Behavior of octagonal concrete-filled double-skin steel tube stub columns under axial compression

2020 ◽  
Vol 170 ◽  
pp. 106115
Author(s):  
Shagea Alqawzai ◽  
Kang Chen ◽  
Le Shen ◽  
Miao Ding ◽  
Bo Yang ◽  
...  
Crystals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 1434
Author(s):  
Muhammmad Faisal Javed ◽  
Haris Rafiq ◽  
Mohsin Ali Khan ◽  
Fahid Aslam ◽  
Muhammad Ali Musarat ◽  
...  

This experimental study presents concrete-filled double-skin tubular columns and demonstrates their expected advantages. These columns consist of an outer steel tube, an inner steel tube, and concrete sandwiched between two tubes. The influence of the outer-to-inner tube dimension ratio, outer tube to thickness ratio, and type of inner tube material (steel, PVC pipe) on the ultimate axial capacity of concrete-filled double-skin tubular columns is studied. It is found that the yield strength of the inner tube does not significantly affect the ultimate axial capacity of concrete-filled double-skin tubular composites. With the replacement of the inner tube of steel with a PVC pipe, on average, less than 10% strength is reduced, irrespective of size and dimensions of the steel tube. Hence, the cost of a project can be reduced by replacing inner steel tubes with a PVC pipes. Finally, the experimental results are compared with the existing design methods presented in AISC 360-16 (2016), GB51367 (2019), and EC4 (2004). It is found from the comparison that GB51367 (2019) gives better results, followed by AISC (2016) and EC4 (2004).


2018 ◽  
Vol 11 (5) ◽  
pp. 144-152
Author(s):  
Hua Luo ◽  
◽  
Weiwei Wang ◽  
Guanghui Wang ◽  
Bo Pang ◽  
...  

2020 ◽  
Vol 146 ◽  
pp. 106483 ◽  
Author(s):  
Hongyuan Tang ◽  
Junlong Chen ◽  
Luyao Fan ◽  
Xujie Sun ◽  
Chunmei Peng

2021 ◽  
Vol 2021 ◽  
pp. 1-18
Author(s):  
Jing Ji ◽  
Maomao Yang ◽  
Zhichao Xu ◽  
Liangqin Jiang ◽  
Huayu Song

The behavior of H-shaped honeycombed stub columns with rectangular concrete-filled steel tube flanges (STHCCs) subjected to axial load was investigated experimentally. A total of 16 specimens were studied, and the main parameters varied in the tests included the confinement effect coefficient of the steel tube (ξ), the concrete cubic compressive strength (fcu), the steel web thickness (t2), and the slenderness ratio of specimens (λs). Failure modes, load-displacement curves, load-strain curves of the steel tube flanges and webs, and force mechanisms were obtained by means of axial compression tests. The parameter influences on the axial compression bearing capacity and ductility were then analyzed. The results showed that rudder slip diagonal lines occur on the steel tube outer surface and the concrete-filled steel tube flanges of all specimens exhibit shear failure. Specimen load-displacement curves can be broadly divided into elastic deformation, elastic-plastic deformation, and load descending and residual deformation stages. The specimen axial compression bearing capacity and ductility increase with increasing ξ, and the axial compression bearing capacity increases gradually with increasing fcu, whereas the ductility decreases. The ductility significantly improves with increasing t2, whereas the axial compression bearing capacity increases slightly. The axial compression bearing capacity decreases gradually with increasing λs, whereas the ductility increases. An analytical expression for the STHCC short column axial compression bearing capacity is established by introducing a correction function ( w ), which has good agreement with experimental results. Finally, several design guidelines are suggested, which can provide a foundation for the popularization and application of this kind of novel composite column in practical engineering projects.


