adequate penetration of the substrate luciferin is obtained, luc is suitable for applications requiring sensitive, non-toxic assays of reporter gene expression in plants.


Author(s):  
W.F. Marshall ◽  
K. Oegema ◽  
J. Nunnari ◽  
A.F. Straight ◽  
D.A. Agard ◽  
...  

The ability to image cells in three dimensions has brought about a revolution in biological microscopy, enabling many questions to be asked which would be inaccessible without this capability. There are currently two major methods of three dimensional microscopy: laser-scanning confocal microscopy and widefield-deconvolution microscopy. The method of widefield-deconvolution uses a cooled CCD to acquire images from a standard widefield microscope, and then computationally removes out of focus blur. Using such a scheme, it is easy to acquire time-lapse 3D images of living cells without killing them, and to do so for multiple wavelengths (using computer-controlled filter wheels). Thus, it is now not only feasible, but routine, to perform five dimensional microscopy (three spatial dimensions, plus time, plus wavelength).Widefield-deconvolution has several advantages over confocal microscopy. The two main advantages are high speed of acquisition (because there is no scanning, a single optical section is acquired at a time by using a cooled CCD camera) and the use of low excitation light levels Excitation intensity can be much lower than in a confocal microscope for three reasons: 1) longer exposures can be taken since the entire 512x512 image plane is acquired in parallel, so that dwell time is not an issue, 2) the higher quantum efficiently of a CCD detect over those typically used in confocal microscopy (although this is expected to change due to advances in confocal detector technology), and 3) because no pinhole is used to reject light, a much larger fraction of the emitted light is collected. Thus we can typically acquire images with thousands of photons per pixel using a mercury lamp, instead of a laser, for illumination. The use of low excitation light is critical for living samples, and also reduces bleaching. The high speed of widefield microscopy is also essential for time-lapse 3D microscopy, since one must acquire images quickly enough to resolve interesting events.


Author(s):  
E. D. Salmon ◽  
J. C. Waters ◽  
C. Waterman-Storer

We have developed a multi-mode digital imaging system which acquires images with a cooled CCD camera (Figure 1). A multiple band pass dichromatic mirror and robotically controlled filter wheels provide wavelength selection for epi-fluorescence. Shutters select illumination either by epi-fluorescence or by transmitted light for phase contrast or DIC. Many of our experiments involve investigations of spindle assembly dynamics and chromosome movements in live cells or unfixed reconstituted preparations in vitro in which photodamage and phototoxicity are major concerns. As a consequence, a major factor in the design was optical efficiency: achieving the highest image quality with the least number of illumination photons. This principle applies to both epi-fluorescence and transmitted light imaging modes. In living cells and extracts, microtubules are visualized using X-rhodamine labeled tubulin. Photoactivation of C2CF-fluorescein labeled tubulin is used to locally mark microtubules in studies of microtubule dynamics and translocation. Chromosomes are labeled with DAPI or Hoechst DNA intercalating dyes.


2001 ◽  
Author(s):  
Naoki Saitoh ◽  
Kenro Kuroki ◽  
Kenji Kurosawa ◽  
Norimitsu Akiba

2007 ◽  
Vol 19 (5) ◽  
pp. 519-523 ◽  
Author(s):  
Masayasu Suzuki ◽  
◽  
Toyohiro Ohshima ◽  
Shintaro Hane ◽  
Yasunori Iribe ◽  
...  

Evaluating cell activity and functions in different-sized cell chambers requires multiscale sensing. We have been developing multiscale biosensing applied from 10 µm to 1 mm. We measured mouse IgG in micro wells using a high-resolution two-dimensional surface plasmon resonance (SPR) imaging affinity sensor. This sensor uses high refractive optics, a 1X to 7X microscopic lens, and a cooled CCD camera. The micro-well array was prepared with a PDMS film on gold sensor film. Protein A immobilized on sensor film was used for IgG recognition. SPR sensitivity was dramatically decreased with 10 and 8.5 µm microwells. To improve sensor sensitivity, we optimized the sensor’s measurement angle and exposure time, enabling mouse IgG to be detected in wells of 1 mm, 30 µm, and 10 µm using the same 2D-SPR imaging sensor and measurement protocol. These results show the feasibility of multiscale biosensing use in antibody production in a micro well or a cell chamber.


