A novel technique for the reduction of pesticide residues by a combination of low-intensity electrical current and ultrasound applications: A study on lettuce samples

2021 ◽  
Vol 354 ◽  
pp. 129360
Author(s):  
Mehmet Fatih Cengiz ◽  
Onur Basançelebi ◽  
Mehmet Başlar ◽  
Muharrem Certel
2018 ◽  
Vol 267 ◽  
pp. 60-66 ◽  
Author(s):  
Mehmet Fatih Cengiz ◽  
Mehmet Başlar ◽  
Onur Basançelebi ◽  
Mahmut Kılıçlı

2007 ◽  
Vol 73 (4) ◽  
pp. 410-413 ◽  
Author(s):  
George M. Filippakis ◽  
Manolis Leandros ◽  
Kostas Albanopoulos ◽  
Michael Genetzakis ◽  
Emmanuel Lagoudianakis ◽  
...  

Bleeding originating from the presacral venous plexus during pelvic operations is difficult to control, constituting a potentially life-threatening complication. Although suture ligatures, packing, and placement of tacks are established hemostatic techniques, they are often proved to be ineffective. We report a simple novel technique using spray diathermy for managing this severe complication. We have applied our method in four patients, two undergoing low anterior resection, and the others undergoing abdominoperineal resection for rectal cancer, that manifested severe presacral bleeding during rectal mobilization. Electrocautery at spray setting was applied slightly above the target bleeders at the presacral fascia, delivering a high-frequency electrical current in combination with drainage suction. In all cases, the method resulted in successful hemostasis. Applying spray electrocautery is a simple and effective method for controlling pre-sacral bleeding. The advantages of using such a method instead of conventional hemostatic techniques include the option of varying the degree of haemostatic effect by altering the frequency and the volume of electric current.


Agrikultura ◽  
2019 ◽  
Vol 29 (3) ◽  
pp. 124
Author(s):  
Asep Kurnia ◽  
Eman Sulaeman ◽  
Asep Nugraha Ardiwinata

