Effects of two non-invasive continuous positive pressure devices on the acoustic environment of preterm infants

2020 ◽  
Vol 26 (3) ◽  
pp. 167-170
Author(s):  
Celine Richard ◽  
Ellyn Hamm ◽  
Lelia Emery ◽  
Arnaud Jeanvoine ◽  
Melissa Moore-Clingenpeel ◽  
...  
Trials ◽  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Francesco Cresi ◽  
Federica Chiale ◽  
Elena Maggiora ◽  
Silvia Maria Borgione ◽  
Mattia Ferroglio ◽  
...  

Abstract Background Non-invasive ventilation (NIV) has been recommended as the best respiratory support for preterm infants with respiratory distress syndrome (RDS). However, the best NIV technique to be used as first intention in RDS management has not yet been established. Nasal intermittent positive pressure ventilation (NIPPV) may be synchronized (SNIPPV) or non-synchronized to the infant’s breathing efforts. The aim of the study is to evaluate the short-term effects of SNIPPV vs. NIPPV on the cardiorespiratory events, trying to identify the best ventilation modality for preterm infants at their first approach to NIV ventilation support. Methods An unmasked randomized crossover study with three treatment phases was designed. All newborn infants < 32 weeks of gestational age with RDS needing NIV ventilation as first intention or after extubation will be consecutively enrolled in the study and randomized to the NIPPV or SNIPPV arm. After stabilization, enrolled patients will be alternatively ventilated with two different techniques for two time frames of 4 h each. NIPPV and SNIPPV will be administered with the same ventilator and the same interface, maintaining continuous assisted ventilation without patient discomfort. During the whole duration of the study, the patient’s cardiorespiratory data and data from the ventilator will be simultaneously recorded using a polygraph connected to a computer. The primary outcome is the frequency of episodes of oxygen desaturation. Secondary outcomes are the number of the cardiorespiratory events, FiO2 necessity, newborn pain score evaluation, synchronization index, and thoracoabdominal asynchrony. The calculated sample size was of 30 patients. Discussion It is known that NIPPV produces a percentage of ineffective acts due to asynchronies between the ventilator and the infant’s breaths. On the other hand, an ineffective synchronization could increase work of breathing. Our hypothesis is that an efficient synchronization could reduce the respiratory work and increase the volume per minute exchanged without interfering with the natural respiratory rhythm of the patient with RDS. The results of this study will allow us to evaluate the effectiveness of the synchronization, demonstrating whether SNIPPV is the most effective non-invasive ventilation mode in preterm infants with RDS at their first approach to NIV ventilation. Trial registration ClinicalTrials.gov NCT03289936. Registered on September 21, 2017.


2021 ◽  
Vol 49 (2) ◽  
pp. 030006052098491
Author(s):  
Yan Li ◽  
Qiufen Wei ◽  
Dan Zhao ◽  
Yan Mo ◽  
Liping Yao ◽  
...  

Objective To investigate the effectiveness and safety of non-invasive high-frequency oscillatory ventilation (NHFOV) in post-extubation preterm infants. Methods This was a randomized, controlled trial. A total of 149 preterm infants aged between 25 to 34 weeks’ gestational age with a birth weight of <1500 g who required invasive mechanical ventilation on admission were included. After extubation, they were randomized to the NHFOV group (n = 47), nasal intermittent positive pressure ventilation (NIPPV) group (n = 51), or nasal continuous positive airway pressure (NCPAP) group (n = 51). We compared the effectiveness and safety among these three groups. Results A total of 139 preterm infants finally completed the study. The reintubation rate was significantly lower in the NHFOV group than in the other groups. The duration of non-invasive ventilation and the length of hospital stay in the NHFOV and NIPPV groups were significantly shorter than those in the NCPAP group. The incidence of bronchopulmonary dysplasia in the NHFOV and NIPPV groups was significantly lower than that in the NCPAP group. The NHFOV group had significantly less nasal injury than the NCPAP group. Conclusion As post-extubation respiratory support in preterm infants, NHFOV has a lower reintubation rate compared with NCPAP and NIPPV, without increasing the rate of complications.


Author(s):  
Marie-Eve Rochon ◽  
Gregory Lodygensky ◽  
Laurence Tabone ◽  
Sandrine Essouri ◽  
Sylvain Morneau ◽  
...  