2000 ◽  
Author(s):  
P. L. Kopsombut ◽  
D. Willis ◽  
A. E. Schen ◽  
L. X. Xu ◽  
X. Xu

Abstract Along with rapid development of diagnostic and therapeutic applications of lasers in medicine, optical properties of various biological tissues have been extensively studied [1]. Most of the studies were performed in vitro owing to the complexity involved in in vivo measurement. To date, it is well understood that living tissue is an absorbing and scattering heterogeneous medium because of its complex structures including blood network. The transport theory cannot be readily used due to the heterogeneity and the absence of the optical properties of living tissues [2]. In this research, we have developed a procedure for measuring the total attenuation coefficient (μ1) of the exteriorized rat 2-D spinotrapezius muscle in the wavelength ranged from 480–560 nm using the collimated light from a Nitrogen-pumped dye laser and a high-sensitivity CCD camera.


1997 ◽  
Vol 3 (S2) ◽  
pp. 1125-1126
Author(s):  
S.J. Pan ◽  
A. Shih ◽  
W.S. Liou ◽  
M.S. Park ◽  
G. Wang ◽  
...  

An experimental X-ray cone-beam microtomographic imaging system utilizing a generalized Feldkamp reconstruction algorithm has been developed in our laboratory. This microtomographic imaging system consists of a conventional dental X-ray source (Aztech 65, Boulder, CO), a sample position and rotation stage, an X-ray scintillation phosphor screen, and a high resolution slow scan cooled CCD camera (Kodak KAF 1400). A generalized Feldkamp cone-beam algorithm was used to perform tomographic reconstruction from cone-beam projection data. This algorithm was developed for various hardware configuration to perform reconstruction of spherical, rod-shaped and plate-like specimen.A test sample consists of 8 glass beads (approx. 800μm in diameter) dispersed in an epoxy-filled #0 gelatin capsule. One hundred X-ray projection images were captured equal angularly (at 3.6 degree spacing) by the cooled CCD camera at a of 1317×967 (17×17mm2) pixels with 12-bit dynamic range. Figure 1 shows a 3D isosurface rendering of the test sample. The eight glass beads and trapped air bubbles (arrows) in the epoxy resin (e) are clearly visible.


1997 ◽  
Vol 3 (S2) ◽  
pp. 211-212
Author(s):  
C. M. Waterman-Storer ◽  
E. D. Salmon

We have developed a multi-mode digital imaging system (1-3) which acquires images with a 12 bit cooled CCD camera. A multiple band pass dichromatic mirror and robotically controlled excitation filter wheels provide rapid wavelength selection for epi-fluorescence with DAPI, fluorescein or GFP and X-rhodamine fluorophores while maintaining image registration on the cooled CCD detector. Shutters select illumination either by epi-fluorescence or by transmitted light for phase contrast or DIC. A robotically controlled emission filter wheel in front of the CCD camera inserts an analyzer in the light path for DIC imaging. To maximize fluorescence light intensity, the analyzer is removed and an optical flat of equivalent optical thickness is inserted for fluorescence imaging. A slider is inserted at the field diaphragm position of the fluorescence epi-illuminator to provide in-focus slit and spot targets for 360 nm photoactivation of “caged” fluorophores. The microscope system is robotically controlled and image acquisition and analysis is performed using MetaMorph™ digital imaging software.


2004 ◽  
Vol 31 (9) ◽  
pp. 2549-2551 ◽  
Author(s):  
E. M. Franken ◽  
J. C. J. de Boer ◽  
J. C. Barnhoorn ◽  
B. J. M. Heijmen

1991 ◽  
Vol 9 (1) ◽  
pp. 158-159 ◽  
Author(s):  
B. D. Carter ◽  
M. C. B. Ashley

AbstractWe describe the application of Peltier effect cooling to charge coupled device (CCD) detectors. We are developing this technique to produce a CCD camera which requires low maintenance, yet has sufficiently small dark-current for long exposure imaging. This camera will be used in an automated imaging telescope at Siding Spring Observatory. The design principles used to maximise cooling of the detector, and hence minimise dark-current, are discussed. A small dark-current can be obtained only if great care is taken to reduce or eliminate convective, conductive and radiative heating of the chip. In addition, a path of high thermal conductivity must be provided for the heat removed from the CCD. A recent laboratory test of our cooling system demonstrates that careful design can lead to sufficiently low CCD dark-current for many astronomical applications.