Angular vertical comb actuators assembled on-chip using in-plane electrothermal actuators and latching mechanisms

2011 ◽  
Vol 165 (1) ◽  
pp. 94-100 ◽  
Author(s):  
Youngkee Eun ◽  
Hyungjoo Na ◽  
Jungwook Choi ◽  
Jae-ik Lee ◽  
Jongbaeg Kim
Micromachines ◽  
2018 ◽  
Vol 9 (10) ◽  
pp. 496
Author(s):  
Kai Wu ◽  
Marcel Tichem

Photonic packaging, which includes high-precision assembly of photonic sub-systems, is currently a bottleneck in the development of commercially-available integrated photonic products. In the pursuit of a fully-automated, high-precision, and cost-effective photonic alignment scheme for two multi-channel photonic chips, this paper explores different designs of the on-chip electrothermal actuators for positioning mechanically-flexible waveguide structures. The final alignment goal is ∼100 nm waveguide to waveguide. The on-chip actuators, particularly for out-of-plane actuation, are built in a 16 μm-thick SiO 2 photonic-material stack with 5 μm-thick poly-Si as an electrothermal element. A major challenge of out-of-plane positioning is a 6 μm height difference of the waveguides to be aligned, due to different built-up material stacks, together with a misalignment tolerance of 1 μm–2 μm from the pre-assembly (flip-chip) process. Therefore, the bimorph-actuator design needs to compensate this height difference, and provide sufficient motion to align the waveguides. We propose to exploit the post-release deformation of so-called short-loop bimorph actuator designs to meet these joint demands. We explore different design variants based on the heater location and the integration of actuator beams with waveguide beams. The actuator design (with 30 μm poly-Si and 900 μm SiO 2 in length) has ∼8 μm out-of-plane deflection and is able to generate ∼4 μm motion, which meets the design goal.


Micromachines ◽  
2019 ◽  
Vol 10 (6) ◽  
pp. 407 ◽  
Author(s):  
Kuang Fang ◽  
Tengjiang Hu ◽  
Xueting Zhang ◽  
Zhiming Zhang ◽  
Xiaohuang Jiang ◽  
...  

The design and characterization of microelectromechanical systems (MEMS) based on-chip SAD (Safety and Arming Device) are proposed. An encryption system has been integrated into the device to enhance its reliability during the electromagnetic interference. The conversion between safe status and arm status is reversible due to the bidirectional actuation design of the slider and pawl on the SOI (Silicon on Insulator) chip, being driven by the chevron electrothermal actuators. The width of each tooth on the slider, which contains coding information, is different from that of its adjacent neighbor. Additionally, the different teeth width, respectively 32 μm, 82 μm, requiring different decoding displacement of 100 μm and 150 μm, corresponds to the different decoding voltage of 13.5 V and 14.8 V. The travel range of interrupter in the SAD will only be limited by the chip dimension and be able to cover the motion of ±1 mm in the present research, due to the capability of motion retention. Finally, the SAD is integrated with a copper azide exploding chip to measure the average velocity of the titanium flyer for the application feasibility validation.


2020 ◽  
Vol 477 (14) ◽  
pp. 2679-2696
Author(s):  
Riddhi Trivedi ◽  
Kalyani Barve

The intestinal microbial flora has risen to be one of the important etiological factors in the development of diseases like colorectal cancer, obesity, diabetes, inflammatory bowel disease, anxiety and Parkinson's. The emergence of the association between bacterial flora and lungs led to the discovery of the gut–lung axis. Dysbiosis of several species of colonic bacteria such as Firmicutes and Bacteroidetes and transfer of these bacteria from gut to lungs via lymphatic and systemic circulation are associated with several respiratory diseases such as lung cancer, asthma, tuberculosis, cystic fibrosis, etc. Current therapies for dysbiosis include use of probiotics, prebiotics and synbiotics to restore the balance between various species of beneficial bacteria. Various approaches like nanotechnology and microencapsulation have been explored to increase the permeability and viability of probiotics in the body. The need of the day is comprehensive study of mechanisms behind dysbiosis, translocation of microbiota from gut to lung through various channels and new technology for evaluating treatment to correct this dysbiosis which in turn can be used to manage various respiratory diseases. Microfluidics and organ on chip model are emerging technologies that can satisfy these needs. This review gives an overview of colonic commensals in lung pathology and novel systems that help in alleviating symptoms of lung diseases. We have also hypothesized new models to help in understanding bacterial pathways involved in the gut–lung axis as well as act as a futuristic approach in finding treatment of respiratory diseases caused by dysbiosis.


2016 ◽  
Vol 136 (6) ◽  
pp. 244-249
Author(s):  
Takahiro Watanabe ◽  
Fumihiro Sassa ◽  
Yoshitaka Yoshizumi ◽  
Hiroaki Suzuki

Sign in / Sign up

Export Citation Format

Share Document