ABSTRACTVerification of digital multimeter for rapid detection of insecticide residues on vegetablesThe instruments that usually used for detection of pesticide residues are Gas Chromatography (GC), High Performance Liquid Chromatography (HPLC), and Thin Layer Chromatography (TLC), however, these instruments are expensive, take time, and need a large number of chemicals. Therefore, it is needed to develop rapid method in analyzing pesticide residues. One instrument that is potential for rapid detection of pesticide residues is digital multimeter. This method uses resistance differences of electrical current on chemical compounds. The aim of this research was to assess capability of digital multimeter for rapid detection of insecticide residues on vegetables by the aspects of precision, accuracy, linearity, and detection limit. The research was conducted in IAERI laboratory, Laladon, Bogor on January to December 2012. Insecticide residues that detected were organochlorine and organophosphate on some vegetables of potato, cabbage, carrot, onion, chili, and cucumber. The results showed that precision values of digital multimeter for detection organochlorine and organophosphate residues on vegetables were 0.02 to 2.46%. Linearity values of digital multimeter for detection endrin on onion and potato, heptachlor on onion, BHC on cucumber, chlorphyriphos on potato and cabbage, and dichlorvos on cabbage were 0.81, 0.84, 0.95, 0.71, 0.95, 0.80 and 0.76, respectively. Accuracy values of digital multimeter for detecting endrin and dieldrin on onion, chlorphyriphos on potato and cabbage, and profenophos on chili were 106.93%, 115.08%, 72.89%, 72.40%, and 98.06%, respectively. Detection and quantification limits of digital multimeter for detecting organochlorine were 0.08 to 0.17 ppm and 0.27 to 0.56 ppm, respectively. Meanwhile, detection and quantification limits of digital multimeter for detecting organophosphate were 0.05 to 0.27 ppm and 0.16 to 0.90 ppm, respectively. This result showed that digital multimeter was accurate and representative instrument for detecting pesticide residues on vegetables.Keywords: Digital Multimeter, Pesticides residue, VegetablesABSTRAKAlat yang digunakan untuk analisis residu pestisida antara lain Kromatografi Gas (KG), Kromatografi Cair Kinerja Tinggi (KCKT), Kromatografi Lapis Tipis (KLT), namun alat tersebut sangat mahal, dan perlu proses cukup lama serta memerlukan bahan kimia yang banyak. Untuk itu perlu dikembangkan metode cepat analisis residu pestisida. Salah satu alternatif deteksi cepat residu pestisida adalah dengan menggunakan Alat Multimeter Digital (AMD). Teknik analisis ini menggunakan prinsip perbedaan resistensi (tahanan) terhadap arus listrik dari senyawa kimia residu pestisida. Percobaan ini bertujuan mengetahui cara kerja awal AMD untuk deteksi cepat residu insektisida pada tanaman sayuran dari aspek presisi, akurasi, linearitas, dan limit deteksi. Penelitian dilaksanakan di Laboratorium Balai Penelitian Lingkungan Pertanian (Balingtan) di Laladon Bogor, mulai bulan Januari hingga Desember 2012. Residu insektisida yang dideteksi adalah organoklorin dan organofosfat pada beberapa sayuran yaitu kentang, kubis, wortel, bawang merah, cabe merah dan mentimun. Hasil penelitian menunjukkan bahwa nilai presisi AMD dalam mendeteksi organoklorin dan organofosfat pada sayuran berkisar 0,02-2,46%. Nilai linearitas AMD dalam mendeteksi endrin pada bawang merah dan kentang, heptaklor pada bawang merah, BHC pada mentimun, klorpirifos pada kentang dan kubis, serta diklorfos pada kubis masing-masing sebesar 0,81, 0,84, 0,95, 0,71, 0,95, 0,80 dan 0,76. Nilai akurasi AMD dalam mendeteksi endrin dan dieldrin pada bawang merah, klorpirifos padakentang dan kubis, serta profenofos pada cabe merah masing-masing sebesar 106,93 %, 115,08%, 72,89 %, 72,40%, dan 98,06%. Nilai LOD (limit deteksi) dan LOQ (limit quantifikasi) AMD terhadap organoklorin berkisar antara 0,08-0,17 ppm dan 0,27-0,56 ppm, sedangkan terhadap golongan organofosfat berkisar antara 0,05-0,27 ppm dan 0,16-0,90 ppm. Hasil penelitian ini menunjukkan bahwa AMD merupakan alat yang cukup akurat dan representatif untuk deteksi cepat residu pestisida pada sayuran.Kata Kunci: Alat Multimeter Digital, Residu pestisida, Sayuran


2021 ◽  
Vol 40 (1) ◽  
Author(s):  
Emerson Roberto Santos ◽  
Maurício Vicente Tavares ◽  
Antonio Celso Duarte ◽  
Hélio Akira Furuya

This exploratory study was carried out with the objective to know the optical behavior of light-emitting diode (LED) lamps used and the temperature reached by electronic components that compose the driver (electronic circuit situated inside the body LED lamp) responsible to convert electrical alternating current from power line to direct current to operate the LED devices. Then, two different experiments were carried out with LED lamps. In the first experiment, 131 LED lamps used were chosen randomly and bought from household appliances store (bargain market product) presenting different nominal powers, 8, 10, 12 and 15 watts. All LED lamps were polarized at the power line at 127 V and revealed different optical behaviors, such as: not turn-on; flashing light (as strobe effect); flashing light (as strobe effect) with high intensity (more intense than normal); flashing light (as strobe effect) with low intensity (less intense than normal); fast turnon and turn-off only; and turn-on with low intensity of light (less intense than normal). The hypothesis for these behaviors can be attributed by three different behaviors: in lamps not turn-on, this failure can be attributed for dark spots that are created on the surface of LED device. In these lamps, all LED devices are electrically connected in serial. When a LED is inoperative, the electrical current is interrupted for all LED devices; damage to the electronic components caused by internal high temperature confined inside the lamp body during the operation causing electrical oscillations, as observed from different behaviors from flashing light, flashing light with high intensity, flashing light with low intensity and fast turn-on and turn-off only; swelling of the electrolytic capacitors causing low energy storage and varying the electrical current flow, the electrical current for other electronic components altered the normal optical behavior of the LED lamps. In the second experiment, the temperatures of electronic components located in driver were obtained out of body lamp revealing: from 33 (lowest temperature attributed to inductor) to 52.5ºC (highest temperature attributed to electrolytic capacitor). These temperature values represent the ideal or normal condition of operation for electronic components, but, when they are operating inside the lamp body, the found temperature values increased considerably. This characteristic can be better evidenced by strong color change (caused by accumulative temperature during the elapsed days used) on the printed circuit board used in the driver.