ObjectivesTo assess the feasibility and tolerance of NeuroPAP, a new non-invasive ventilation mode which continuously adjusts (during both inspiration and expiration) the pressure support proportionally to the diaphragm electrical activity (Edi), in preterm infants and to evaluate the impact on ventilation pressure and Edi.DesignProspective cross-over single-centre feasibility study.SettingOne level 3 neonatal intensive care unit in Canada.PatientsStable preterm infants ventilated with non-invasive positive pressure ventilation (NIPPV).InterventionsSubjects were successively ventilated in NIPPV with prestudy settings (30 min), in NeuroPAP with minimal pressure similar to NIPPV PEEP (positive end-expiratory pressure) (60 min), in NeuroPAP with minimal pressure reduced by 2 cmH20 (60 min), in continuous positive airway pressure (15 min) and again in NIPPV (30 min). Main outcome measures included tolerance, ventilation pressure, Edi and patient-ventilator synchrony.ResultsTwenty infants born at 28.0±1.0 weeks were included. NeuroPAP was well tolerated and could be delivered during 100% of planned period. During NeuroPAP, the PEEP was continuously adjusted proportionally to tonic diaphragm Edi, although the average PEEP value was similar to the set minimal pressure. During NeuroPAP, 83 (78–86)% breaths were well synchronised vs 9 (6–12)% breaths during NIPPV (p<0.001).ConclusionsNeuroPAP is feasible and well tolerated in stable preterm infants, and it allows transient adaptation in PEEP in response to tonic diaphragm electrical activity changes. Further studies are warranted to determine the impact of these findings on clinical outcomes.Trial registration numberNCT02480205.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Alaa Masry ◽  
Nuha A. M. A. Nimeri ◽  
Olfa Koobar ◽  
Samer Hammoudeh ◽  
Prem Chandra ◽  
...  

Abstract Introduction Respiratory Distress Syndrome (RDS) is a common cause of neonatal morbidity and mortality in premature newborns. In this study, we aim to compare the reintubation rate in preterm babies with RDS who were extubated to Nasal Continuous Positive Airway Pressure (NCPAP) versus those extubated to Nasal Intermittent Positive Pressure Ventilation (NIPPV). Methods This is a retrospective study conducted in the Neonatal Intensive Care Unit (NICU) of Women’s Wellness and Research Center (WWRC), Doha, Qatar. The medical files (n = 220) of ventilated preterm infants with gestational age ranging between 28 weeks 0 days and 36 weeks + 6 days gestation and extubated to non-invasive respiratory support (whether NCPAP, NIPPV, or Nasal Cannula) during the period from January 2016 to December 2017 were reviewed. Results From the study group of 220 babies, n = 97 (44%) babies were extubated to CPAP, n = 77 (35%) were extubated to NIPPV, and n = 46 (21%) babies were extubated to Nasal Cannula (NC). Out of the n = 220 babies, 18 (8.2%) were reintubated within 1 week after extubation. 14 of the 18 (77.8%) were reintubated within 48 h of extubation. Eleven babies needed reintubation after being extubated to NCPAP (11.2%) and seven were reintubated after extubation to NIPPV (9.2%), none of those who were extubated to NC required reintubation (P = 0.203). The reintubation rate was not affected by extubation to any form of non-invasive ventilation (P = 0.625). The mode of ventilation before extubation does not affect the reintubation rate (P = 0.877). The presence of PDA and NEC was strongly associated with reintubation which increased by two and four-folds respectively in those morbidities. There is an increased risk of reintubation with babies suffering from NEC and BPD and this was associated with an increased risk of hospital stay with a P-value ranging (from 0.02–0.003). Using multivariate logistic regression, NEC the NEC (OR = 5.52, 95% CI 1.26, 24.11, P = 0.023) and the vaginal delivery (OR = 0.23, 95% CI 0.07, 0.78, P = 0.018) remained significantly associated with reintubation. Conclusion Reintubation rates were less with NIPPV when compared with NCPAP, however, this difference was not statistically significant. This study highlights the need for further research studies with a larger number of neonates in different gestational ages birth weight categories. Ascertaining this information will provide valuable data for the factors that contribute to re-intubation rates and influence the decision-making and management of RDS patients in the future.


Author(s):  
Risha Bhatia ◽  
Hazel R Carlisle ◽  
Ruth K Armstrong ◽  
C Omar Farouk Kamlin ◽  
Peter G Davis ◽  
...  

ObjectiveTo evaluate the feasibility of electrical impedance tomography (EIT) to describe the regional tidal ventilation (VT) and change in end-expiratory lung volume (EELV) patterns in preterm infants during the process of extubation from invasive to non-invasive respiratory support.DesignProspective observational study.SettingSingle-centre tertiary neonatal intensive care unit.PatientsPreterm infants born <32 weeks’ gestation who were being extubated to nasal continuous positive airway pressure as per clinician discretion.InterventionsEIT measurements were taken in supine infants during elective extubation from synchronised positive pressure ventilation (SIPPV) before extubation, during and then at 2 and 20 min after commencing nasal continuous positive applied pressure (nCPAP). Extubation and pressure settings were determined by clinicians.Main outcome measuresGlobal and regional ΔEELV and ΔVT, heart rate, respiratory rate and oxygen saturation were measured throughout.ResultsThirty infants of median (range) 2 (1, 21) days were extubated to a median (range) CPAP 7 (6, 8) cm H2O. SpO2/FiO2 ratio was a mean (95% CI) 50 (35, 65) lower 20 min after nCPAP compared with SIPPV. EELV was lower at all points after extubation compared with SIPPV, and EELV loss was primarily in the ventral lung (p=0.04). VT was increased immediately after extubation, especially in the central and ventral regions of the lung, but the application of nCPAP returned VT to pre-extubation patterns.ConclusionsEIT was able to describe the complex lung conditions occurring during extubation to nCPAP, specifically lung volume loss and greater use of the dorsal lung. EIT may have a role in guiding peri-extubation respiratory support.


Sign in / Sign up

Export Citation Format

Share Document