2019 ◽  
Vol 19 (06) ◽  
pp. 1950063 ◽  
Author(s):  
Kang He ◽  
Yu Chen

This paper studies the structural stability of circular steel tubular stub columns at elevated temperatures under axial compression. Fifty-one specimens are subjected to high-temperature treatment and axial compression. The variables of the specimen are temperature, wall thickness of steel tube and duration of high temperature. The displacement–load curve, strain–load curve, ultimate load, axial compressive stiffness and failure characteristics of the specimens were analyzed. Test results show that after exposure to high temperatures, the specimens’ failure phenomenon in the axial compression loading test is consistent with that at room temperature, the bearing capacity decreases considerably, the ductility decreases slightly and the axial compressive stiffness changes irregularly. Temperature is the determining factor of the ultimate load of the specimen, and the reducing extent of ultimate load increases with the temperature. When the temperature reaches 1000∘C, its maximum reducing extent exceeds 50%. Among the three parameters considered in this study, the duration of high temperature has the least influence on the specimen.


2014 ◽  
Vol 17 (4) ◽  
pp. 431-452 ◽  
Author(s):  
Jun Wang ◽  
Weiqing Liu ◽  
Ding Zhou ◽  
Lu Zhu ◽  
Hai Fang

2013 ◽  
Vol 838-841 ◽  
pp. 439-443 ◽  
Author(s):  
Zhi Liang Zuo ◽  
Da Xin Liu ◽  
Jian Cai ◽  
Chun Yang ◽  
Qing Jun Chen

To improve the mechanical behavior of T-shaped concrete-filled steel tubular (T-CFT) column, the method that setting binding bars along the height of steel tube is proposed. Five T-CFT stub columns with binding bars and another two without binding bars subjected to axial compression were tested. The influences of the spacing and diameter of binding bars on the failure modes, maximum strength, and ductility of T-CFT stub columns are investigated. The experimental results demonstrate that by setting binding bars or decreasing the spacing of binding bars, the buckling modes of the steel plates are changed, the local buckling of the steel plates is postponed, and the confinement effects on the core concrete can be improved significantly. By setting binding bars, the bearing capacity and ductility of the columns are enhanced by 1.17 and 3.38 times at most, respectively. By increasing the diameter of binding bars, the ductility of the columns is improved, but the bearing capacity and buckling strength cannot be improved when the diameter is large enough.


2015 ◽  
Vol 1119 ◽  
pp. 688-693 ◽  
Author(s):  
Butje Alfonsius Louk Fanggi ◽  
Togay Ozbakkloglu

FRP-concrete-steel double-skin tubular columns (DSTCs) are a new form composite column system that effectively combines the advantages of the constituent materials. The performance of this column system has been experimentally investigated in a number of recent studies. However, apart from a single study reported on square DSTCs, all of the existing studies have been concerned with DSTCs with circular external tubes. This paper reports on part of an ongoing experimental program at the University of Adelaide on FRP-concrete-steel composite columns. The results from 12 square hollow and concrete-filled DSTCs and six companion hollow concrete-filled FRP tubes (H-CFFTs) that were tested under axial compression are presented. Results of the experimental study indicate that hollow DSTCs with larger inner steel tube diameters develop similar ultimate axial stresses to but significantly larger axial strains than companion DSTCs with smaller inner steel tubes. The results also show that, in concrete-filled DSTCs with similar Ds/ts ratios, an increase in the steel tube diameter leads to an increase in both axial stress and strain of concrete. It was observed that H-CFFTs perform significantly worse than both hollow and filled DSTCs under axial compression, and their behavior further degrades with an increase in the diameter of their inner voids.


2012 ◽  
Vol 166-169 ◽  
pp. 859-862 ◽  
Author(s):  
Yong Jin Li ◽  
Qing Xin Ren ◽  
Fei Yu Liao

Concrete filled steel tube (CFST) reinforced concrete (CFSTRC) columns subjected to axial compression were experimentally investigated in this paper. A total of ten specimens were tested. The main parameters varied in the experiments were steel tube ratio and concrete strength. It was found that, under axial compression, the column ultimate strength increases with the increasing of steel tube ratio and concrete strength. The work in this paper provides a basis for the further theoretical study on the behavior of CFSTRC columns.


Sign in / Sign up

Export Citation Format

Share Document