Agrikultura ◽  
2018 ◽  
Vol 29 (3) ◽  
pp. 124
Author(s):  
Asep Kurnia ◽  
Eman Sulaeman ◽  
Asep Nugraha Ardiwinata

ABSTRACTVerification of digital multimeter for rapid detection of insecticide residues on vegetablesThe instruments that usually used for detection of pesticide residues are Gas Chromatography (GC), High Performance Liquid Chromatography (HPLC), and Thin Layer Chromatography (TLC), however, these instruments are expensive, take time, and need a large number of chemicals. Therefore, it is needed to develop rapid method in analyzing pesticide residues. One instrument that is potential for rapid detection of pesticide residues is digital multimeter. This method uses resistance differences of electrical current on chemical compounds. The aim of this research was to assess capability of digital multimeter for rapid detection of insecticide residues on vegetables by the aspects of precision, accuracy, linearity, and detection limit. The research was conducted in IAERI laboratory, Laladon, Bogor on January to December 2012. Insecticide residues that detected were organochlorine and organophosphate on some vegetables of potato, cabbage, carrot, onion, chili, and cucumber. The results showed that precision values of digital multimeter for detection organochlorine and organophosphate residues on vegetables were 0.02 to 2.46%. Linearity values of digital multimeter for detection endrin on onion and potato, heptachlor on onion, BHC on cucumber, chlorphyriphos on potato and cabbage, and dichlorvos on cabbage were 0.81, 0.84, 0.95, 0.71, 0.95, 0.80 and 0.76, respectively. Accuracy values of digital multimeter for detecting endrin and dieldrin on onion, chlorphyriphos on potato and cabbage, and profenophos on chili were 106.93%, 115.08%, 72.89%, 72.40%, and 98.06%, respectively. Detection and quantification limits of digital multimeter for detecting organochlorine were 0.08 to 0.17 ppm and 0.27 to 0.56 ppm, respectively. Meanwhile, detection and quantification limits of digital multimeter for detecting organophosphate were 0.05 to 0.27 ppm and 0.16 to 0.90 ppm, respectively. This result showed that digital multimeter was accurate and representative instrument for detecting pesticide residues on vegetables.Keywords: Digital Multimeter, Pesticides residue, VegetablesABSTRAKAlat yang digunakan untuk analisis residu pestisida antara lain Kromatografi Gas (KG), Kromatografi Cair Kinerja Tinggi (KCKT), Kromatografi Lapis Tipis (KLT), namun alat tersebut sangat mahal, dan perlu proses cukup lama serta memerlukan bahan kimia yang banyak. Untuk itu perlu dikembangkan metode cepat analisis residu pestisida. Salah satu alternatif deteksi cepat residu pestisida adalah dengan menggunakan Alat Multimeter Digital (AMD). Teknik analisis ini menggunakan prinsip perbedaan resistensi (tahanan) terhadap arus listrik dari senyawa kimia residu pestisida. Percobaan ini bertujuan mengetahui cara kerja awal AMD untuk deteksi cepat residu insektisida pada tanaman sayuran dari aspek presisi, akurasi, linearitas, dan limit deteksi. Penelitian dilaksanakan di Laboratorium Balai Penelitian Lingkungan Pertanian (Balingtan) di Laladon Bogor, mulai bulan Januari hingga Desember 2012. Residu insektisida yang dideteksi adalah organoklorin dan organofosfat pada beberapa sayuran yaitu kentang, kubis, wortel, bawang merah, cabe merah dan mentimun. Hasil penelitian menunjukkan bahwa nilai presisi AMD dalam mendeteksi organoklorin dan organofosfat pada sayuran berkisar 0,02-2,46%. Nilai linearitas AMD dalam mendeteksi endrin pada bawang merah dan kentang, heptaklor pada bawang merah, BHC pada mentimun, klorpirifos pada kentang dan kubis, serta diklorfos pada kubis masing-masing sebesar 0,81, 0,84, 0,95, 0,71, 0,95, 0,80 dan 0,76. Nilai akurasi AMD dalam mendeteksi endrin dan dieldrin pada bawang merah, klorpirifos pada kentang dan kubis, serta profenofos pada cabe merah masing-masing sebesar 106,93 %, 115,08%, 72,89 %, 72,40%, dan 98,06%. Nilai LOD (limit deteksi) dan LOQ (limit quantifikasi) AMD terhadap organoklorin berkisar antara 0,08-0,17 ppm dan 0,27-0,56 ppm, sedangkan terhadap golongan organofosfat berkisar antara 0,05-0,27 ppm dan 0,16-0,90 ppm. Hasil penelitian ini menunjukkan bahwa AMD merupakan alat yang cukup akurat dan representatif untuk deteksi cepat residu pestisida pada sayuran.Kata Kunci: Alat Multimeter Digital, Residu pestisida, Sayuran


