Nanocomposite of cosubstituted carbonated hydroxyapatite fabricated inside Poly(sodium hyaluronate-acrylamide) hydrogel template prepared by gamma radiation for osteoblast cell regeneration

2021 ◽  
Vol 183 ◽  
pp. 109408 ◽  
Author(s):  
Mohamed Mohamady Ghobashy ◽  
Naeem M. El-Sawy ◽  
Ahmad S. Kodous
Author(s):  
Venita F. Allison

In 1930, Moore, Hughes and Gallager reported that after castration seminal vesicle epithelial cell atrophy occurred and that cell regeneration could be achieved with daily injections of testis extract. Electron microscopic studies have confirmed those observations and have shown that testosterone injections restore the epithelium of the seminal vesicle in adult castrated male rats. Studies concerned with the metabolism of androgens point out that dihydrotestosterone stimulates cell proliferation and that other metabolites of testosterone probably influence secretory function in certain target cells.Although the influence of androgens on adult seminal vesicle epithelial cytology is well documented, little is known of the effect of androgen depletion and replacement on those cells in aging animals. The present study is concerned with the effect of castration and testosterone injection on the epithelium of the seminal vesicle of aging rats.


Author(s):  
K. Cowden ◽  
B. Giammara ◽  
T. Devine ◽  
J. Hanker

Plaster of Paris (calcium sulfate hemihydrate, CaSO4. ½ H2O) has been used as a biomedical implant material since 1892. One of the primary limiting factors of these implants is their mechanical properties. These materials have low compressive and tensile strengths when compared to normal bone. These are important limiting factors where large biomechanical forces exist. Previous work has suggested that sterilization techniques could affect the implant’s strength. A study of plaster of Paris implant mechanical and physical properties to find optimum sterilization techniques therefore, could lead to a significant increase in their application and promise for future use as hard tissue prosthetic materials.USG Medical Grade Calcium Sulfate Hemihydrate Types A, A-1 and B, were sterilized by dry heat and by gamma radiation. Types A and B were additionally sterilized with and without the setting agent potassium sulfate (K2SO4). The plaster mixtures were then moistened with a minimum amount of water and formed into disks (.339 in. diameter x .053 in. deep) in polyethylene molds with a microspatula. After drying, the disks were fractured with a Stokes Hardness Tester. The compressive strengths of the disks were obtained directly from the hardness tester. Values for the maximum tensile strengths σo were then calculated: where (P = applied compression, D = disk diameter, and t = disk thickness). Plaster disks (types A and B) that contained no setting agent showed a significant loss in strength with either dry heat or gamma radiation sterilization. Those that contained potassium sulfate (K2SO4) did not show a significant loss in strength with either sterilization technique. In all comparisons (with and without K2SO4 and with either dry heat or gamma radiation sterilization) the type B plaster had higher compressive and tensile strengths than that of the type A plaster. The type A-1 plaster however, which is specially modified for accelerated setting, was comparable to that of type B with K2SO4 in both compressive and tensile strength (Table 1).


1994 ◽  
Vol 111 (3) ◽  
pp. 281-301 ◽  
Author(s):  
T TSUE ◽  
E OESTERLE ◽  
E RUBEL

1999 ◽  
Vol 96 (1) ◽  
pp. 143-146 ◽  
Author(s):  
J.-P. Pouget ◽  
J.-L. Ravanat ◽  
T. Douki ◽  
M.-J. Richard ◽  
J. Cadet

2020 ◽  
pp. 8-12
Author(s):  
Alexandr V. Oborin ◽  
Anna Y. Villevalde ◽  
Sergey G. Trofimchuk

The results of development of the national primary standard of air kerma, air kerma rate, exposure, exposure rate and energy flux for X-rays and gamma radiation GET 8-2011 in 2019 are presented according to the recommendations of the ICRU Report No. 90 “Key Data for Ionizing-Radiation Dosimetry: Measurement Standards and Applications”. The following changes are made to the equations for the units determination with the standard: in the field of X-rays, new correction coefficients of the free-air ionization chambers are introduced and the relative standard uncertainty of the average energy to create an ion pair in air is changed; in the field of gamma radiation, the product of the average energy to create an ion pair in air and the electron stopping-power graphite to air ratio for the cavity ionization chambers is changed. More accurate values of the units reproduced by GET 8-2019 are obtained and new metrological characteristics of the standard are stated.


1975 ◽  
Vol 116 (7) ◽  
pp. 517 ◽  
Author(s):  
O.F. Prilutskii ◽  
I.L. Rozental' ◽  
V.V. Usov
Keyword(s):  

1980 ◽  
Vol 132 (12) ◽  
pp. 700
Author(s):  
A.M. Gal'per ◽  
Yu.D. Kotov ◽  
B.I. Luchkov
Keyword(s):  

2018 ◽  
Vol 9 (08) ◽  
pp. 20193-20206 ◽  
Author(s):  
Md. Akhlak Bin Aziz ◽  
Md. Faisal Rahman ◽  
Md. Mahidul Haque Prodhan

The paper compares  Lead, Copper and Aluminium as gamma radiation shielding material using both experimental and simulation techniques. Cs- 137 (662KeV), Na-22 (511KeV) and Na- 22(1274KeV) were used as gamma radiation sources and a sodium iodide (NaI) detector was used to detect the radiation. Variations were noted for detected gamma count rates by changing shielding material thickness. In the experimental approach, thickness was varied by placing sheets of a particular test material one by one. For simulation, Monte Carlo n- Particle (MCNP) code version 4c was used and the geometry of the whole experimental setup was plotted in it. The results were then compared for each test material and it was found that lead is the best shielding material for gamma radiation followed by copper and aluminium.


Sign in / Sign up

Export Citation Format

Share Document