Effect of working pressure, fluid temperature, nozzle type and nozzle orifice size, on spray characteristics using viscous feed additive DL-2-hydroxy-4-(methylthio)-butanoic-acid

2018 ◽  
Vol 336 ◽  
pp. 383-392 ◽  
Author(s):  
I. Gaytan ◽  
B. Nicolas ◽  
F. Gouriou ◽  
J.P. Leru ◽  
J. Mallarach
2015 ◽  
Vol 29 (2) ◽  
pp. 298-310 ◽  
Author(s):  
Cody F. Creech ◽  
Ryan S. Henry ◽  
Bradley K. Fritz ◽  
Greg R. Kruger

Recent concerns regarding herbicide spray drift, its subsequent effect on the surrounding environment, and herbicide efficacy have prompted applicators to focus on methods to reduce off-target movement of herbicides. Herbicide applications are complex processes, and as such, few studies have been conducted that consider multiple variables that affect the droplet spectrum of herbicide sprays. The objective of this study was to evaluate the effects of nozzle type, orifice size, herbicide active ingredient, pressure, and carrier volume on the droplet spectra of the herbicide spray. Droplet spectrum data were collected on 720 combinations of spray-application variables, which included six spray solutions (five herbicides and water alone), four carrier volumes, five nozzles, two orifice sizes, and three operating pressures. The laboratory study was conducted using a Sympatec laser diffraction instrument to determine the droplet spectrum characteristics of each treatment combination. When averaged over each main effect, nozzle type had the greatest effect on droplet size. Droplet size rankings for nozzles, ranked smallest to largest using volume median diameter (Dv0.5) values, were the XR, TT, AIXR, AI, and TTI nozzle with 176% change in Dv0.5 values from the XR to the TTI nozzle. On average, increasing the nozzle orifice size from a 11003 orifice to a 11005 increased the Dv0.5 values 8%. When compared with the water treatment, cloransulam (FirstRate) did not change the Dv0.5 value. Clethodim (Select Max), glyphosate (Roundup PowerMax), lactofen (Cobra), and glufosinate (Ignite) all reduced the Dv0.5 value 5, 11, 11, and 18%, respectively, when compared with water averaged over the other variables. Increasing the pressure of AIXR, TT, TTI, and XR nozzles from 138 to 276 kPa and the AI nozzle from 276 to 414 kPa decreased the Dv0.5 value 25%. Increasing the pressure from 276 to 414 kPa and from 414 to 552 kPa for the same nozzle group and AI nozzle decreased the Dv0.5 value 14%. Carrier volume had the least effect on the Dv0.5 value. Increasing the carrier volume from 47 to 187 L ha−1 increased the Dv0.5 value 5%, indicating that droplet size of the herbicides tested were not highly dependent on delivery volume. The effect on droplet size of the variables examined in this study from greatest effect to least effect were nozzle, operating pressure, herbicide, nozzle orifice size, and carrier volume.


2020 ◽  
Vol 57 (5) ◽  
pp. 1560-1566
Author(s):  
Junho Yoon ◽  
Huijun An ◽  
Namjin Kim ◽  
Jun-Hyung Tak

Abstract For the indoor and outdoor pest controls, various types of insecticide formulations are available including aerosols, sprays, electric vaporizers, mosquito coils, and traps. In the present study, the insecticidal activity of aerosols, the most commonly used formulation of household insecticides for mosquito control, against Aedes albopictus (Skuse) was assessed using seven commercial products and some attributes which can affect the efficacy of aerosol were investigated as well. The products had difference in their chemical composition of active ingredients, propellant/liquid phase ratios, solvent types, and nozzle orifice sizes, and these characteristics seem to affect the overall insecticidal activity. In general, solvent type dominantly determined the insecticidal activity, where four products in oil-based solvent system showed greater mortality (97.5% in average) than water-based aerosols (38.3% in average) against the mosquitoes located at the far side of the test chamber. The contribution of solvent type and nozzle orifice size were further examined with the sample aerosols, and the orifice size were determined more influential to the spray distance. Regardless of solvent types, the sample products attached to a bigger actuator (0.96 mm in diameter) showed greater knock-down activity (>98%) than the smaller ones (0.48 mm, 62.5% in average) to the back panel in the chamber. On the other hand, solvent system significantly affected the residual activity, as the oil-based and water-based aerosols showed 2.3- and 4.8-fold decrease in KT50 values, respectively, between 1 and 10 min after the spray.


2012 ◽  
Vol 58 (2) ◽  
Author(s):  
A. Hussein ◽  
M. Hafiz ◽  
H. Rashid ◽  
A. Halim ◽  
W. Wisnoe ◽  
...  

