Ionizing radiation doses during lower limb torsion and anteversion measurements by EOS stereoradiography and computed tomography

2014 ◽  
Vol 83 (2) ◽  
pp. 371-377 ◽  
Author(s):  
Cyrille Delin ◽  
Stéphane Silvera ◽  
Céline Bassinet ◽  
Philippe Thelen ◽  
Jean-Luc Rehel ◽  
...  
2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Richard G. Kavanagh ◽  
John O’Grady ◽  
Brian W. Carey ◽  
Patrick D. McLaughlin ◽  
Siobhan B. O’Neill ◽  
...  

Magnetic resonance imaging (MRI) is the mainstay method for the radiological imaging of the small bowel in patients with inflammatory bowel disease without the use of ionizing radiation. There are circumstances where imaging using ionizing radiation is required, particularly in the acute setting. This usually takes the form of computed tomography (CT). There has been a significant increase in the utilization of computed tomography (CT) for patients with Crohn’s disease as patients are frequently diagnosed at a relatively young age and require repeated imaging. Between seven and eleven percent of patients with IBD are exposed to high cumulative effective radiation doses (CEDs) (>35–75 mSv), mostly patients with Crohn’s disease (Newnham E 2007, Levi Z 2009, Hou JK 2014, Estay C 2015). This is primarily due to the more widespread and repeated use of CT, which accounts for 77% of radiation dose exposure amongst patients with Crohn’s disease (Desmond et al., 2008). Reports of the projected cancer risks from the increasing CT use (Berrington et al., 2007) have led to increased patient awareness regarding the potential health risks from ionizing radiation (Coakley et al., 2011). Our responsibilities as physicians caring for these patients include education regarding radiation risk and, when an investigation that utilizes ionizing radiation is required, to keep radiation doses as low as reasonably achievable: the “ALARA” principle. Recent advances in CT technology have facilitated substantial radiation dose reductions in many clinical settings, and several studies have demonstrated significantly decreased radiation doses in Crohn’s disease patients while maintaining diagnostic image quality. However, there is a balance to be struck between reducing radiation exposure and maintaining satisfactory image quality; if radiation dose is reduced excessively, the resulting CT images can be of poor quality and may be nondiagnostic. In this paper, we summarize the available evidence related to imaging of Crohn’s disease, radiation exposure, and risk, and we report recent advances in low-dose CT technology that have particular relevance.


Author(s):  
V. Chumak ◽  
◽  
N. Petrenko ◽  
O. Bakhanova ◽  
V. Voloskyi ◽  
...  

In the dosimetry of ionizing radiation, the phantoms of the human body, which are used as a replacement for the human body in physical measurements and calculations, play an important, but sometimes underestimated, role. There are physical phantoms used directly for measurements, and mathematical phantoms for computational dosimetry. Their complexity varies from simple geometry applied for calibration purposes up to very complex, which simulates in detail the shapes of organs and tissues of the human body. The use of physical anthropomorphic phantoms makes it possible to effectively optimize radiation doses by adjusting the parameters of CT-scanning (computed tomography) in accordance with the characteristics of the patient without compromising image quality. The use of phantoms is an indispensable approach to estimate the actual doses to the organs or to determine the effective dose of workers – values that are regulated, but cannot be directly measured. The article contains an overview of types, designs and the fields of application of anthropomorphic heterogeneous physical phantoms of a human with special emphasis on their use for validation of models and methods of computational dosimetry. Key words: dose, ionizing radiation, physical, mathematical phantoms, computational dosimetry.


1984 ◽  
Vol 23 (02) ◽  
pp. 87-91 ◽  
Author(s):  
K. Flemming

SummaryIn the beginning of medical radiology, only the benefit of ionizing radiation was obvious, and radiation was handled and applied generously. After late effects had become known, the radiation exposure was reduced to doses following which no such effects were found. Thus, it was assumed that one could obtain an optimal medical benefit without inducing any hazard. Later, due to experimental findings, hypotheses arose (linear dose-effect response, no time factor) which led to the opinion that even low and lowest radiation doses were relevant for the induction of late effects. A radiation fear grew, which was unintentionally strengthened by radiation protection decrees: even for low doses a radiation risk could be calculated. Therefore, it was believed that there could still exist a radiation hazard, and the radiation benefit remained in question. If, however, all presently known facts are considered, one must conclude that large radiation doses are hazardous and low doses are inefficient, whereas lowest doses have a biopositive effect. Ionizing radiation, therefore, may cause both, hazard as well as benefit. Which of the two effects prevails is determined by the level of dose.


