A high signal-to-background ratio H2S-specific fluorescent probe based on nucleophilic substitution and its bioimaging for generation H2S induced by Ca2+ in vivo

2019 ◽  
Vol 171 ◽  
pp. 107755 ◽  
Author(s):  
Jin Kang ◽  
Fangjun Huo ◽  
Yishan Yao ◽  
Caixia Yin
2020 ◽  
Vol 4 (6) ◽  
pp. 1634-1642 ◽  
Author(s):  
Haiyan Tian ◽  
Dongyu Li ◽  
Xi Tang ◽  
Yubo Zhang ◽  
Zhiyong Yang ◽  
...  

DCPE-TPA exhibits three morphologies with high quantum yields and nanoparticles of DCPE-TPA are utilized for in vivo 3PF imaging, achieving a penetration depth of 300 μm with a high resolution of 1.8 μm and a high signal-to-background ratio of 14.


The Analyst ◽  
2017 ◽  
Vol 142 (14) ◽  
pp. 2624-2630 ◽  
Author(s):  
Dan Pan ◽  
Fengyan Luo ◽  
Xianjun Liu ◽  
Wei Liu ◽  
Wen Chen ◽  
...  

We have developed a novel TPE fluorescent probe (Q3CA-P), with a long Stokes shift and a high signal-to-background ratio, for hNQO1 detection and imaging.


2020 ◽  
Author(s):  
Shatadru Chakravarty ◽  
Jeremy Hix ◽  
Kaitlyn Wieweora ◽  
Maximilian Volk ◽  
Elizabeth Kenyon ◽  
...  

Here we describe the synthesis, characterization and in vitro and in vivo performance of a series of tantalum oxide (TaOx) based nanoparticles (NPs) for computed tomography (CT). Five distinct versions of 9-12 nm diameter silane coated TaOx nanocrystals (NCs) were fabricated by a sol-gel method with varying degrees of hydrophilicity and with or without fluorescence, with the highest reported Ta content to date (78%). Highly hydrophilic NCs were left bare and were evaluated in vivo in mice for micro-CT of full body vasculature, where following intravenous injection, TaOx NCs demonstrate high CT contrast, circulation in blood for ~ 3 h, and eventual accumulation in RES organs; and following injection locally in the mammary gland, where the full ductal tree structure can be clearly delineated. Partially hydrophilic NCs were encapsulated within mesoporous silica nanoparticles (MSNPs; TaOx@MSNPs) and hydrophobic NCs were encapsulated within poly(lactic-co-glycolic acid) (PLGA; TaOx@PLGA) NPs, serving as potential CT-imagable drug delivery vehicles. Bolus intramuscular injections of TaOx@PLGA NPs and TaOx@MSNPs to mimic the accumulation of NPs at a tumor site produce high signal enhancement in mice. In vitro studies on bare NCs and formuated NPs demonstrate high cytocompatibility and low dissolution of TaOx. This work solidifies that TaOx-based NPs are versatile contrast agents for CT.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2605
Author(s):  
Ashley Novais ◽  
Carlos Calaza ◽  
José Fernandes ◽  
Helder Fonseca ◽  
Patricia Monteiro ◽  
...  

Multisite neural probes are a fundamental tool to study brain function. Hybrid silicon/polymer neural probes combine rigid silicon and flexible polymer parts into one single device and allow, for example, the precise integration of complex probe geometries, such as multishank designs, with flexible biocompatible cabling. Despite these advantages and benefiting from highly reproducible fabrication methods on both silicon and polymer substrates, they have not been widely available. This paper presents the development, fabrication, characterization, and in vivo electrophysiological assessment of a hybrid multisite multishank silicon probe with a monolithically integrated polyimide flexible interconnect cable. The fabrication process was optimized at wafer level, and several neural probes with 64 gold electrode sites equally distributed along 8 shanks with an integrated 8 µm thick highly flexible polyimide interconnect cable were produced. The monolithic integration of the polyimide cable in the same fabrication process removed the necessity of the postfabrication bonding of the cable to the probe. This is the highest electrode site density and thinnest flexible cable ever reported for a hybrid silicon/polymer probe. Additionally, to avoid the time-consuming bonding of the probe to definitive packaging, the flexible cable was designed to terminate in a connector pad that can mate with commercial zero-insertion force (ZIF) connectors for electronics interfacing. This allows great experimental flexibility because interchangeable packaging can be used according to experimental demands. High-density distributed in vivo electrophysiological recordings were obtained from the hybrid neural probes with low intrinsic noise and high signal-to-noise ratio (SNR).


