Pull-out and bond-slip performance of steel fibers with various ends shapes embedded in polymer-modified concrete

Author(s):  
Jamshid Esmaeili ◽  
Keyvan Andalibi ◽  
Osman Gencel ◽  
Farshid Khosravi Maleki ◽  
Vahid Arab Maleki
1990 ◽  
Vol 211 ◽  
Author(s):  
Gilles Chanvillard ◽  
Pierre-Claude Aitcin

AbstractThe pull-out behavior of non-straight steel fibers cannot always be analyzed solely in terms of bonding. Rather, it is necessary to take into account the mechanical anchorage provided by the fiber geometry.It is shown in this paper, that in the case of non-straight steel fibers a strong interaction exists between bonding and anchorage. A micro-mechanical model, based on the dissipation of energy during slipping of the fiber is proposed. In this model, bonding is included on the basis of the Coulomb friction law, without reference to a bond-slip law; mechanical anchorage is modelled from plastic deformation of the fiber.With this model, it is possible to evaluate the significance of some physical parameters such as the water/cement ratio of the matrix, the fiber's geometry and the steel properties. Moreover, this model provides a rational basis for the optimization of the fiber-cementitious matrix interaction from an energy point of view.


2021 ◽  
Vol 16 (59) ◽  
pp. 49-61
Author(s):  
Zhengbing Xia ◽  
Xiaofang Duan

In order to promote the application of steel fiber recycled concrete in projects such as roads and bridges, 25 groups of steel fiber recycled concrete with different mix proportions were designed, taking the replacement rate of recycled aggregate and the volume fraction of steel fibers as experimental parameters, and 77 steel bars and steel fiber recycled concrete bonded specimens were made and pasted with strain gauges for the pull-out test. The research results showed that the greater the replacement rate of recycled aggregates was, the lower the bond strength between steel bars and steel fiber recycled concrete was; in the range of 0~1.2%, the higher the mixing amount of steel fibers was, the greater the bond strength of the specimen was; in the range of 0~1.6%, the higher the mixing amount of steel fibers was, the greater the slip value of the specimen under the peak load was; the addition of steel fibers improved the failure behavior of the recycled concrete pull-out specimens; the test specimens mainly had pull-out failure when the mixing amount of steel fibers was 1.2% and 1.6%. Finally, this study modified the bond-slip constitutive relationship model of steel and steel fiber recycled concrete, analyzed the influence of the replacement rate of recycled aggregate and the mix proportion of steel fibers on its bonding performance, and compared the results with the test results. The results demonstrate that the test curve is in good agreement with the fitted curve, which can provide theoretical support for engineering applications. 


Author(s):  
Katarzyna Zdanowicz ◽  
Boso Schmidt ◽  
Hubert Naraniecki ◽  
Steffen Marx

<p>The bond behaviour of concrete specimens with carbon textile reinforcement was investigated in the presented research programme. Pull-out specimens were cast from self-compacting concrete with expansive admixtures and in this way chemical prestress was introduced. The aim of the research was to compare bond behaviour between prestressed specimens and non-prestressed control specimens. During pull-out tests, the pull-out force and notch opening were measured with a load cell and laser sensors. Further, bond - slip and pull-out force - crack width relationships were drawn and compared for prestressed and non-prestressed specimens. Chemically prestressed specimens reached 24% higher bond strength than non-prestressed ones. It can be therefore concluded, that chemical prestressing positively influences the bond behaviour of concrete with textile reinforcement and thus better utilisation of its properties can be provided.</p>


2018 ◽  
Vol 40 (7) ◽  
pp. 2840-2849
Author(s):  
Qingping Jin ◽  
Guangbo Wang ◽  
Tingying Liang ◽  
Peixia Chen
Keyword(s):  

2002 ◽  
Vol 29 (2) ◽  
pp. 191-200 ◽  
Author(s):  
M Alavi-Fard ◽  
H Marzouk

Structures located in seismic zones require significant ductility. It is necessary to examine the bond slip characteristics of high strength concrete under cyclic loading. The cyclic bond of high strength concrete is investigated under different parameters, including load history, confining reinforcement, bar diameter, concrete strength, and the rate of pull out. The bond strength, cracking, and deformation are highly dependent on the bond slip behavior between the rebar and the concrete under cyclic loading. The results of cyclic testing indicate that an increase in cyclic displacement will lead to more severe bond damage. The slope of the bond stress – displacement curve can describe the influence of the rate of loading on the bond strength in a cyclic test. Specimens with steel confinement sustained a greater number of cycles than the specimens without steel confinement. It has been found that the maximum bond strength increases with an increase in concrete strength. Cyclic loading does not affect the bond strength of high strength concrete as long as the cyclic slip is less than the maximum slip for monotonic loading. The behavior of high strength concrete under a cyclic load is slightly different from that of normal strength concrete.Key words: bond, high strength, cyclic loading, bar spacing, loading rate, failure mechanism.


2017 ◽  
Vol 747 ◽  
pp. 319-325 ◽  
Author(s):  
Matteo Maragna ◽  
Cristina Gentilini ◽  
Giovanni Castellazzi ◽  
Christian Carloni

In this paper, the preliminary results of a series of pull-out tests conducted on mortar cylinders with embedded bars are presented. The bars are made of high strength stainless steel and are of helical shape to increase mechanical interlocking with the surrounding mortar. Usually, such bars are employed in situ to realize structural repointing in the case of fair-faced masonry walls. To this aim, they are inserted in the mortar bed joints of masonry for providing tensile strength to the walls and with the function of crack stitching. The aim of the present experimental tests is to determine the bond-slip relationship for bars embedded in masonry. Firstly, pull-out tests are conducted on mortar cylinders considering different embedded lengths of the bars. Further tests are on-going on masonry specimens with bars embedded in the mortar joints. An analytical investigation is also carried out for the interpretation of the pull-out test results.


2021 ◽  
Vol 331 ◽  
pp. 05012
Author(s):  
Patria Kusumaningrum ◽  
Gigih Muslim Prayogo ◽  
Sri Tudjono

A finite element study carried out using LS DYNA and aimed to simulate the monotonic pull-out test of deformed steel rebar embedded in concrete is presented in this paper. Three models of the interface between deformed steel rebar and well-confined concrete, i.e. perfect bond model and two bond-slip models are observed and compared. Bond stress-slip response and rebar stress-slip response obtained numerically are validated with experimental data and empirical equations available from the literature. The full bond model overestimates the response, providing higher rebar stress. In the bond-slip models, good agreement is observed between numerical and experimental bond stress and rebar Stress–slip responses. The empirical equation of bond-slip proposed by Murcia-Delso and Shing (2014) is found to overestimate the peak bond stress.


Sign in / Sign up

Export Citation Format

Share Document