2020 ◽  
Vol 3 ◽  
pp. 36-39
Author(s):  
Samson O. Paulinus ◽  
Benjamin E. Udoh ◽  
Bassey E. Archibong ◽  
Akpama E. Egong ◽  
Akwa E. Erim ◽  
...  

Objective: Physicians who often request for computed tomography (CT) scan examinations are expected to have sound knowledge of radiation exposure (risks) to patients in line with the basic radiation protection principles according to the International Commission on Radiological Protection (ICRP), the Protection of Persons Undergoing Medical Exposure or Treatment (POPUMET), and the Ionizing Radiation (Medical Exposure) Regulations (IR(ME)R). The aim is to assess the level of requesting physicians’ knowledge of ionizing radiation from CT scan examinations in two Nigerian tertiary hospitals. Materials and Methods: An 18-item-based questionnaire was distributed to 141 practicing medical doctors, excluding radiologists with work experience from 0 to >16 years in two major teaching hospitals in Nigeria with a return rate of 69%, using a voluntary sampling technique. Results: The results showed that 25% of the respondents identified CT thorax, abdomen, and pelvis examination as having the highest radiation risk, while 22% said that it was a conventional chest X-ray. Furthermore, 14% concluded that CT head had the highest risk while 9% gave their answer to be conventional abdominal X-ray. In addition, 17% inferred that magnetic resonance imaging had the highest radiation risk while 11% had no idea. Furthermore, 25.5% of the respondents have had training on ionizing radiation from CT scan examinations while 74.5% had no training. Majority (90%) of the respondents were not aware of the ICRP guidelines for requesting investigations with very little (<3%) or no knowledge (0%) on the POPUMET and the IR(ME)R respectively. Conclusion: There is low level of knowledge of ionizing radiation from CT scan examinations among requesting physicians in the study locations.


2019 ◽  
Author(s):  
Bashayer Hassan Shuaib ◽  
Rahaf Hisham Niazi ◽  
Ahmed Haitham Abduljabbar ◽  
Mohammed Abdulraheem Wazzan

BACKGROUND Radiology now plays a major role to diagnose, monitoring, and management of several diseases; numerous diagnostic and interventional radiology procedures involve exposure to ionizing radiation. Radiology now plays a major role to diagnose, monitoring, and management of several diseases; numerous diagnostic and interventional radiology procedures involve exposure to ionizing radiation. OBJECTIVE This study aimed to discover and compare the awareness level of radiation doses, protection issues, and risks among radiology staff in Jeddah hospitals. METHODS A cross-sectional survey containing 25 questions on personal information and various aspects of radiation exposure doses and risks was designed using an online survey tool and the link was emailed to all radiology staff in eight tertiary hospitals in Jeddah. The authors were excluded from the study. A P-value of < .05 was used to identify statistical significance. All analyses were performed using SPSS, version 21. RESULTS Out of 156 participants the majority 151 (96.8%) had poor knowledge score, where the mean scores were 2.4±1.3 for doses knowledge, 2.1±1.1for cancer risks knowledge, 2.3±0.6 for general information, and 6.7±1.9 for the total score. Only 34.6% of the participants were aware of the dosage of a single-view chest x-ray, and 9.0% chose the right answer for the approximate effective dose received by a patient in a two-view. 42.9% were able to know the correct dose of CT abdomen single phase. There is a significant underestimation of cancer risk of CT studies especially for CT abdomen where only 23.7% knew the right risk. A p-value of <0.05 was used to identify statistical significance. No significant difference of knowledge score was detected regarding gender (P =.2) or work position (P=.66). CONCLUSIONS Our survey results show considerable inadequate knowledge in all groups without exception. We recommended a conscientious effort to deliver more solid education and obtain more knowledge in these matters and providing periodic training courses to teach how to minimize the dose of radiation and to avoid risk related. CLINICALTRIAL not applicable


2021 ◽  
pp. 105566562110017
Author(s):  
Yoshikazu Kobayashi ◽  
Masanao Kobayashi ◽  
Daisuke Kanamori ◽  
Naoko Fujii ◽  
Yumi Kataoka ◽  
...  

