Amperometric glucose biosensor based on NiFe2O4 nanoparticles and chitosan

2010 ◽  
Vol 145 (1) ◽  
pp. 293-298 ◽  
Author(s):  
Liqiang Luo ◽  
Qiuxia Li ◽  
Yanhong Xu ◽  
Yaping Ding ◽  
Xia Wang ◽  
...  
Gels ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. 272
Author(s):  
Amin Fatoni ◽  
Aziz Wijonarko ◽  
Mekar Dwi Anggraeni ◽  
Dadan Hermawan ◽  
Hartiwi Diastuti ◽  
...  

Glucose biosensors based on porous material of alginate cryogel has been developed, and the cryogel provides a large surface area for enzyme immobilization. The alginate cryogel has been supplemented with NiFe2O4 nanoparticles to improve the electron transfer for electrochemical detection. The fabrication parameters and operational conditions for the biosensor have also been optimized. The results showed that the optimum addition of NiFe2O4 nanoparticles to the alginate solution was 0.03 g/mL. The optimum operational conditions for the electrochemical detection were a cyclic voltammetry scan rate of 0.11 V/s, buffer pH of 7.0, and buffer concentration of 150 mM. The fabricated alginate NiFe2O4 nanoparticles cryogel-based glucose biosensor showed a linear response for glucose determination with a regression line of y = 18.18x + 455.28 and R² = 0.98. Furthermore, the calculated detection limit was 0.32 mM and the limit of quantification was 1.06 mM.


2011 ◽  
Vol E94-C (12) ◽  
pp. 1855-1857
Author(s):  
Huihui WANG ◽  
Hitoshi OHNUKI ◽  
Hideaki ENDO ◽  
Mitsuru IZUMI

2020 ◽  
Vol 16 (6) ◽  
pp. 744-752
Author(s):  
Kuan Luo ◽  
Xinyu Jiang

Background: Diabetes Mellitus (DM) is a major public metabolic disease that influences 366 million people in the world in 2011, and this number is predicted to rise to 552 million in 2030. DM is clinically diagnosed by a fasting blood glucose that is equal or greater than 7 mM. Therefore, the development of effective glucose biosensor has attracted extensive attention worldwide. Fluorescence- based strategies have sparked tremendous interest due to their rapid response, facile operation, and excellent sensitivity. Many fluorescent compounds have been employed for precise analysis of glucose, including quantum dots, noble metal nanoclusters, up-converting nanoparticles, organic dyes, and composite fluorescent microspheres. Silicon dot as promising quantum dots materials have received extensive attention, owing to their distinct advantages such as biocompatibility, low toxicity and high photostability. Methods: MnO2 nanosheets on the Si nanoparticles (NPs) surface serve as a quencher. Si NPs fluorescence can make a recovery by the addition of H2O2, which can reduce MnO2 to Mn2+, and the glucose can thus be monitored based on the enzymatic conversion of glucose by glucose oxidase to generate H2O2. Therefore, the glucose concentration can be derived by recording the fluorescence recovery spectra of the Si NPs. Results: This probe enabled selective detection of glucose with a linear range of 1-100 μg/mL and a limit of detection of 0.98 μg/mL. Compared with the commercial glucometer, this method showed favorable results and convincing reliability. Conclusion: We have developed a novel method based on MnO2 -nanosheet-modified Si NPs for rapid monitoring of blood glucose levels. By combining the highly sensitive H2O2/MnO2 reaction with the excellent photostability of Si NPs, a highly sensitive, selective, and cost-efficient sensing approach for glucose detection has been designed and applied to monitor glucose levels in human serum with satisfactory results.


The Analyst ◽  
2019 ◽  
Vol 144 (6) ◽  
pp. 1960-1967 ◽  
Author(s):  
Chao Chen ◽  
Pengcheng Zhao ◽  
Meijun Ni ◽  
Chunyan Li ◽  
Yixi Xie ◽  
...  

A temperature-induced sensing film consisting of poly(N-vinylcaprolactam) (PVCL), graphene oxide (GO) and glucose oxidase (GOD) was fabricated and used to modify a glassy carbon electrode (GCE).