Talanta ◽  
2021 ◽  
pp. 122519
Author(s):  
Yi Li ◽  
Chang Li ◽  
Yuanbiao Tu ◽  
Ji Tao ◽  
Peifei Liu ◽  
...  

2019 ◽  
Vol 12 (06) ◽  
pp. 1950012 ◽  
Author(s):  
Hequn Zhang ◽  
Weisi Xie ◽  
Ming Chen ◽  
Liang Zhu ◽  
Zhe Feng ◽  
...  

Rodents are popular biological models for physiological and behavioral research in neuroscience and rats are better models than mice due to their higher genome similarity to human and more accessible surgical procedures. However, rat brain is larger than mice brain and it needs powerful imaging tools to implement better penetration against the scattering of the thicker brain tissue. Three-photon fluorescence microscopy (3PFM) combined with near-infrared (NIR) excitation has great potentials for brain circuits imaging because of its abilities of anti-scattering, deep-tissue imaging, and high signal-to-noise ratio (SNR). In this work, a type of AIE luminogen with red fluorescence was synthesized and encapsulated with Pluronic F-127 to make up form nanoparticles (NPs). Bright DCDPP-2TPA NPs were employed for in vivo three-photon fluorescent laser scanning microscopy of blood vessels in rats brain under 1550[Formula: see text]nm femtosecond laser excitation. A fine three-dimensional (3D) reconstruction up to the deepness of 600[Formula: see text][Formula: see text]m was achieved and the blood flow velocity of a selected vessel was measured in vivo as well. Our 3PFM deep brain imaging method simultaneously recorded the morphology and function of the brain blood vessels in vivo in the rat model. Using this angiography combined with the arsenal of rodent’s brain disease, models can accelerate the neuroscience research and clinical diagnosis of brain disease in the future.


2017 ◽  
Vol 28 (5) ◽  
pp. 2969-2977
Author(s):  
K. S. Uma Suganya ◽  
K. Govindaraju ◽  
C. Veena Vani ◽  
R. Kirubagaran ◽  
T. Ashok Kumar ◽  
...  

Author(s):  
Xiufeng Li ◽  
Victor T C Tsang ◽  
Lei Kang ◽  
Yan Zhang ◽  
Terence T W Wong

AbstractLaser diodes (LDs) have been considered as cost-effective and compact excitation sources to overcome the requirement of costly and bulky pulsed laser sources that are commonly used in photoacoustic microscopy (PAM). However, the spatial resolution and/or imaging speed of previously reported LD-based PAM systems have not been optimized simultaneously. In this paper, we developed a high-speed and high-resolution LD-based PAM system using a continuous wave LD, operating at a pulsed mode, with a repetition rate of 30 kHz, as an excitation source. A hybrid scanning mechanism that synchronizes a one-dimensional galvanometer mirror and a two-dimensional motorized stage is applied to achieve a fast imaging capability without signal averaging due to the high signal-to-noise ratio. By optimizing the optical system, a high lateral resolution of 4.8 μm has been achieved. In vivo microvasculature imaging of a mouse ear has been demonstrated to show the high performance of our LD-based PAM system.


Sign in / Sign up

Export Citation Format

Share Document