An experimental work to investigate the swirl spray characteristics that emanates from hollow–cone and solid–cone spray simplex atomizers is presented. Main objective of the research is to investigate the spray characteristics, i.e. spray breakup length, discharge coefficient and spray cone angle at different nozzle orifice diameter and injection pressure. Discharge coefficient is almost uninfluenced by the operating Reynolds number. This test also reveals that both breakup length and spray cone angle increases as orifice diameter is increased. Higher injection pressure leads to shorter breakup length and wider spray cone angle.


2019 ◽  
Vol 50 (3) ◽  
Author(s):  
M. H. R. Alheidary

The present experiment was carried out at the Dept. of Agricultural Machines and Equipment, College of Agriculture, University of Basrah.  The aim of the study is to highlight the effect of the nozzle type, working pressure and their interaction onto droplet quality using knapsack sprayer to improve their performance. Droplet characteristics were sampled on white paper cards at different distances from the nozzle. On the samples spray deposits, spray coverage, droplet size, and volume median diameter was measured using BSF tracer with water after their deposit on the sample. The main studied parameters were: Six nozzle types hollow cone, Flat fan ceramic, flat fan ISO, CFA, AirMix and flat fan air induction nozzle. Two working pressures were 15 and 25 psi. All measurements carried out at the same nozzle height of 50cm by using CRD with three replications. The main results of this study showed the best spray deposition and spray coverage with the highest values 0.06nµl.cm-2 and 63% respectively when hollow cone nozzle was compared to other nozzles under the same operating conditions.  Whereas, the Flat fan air induction nozzle appeared the most significant droplet size and VMD 377.69 µm and 378 µm respectively when it was compared to the hollow cone and flat fan nozzles.


Planta Medica ◽  
2010 ◽  
Vol 76 (12) ◽  
Author(s):  
M Walkenhorst ◽  
S Ivemeyer ◽  
J Spranger ◽  
G Arndt ◽  
R Schaette

Planta Medica ◽  
2016 ◽  
Vol 81 (S 01) ◽  
pp. S1-S381
Author(s):  
T Kaschubek ◽  
E Mayer ◽  
G Schatzmayr ◽  
K Teichmann

2019 ◽  
Vol 2019 (3) ◽  
pp. 6-11
Author(s):  
Батырхан Абилов ◽  
Batyrkhan Abilov ◽  
Лариса Пашкова ◽  
Larisa Pashkova

The article presents the data obtained as a result of carrying by employees of the Research Institute of sheep and goat breeding, a branch of the FSBSI "North Caucasus FARC", the scientific and economic experience to study the efficiency of a new fodder additive "Organic" on the productive and physiological indices of bull-calves during the completion of growing in the conditions of the farm "Pata" agricultural enterprise in the Karachay-Cherkessia Republic. The statement of the experience and all researches were carried out according to generally accepted methods. In the course of the experiment, the following indices were studied: the chemical compound of forages, the dynamics of a live weight gain in the experimental stock, hematological parameters, control slaughter data, economic indices. Completed researches have shown positive result from the use of the fodder additive "Organic" in bull-calves diets: an increase in the average daily gain of live weight by 25%, a slaughter yield by 1% and a high level of profitability – 27%. Thus, the additional introduction of "Organic" in a diet of young horned cattle in the 2nd experimental group promoted more intensive metabolism, stabilization of a physiological state, increase in productivity and, as a consequence, profitability of beef production. Researches in this direction reveal the latent fodder reserves promoting increase in the productivity of agricultural animals.


2003 ◽  
Vol 762 ◽  
Author(s):  
Guofu Hou ◽  
Xinhua Geng ◽  
Xiaodan Zhang ◽  
Ying Zhao ◽  
Junming Xue ◽  
...  

AbstractHigh rate deposition of high quality and stable hydrogenated amorphous silicon (a-Si:H) films were performed near the threshold of amorphous to microcrystalline phase transition using a very high frequency plasma enhanced chemical vapor deposition (VHF-PECVD) method. The effect of hydrogen dilution on optic-electronic and structural properties of these films was investigated by Fourier-transform infrared (FTIR) spectroscopy, Raman scattering and constant photocurrent method (CPM). Experiment showed that although the phase transition was much influenced by hydrogen dilution, it also strongly depended on substrate temperature, working pressure and plasma power. With optimized condition high quality and high stable a-Si:H films, which exhibit σph/σd of 4.4×106 and deposition rate of 28.8Å/s, have been obtained.


Sign in / Sign up

Export Citation Format

Share Document