Objective: Some patients with cleft palate (CP) need secondary surgery to improve functionality. Although 4-dimensional assessment of velopharyngeal closure function (VPF) in patients with CP using computed tomography (CT) has been existed, the knowledge about quantitative evaluation and radiation exposure dose is limited. We performed a qualitative and quantitative assessment of VPF using CT and estimated the exposure doses. Design: Cross-sectional. Setting: Computed tomography images from 5 preoperative patients with submucous CP (SMCP) and 10 postoperative patients with a history of CP (8 boys and 7 girls, aged 4-7 years) were evaluated. Patients: Five patients had undergone primary surgery for SMCP; 10 received secondary surgery for hypernasality. Main Outcome Measures: The presence of velopharyngeal insufficiency (VPI), patterns of velopharyngeal closure (VPC), and cross-sectional area (CSA) of VPI was evaluated via CT findings. Organ-absorbed radiation doses were estimated in 5 of 15 patients. The differences between cleft type and VPI, VPC patterns, and CSA of VPI were evaluated. Results: All patients had VPI. The VPC patterns (SMCP/CP) were evaluated as coronal (1/4), sagittal (0/1), circular (1/2), and circular with Passavant’s ridge (2/2); 2 patients (1/1) were unevaluable because of poor VPF. The CSA of VPI was statistically larger in the SMCP group ( P = .0027). The organ-absorbed radiation doses were relatively lower than those previously reported. Conclusions: Four-dimensional CT can provide the detailed findings of VPF that are not possible with conventional CT, and the exposure dose was considered medically acceptable.


Author(s):  
Lucas Sousa Macedo ◽  
Renato Polese Rusig ◽  
Gustavo Bersani Silva ◽  
Alvaro Baik Cho ◽  
Teng Hsiang Wei ◽  
...  

BACKGROUND: Microsurgical flaps are widely used to treat complex traumatic wounds of upper and lower limbs. Few studies have evaluated whether the vascular changes in preoperative computed tomography angiography (CTA) influence the selection of recipient vessel and type of anastomosis and the microsurgical flaps outcomes including complications. OBJECTIVE: The aim of this study was to evaluate if preoperative CTA reduces the occurrence of major complications (revision of the anastomosis, partial or total flap failure, and amputation) of the flaps in upper and lower limb trauma, and to describe and analyze the vascular lesions of the group with CTA and its relationship with complications. METHODS: A retrospective cohort study was undertaken with all 121 consecutive patients submitted to microsurgical flaps for traumatic lower and upper limb, from 2014 to 2020. Patients were divided into two groups: patients with preoperative CTA (CTA+) and patients not submitted to CTA (CTA–). The presence of postoperative complications was assessed and, within CTA+, we also analyzed the number of patent arteries on CTA and described the arterial lesions. RESULTS: Of the 121 flaps evaluated (84 in the lower limb and 37 in the upper limb), 64 patients underwent preoperative CTA. In the CTA+ group, 56% of patients with free flaps for lower limb had complete occlusion of one artery. CTA+ patients had a higher rate of complications (p = 0.031), which may represent a selection bias as the most complex limb injuries and may have CTA indicated more frequently. The highest rate of complications was observed in chronic cases (p = 0.034). There was no statistically significant difference in complications in patients with preoperative vascular injury or the number of patent arteries. CONCLUSIONS: CTA should not be performed routinely, however, CTA may help in surgical planning, especially in complex cases of high-energy and chronic cases, since it provides information on the best recipient artery and the adequate level to perform the microanastomosis, outside the lesion area.


Sign in / Sign up

Export Citation Format

Share Document