Author(s):  
Chia-Yen Lee ◽  
Zgen-Hui Chen ◽  
Chih-Yung Wen

A novel technique for the fabrication of electromagnetic micro actuators was proposed and a prototype was designed and fabricated in this study. The constituent parts of the designed actuator are comprised of the diaphragm, the micro coils, and the magnet. When an electrical current was applied to the micro coils, the magnetic force between the magnet and the coil is produced, causes the diaphragm to deflect and becomes the source of actuation. The fabrication process of the actuator combines Optical Lithography, Electron Beam Evaporation, and Electroplating. The structure of the actuating device uses PDMS as the vibrating diaphragm and electroplated copper as the coils. The diaphragm deflection can be regulated by varying the electrical current passed through the micro coil and hence the actuating effects can be controlled. The experimental results show that the maximum diaphragm deflection within elastic limits is 150 μm at an electrical current of 0.6 A for a micro coil of 100 μm line width. The micro electromagnetic actuator proposed in this study is easily fabricated and is readily integrated with Lab-on-a-Chip systems due to its planar structure.


Algorithms ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 41
Author(s):  
Oleg K. Karaduta ◽  
Aleksei F. Deon ◽  
Yulian A. Menyaev

Photomatrix therapeutic systems (PMTS) are widely used for the tasks of preventive, stimulating and rehabilitation medicine. They consist of low-intensity light-emitting diodes (LEDs) having the quasi-monochromatic irradiation properties. Depending on the LED matrix structures, PMTS are intended to be used for local and large areas of bio-objects. However, in the case of non-uniform irradiation of biological tissues, there is a risk of an inadequate physiological response to this type of exposure. The proposed approach considers a novel technique for designing this type of biomedical technical systems, which use the capabilities of stochastic algorithms for LED switching. As a result, the use of stochastic photomatrix systems based on the technology of uniform twisting generation of random variables significantly expands the possibilities of their medical application.


Author(s):  
Guilherme Botega Torsoni ◽  
Gustavo Quereza Freitas ◽  
Claudio Luis Carvalho

Electrical characterization of superconductor materials exposed to external magnetic field play a important role for many technological applications. In this paper, the electrical characterization of Bi-2223 pellet prepared by conventional route was performed. The electrical resistance temperaturedependence (RxT), showed a superconductor transition at around 105 K. The current-voltage (I-V) behavior under magnetic field and temperature has been investigated, the results point to a powerlaw dependence between the electrical current (I) and applied voltage (V), at different conditions, as described by the literature. The external DC magnetic field, was produced by a simple home-made apparatus, where a simple copper coil was used to produce an external DC magnetic field between 2,0 mT and 8,0 mT. Then, the dependence of the critical current (Ic) on magnetic field and temperature has been studied, revealing a double step behavior DOI:http://dx.doi.org/10.30609/JETI.2018-2.5682


Sign in / Sign up

Export Citation Format

Share Document