Quantification of multiple soil trace elements by combining portable X-ray fluorescence and reflectance spectroscopy

Geoderma ◽  
2022 ◽  
Vol 409 ◽  
pp. 115649
Author(s):  
G. Shrestha ◽  
R. Calvelo-Pereira ◽  
P. Roudier ◽  
A.P. Martin ◽  
R.E. Turnbull ◽  
...  
Author(s):  
O.T. Woo ◽  
G.J.C. Carpenter

To study the influence of trace elements on the corrosion and hydrogen ingress in Zr-2.5 Nb pressure tube material, buttons of this alloy containing up to 0.83 at% Fe were made by arc-melting. The buttons were then annealed at 973 K for three days, furnace cooled, followed by ≈80% cold-rolling. The microstructure of cold-worked Zr-2.5 at% Nb-0.83 at% Fe (Fig. 1) contained both β-Zr and intermetallic precipitates in the α-Zr grains. The particles were 0.1 to 0.7 μm in size, with shapes ranging from spherical to ellipsoidal and often contained faults. β-Zr appeared either roughly spherical or as irregular elongated patches, often extending to several micrometres.The composition of the intermetallic particles seen in Fig. 1 was determined using Van Cappellen’s extrapolation technique for energy dispersive X-ray analysis of thin metal foils. The method was employed to avoid corrections for absorption and fluorescence via the Cliff-Lorimer equation: CA/CB = kAB · IA/IB, where CA and CB are the concentrations by weight of the elements A and B, and IA and IB are the X-ray intensities; kAB is a proportionality factor.


Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


2018 ◽  
Author(s):  
Zoltán Kis ◽  
Katalin Gméling ◽  
Tímea Kocsis ◽  
János Osán ◽  
Mihály András Pocsai ◽  
...  

We present precise analysis of major and trace elements of the humic acid. We used three different element analytical techniques in our investigations as prompt-gamma activation analysis (PGAA), neutron activation analysis (NAA) and X-ray fluorescence (XRF) analysis was carried out. We identified 42 elements in our sample.


2020 ◽  
Author(s):  
E. V. Kochergina ◽  
A. O. Vagina ◽  
A. O. Taukin ◽  
A. V. Abramov ◽  
G. M. Bunkov ◽  
...  

2004 ◽  
Vol 14 (03n04) ◽  
pp. 133-139 ◽  
Author(s):  
T. R. RAUTRAY ◽  
V. VIJAYAN ◽  
P. K. NAYAK ◽  
S. JENA

Coins are important archaeological objects that can provide useful information regarding preparation methodology and provenance. Their classification plays a fundamental role in dating historical events, in constructing trade routes and in establishing the welfare of population. Several Indian copper coins of different periods have been studied using Energy Dispersive X-ray Fluorescence (EDXRF) spectroscopic technique. The method is rapid, efficient, multi elemental and non-destructive in nature. Concentrations of the major and trace elements like Ca , Ti , V , Cr , Mn , Fe , Co , Ni , Cu , Zn , As and Pb have been estimated in these copper coins. In the present investigation, an attempt has been made to characterize some Indian copper coins of different periods using EDXRF technique.