scholarly journals A fuzzy FMEA assessment of hydroelectric earth dam failure modes: A case study in Central Brazil

2021 ◽  
Vol 7 ◽  
pp. 4412-4424
Author(s):  
José Roberto Ribas ◽  
Juliana Crenitte Ribas Severo ◽  
Luciana Fernandes Guimarães ◽  
Kim Parente Currlin Perpetuo
2021 ◽  
Vol 11 (8) ◽  
pp. 3726
Author(s):  
Radu Godina ◽  
Beatriz Gomes Rolis Silva ◽  
Pedro Espadinha-Cruz

The growing competitiveness in the automotive industry and the strict standards to which it is subject, require high quality standards. For this, quality tools such as the failure mode and effects analysis (FMEA) are applied to quantify the risk of potential failure modes. However, for qualitative defects with subjectivity and associated uncertainty, and the lack of specialized technicians, it revealed the inefficiency of the visual inspection process, as well as the limitations of the FMEA that is applied to it. The fuzzy set theory allows dealing with the uncertainty and subjectivity of linguistic terms and, together with the expert systems, allows modeling of the knowledge involved in tasks that require human expertise. In response to the limitations of FMEA, a fuzzy FMEA system was proposed. Integrated in the design, measure, analyze, improve and control (DMAIC) cycle, the proposed system allows the representation of expert knowledge and improves the analysis of subjective failures, hardly detected by visual inspection, compared to FMEA. The fuzzy FMEA system was tested in a real case study at an industrial manufacturing unit. The identified potential failure modes were analyzed and a fuzzy risk priority number (RPN) resulted, which was compared with the classic RPN. The main results revealed several differences between both. The main differences between fuzzy FMEA and classical FMEA come from the non-linear relationship between the variables and in the attribution of an RPN classification that assigns linguistic terms to the results, thus allowing a strengthening of the decision-making regarding the mitigation actions of the most “important” failure modes.


Author(s):  
Erick Kim ◽  
Kamjou Mansour ◽  
Gil Garteiz ◽  
Javeck Verdugo ◽  
Ryan Ross ◽  
...  

Abstract This paper presents the failure analysis on a 1.5m flex harness for a space flight instrument that exhibited two failure modes: global isolation resistances between all adjacent traces measured tens of milliohm and lower resistance on the order of 1 kiloohm was observed on several pins. It shows a novel method using a temperature controlled air stream while monitoring isolation resistance to identify a general area of interest of a low isolation resistance failure. The paper explains how isolation resistance measurements were taken and details the steps taken in both destructive and non-destructive analyses. In theory, infrared hotspot could have been completed along the length of the flex harness to locate the failure site. However, with a field of view of approximately 5 x 5 cm, this technique would have been time prohibitive.


Author(s):  
Martin Versen ◽  
Dorina Diaconescu ◽  
Jerome Touzel

Abstract The characterization of failure modes of DRAM is often straight forward if array related hard failures with specific addresses for localization are concerned. The paper presents a case study of a bitline oriented failure mode connected to a redundancy evaluation in the DRAM periphery. The failure mode analysis and fault modeling focus both on the root-cause and on the test aspects of the problem.


Author(s):  
Bhanu P. Sood ◽  
Michael Pecht ◽  
John Miker ◽  
Tom Wanek

Abstract Schottky diodes are semiconductor switching devices with low forward voltage drops and very fast switching speeds. This paper provides an overview of the common failure modes in Schottky diodes and corresponding failure mechanisms associated with each failure mode. Results of material level evaluation on diodes and packages as well as manufacturing and assembly processes are analyzed to identify a set of possible failure sites with associated failure modes, mechanisms, and causes. A case study is then presented to illustrate the application of a systematic FMMEA methodology to the analysis of a specific failure in a Schottky diode package.


2021 ◽  
Vol 1 ◽  
pp. 81-90
Author(s):  
John Bake Sakwe ◽  
Marcus Pereira Pessoa ◽  
Sipke Hoekstra

AbstractWith the quest for enhancing competitive position, fulfilling customer and sustainability demands, increasing profitability, asset manufacturing companies are now adapting assets towards product service systems (PSS) offered through performance contracts. Despite several benefits, the shift to performance PSS exposes industrial asset manufacturers' to performance challenges and risks. Currently, PSS designers face a challenge to exhaustively identify potential failures during PSS development. Knowledge of Product failures is critical prior to the engineering of PSS. This paper proposes a failure modes and effects analysis (FMEA) method to support designers' prioritise critical failures in performance PSS development. A case study of an optical sorting machine is used to demonstrate the method's application.


Author(s):  
Elena Bartolomé ◽  
Paula Benítez

Failure Mode and Effect Analysis (FMEA) is a powerful quality tool, widely used in industry, for the identification of failure modes, their effects and causes. In this work, we investigated the utility of FMEA in the education field to improve active learning processes. In our case study, the FMEA principles were adapted to assess the risk of failures in a Mechanical Engineering course on “Theory of Machines and Mechanisms” conducted through a project-based, collaborative “Study and Research Path (SRP)” methodology. The SRP is an active learning instruction format which is initiated by a generating question that leads to a sequence of derived questions and answers, and combines moments of study and inquiry. By applying the FMEA, the teaching team was able to identify the most critical failures of the process, and implement corrective actions to improve the SRP in the subsequent year. Thus, our work shows that FMEA represents a simple tool of risk assesment which can serve to identify criticality in educational process, and improve the quality of active learning.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3305
Author(s):  
Katarzyna Pietrucha-Urbanik ◽  
Barbara Tchórzewska-Cieślak ◽  
Mohamed Eid

Initiated by a case study to assess the effectiveness of the modernisation actions undertaken in a water supply system, some R&D activities were conducted to construct a global predictive model, based on the available operational failure and recovery data. The available operational data, regarding the water supply system, are the pipes’ diameter, failure modes, materials, functional conditions, seasonality, and the number of failures and time-to-recover intervals. The operational data are provided by the water company responsible of the supply system. A predictive global model is proposed based on the output of the operational data statistical assessment. It should assess the expected effectiveness of decisions taken in support of the modernisation and the extension plan.


Author(s):  
Dennis B. Brickman ◽  
Ralph L. Barnett

Abstract A fatal accident occurred when a right angle gear box on an auger elevator disintegrated freeing the outboard end of a rotating PTO shaft. The tractor, acting as a stationary power source, flailed the PTO shaft which then struck and killed a farmer. No similar occurrences have been reported for the nearly 2000 similar units which have been used for over a decade. This paper studies a number of fundamental failure modes in order to determine which failure modes created the accident. Systematic analysis showed that the accident was caused by unusual misuse of the product. Known safety control concepts do not preclude this unforeseeable event.


Sign in / Sign up

Export Citation Format

Share Document