Copper deposition-induced efficient signal amplification for ultrasensitive lateral flow immunoassay

2019 ◽  
Vol 282 ◽  
pp. 96-103 ◽  
Author(s):  
Meiling Tian ◽  
Lingli Lei ◽  
Wenyue Xie ◽  
Qimeng Yang ◽  
Chang Ming Li ◽  
...  
Biosensors ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 13
Author(s):  
Tao Peng ◽  
Xueshima Jiao ◽  
Zhanwei Liang ◽  
Hongwei Zhao ◽  
Yang Zhao ◽  
...  

The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory coronavirus 2 (SARS-CoV-2) is still raging all over the world. Hence, the rapid and sensitive screening of the suspected population is in high demand. The nucleocapsid protein (NP) of SARS-CoV-2 has been selected as an ideal marker for viral antigen detection. This study describes a lateral flow immunoassay (LFIA) based on colloidal gold nanoparticles for rapid NP antigen detection, in which sensitivity was improved through copper deposition-induced signal amplification. The detection sensitivity of the developed LFIA for NP antigen detection (using certified reference materials) under the optimized parameters was 0.01 μg/mL and was promoted by three orders of magnitude to 10 pg/mL after copper deposition signal amplification. The LFIA coupled with the copper enhancement technique has many merits such as low cost, high efficiency, and high sensitivity. It provides an effective approach to the rapid screening, diagnosis, and monitoring of the suspected population in the COVID-19 outbreak.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hyun-Kyung Oh ◽  
Kihyeun Kim ◽  
Jinhee Park ◽  
Hyungjun Jang ◽  
Min-Gon Kim

AbstractPaper-based biosensors based on lateral flow immunoassay (LFI) are promising candidates for POC diagnosis because of their ease of use and rapid target detection. However, the low sensitivity of LFI limits its application, and signal amplification has been used in numerous studies to increase its sensitivity. We developed an advanced trap LFI (α-trapLFI), a simple-to-use sensor, with an additional step for signal amplification. Here, signal amplification is automatically implemented following delayed release of enhancement solution induced by water-soluble polyvinyl alcohol tape. As the polyvinyl alcohol tape is exposed to water, its polymer structure is perturbed (within 5 min), allowing ions to pass through. This new sensor was designed to have a short time delay between the flow of solutions used for the immunoassay and signal amplification. The α-trapLFI was subsequently used to detect cortisol with high sensitivity (9.1 pg∙mL−1) over a broad detection range (0.01–1000 ng∙mL−1) in bodily fluids. Furthermore, an excellent correlation was obtained by analyzing 20 human real saliva samples using this sensor and a conventional ELISA (R2 = 0.90). The new sensor will be helpful in detecting various small molecules for simple, rapid, and portable POC diagnosis of stress disorders.


2022 ◽  
Author(s):  
Chuanyun Zha ◽  
Xingshuang An ◽  
Jiali Zhang ◽  
Lin Wei ◽  
Qi Zhang ◽  
...  

Fumonisin B1 (FB1) is a serious threat to the health of humans and animals. Herein, a lateral flow immunoassay based on the universal detection probes (goat anti-mouse IgG@Eu ) that...


2021 ◽  
Author(s):  
Hyun-Kyung Oh ◽  
Kihyeun Kim ◽  
Hyungjun Jang ◽  
Jinhee Park ◽  
Min-Gon Kim

Abstract Paper-based biosensors based on lateral flow immunoassay (LFI) are promising candidates for POC diagnosis because of their ease of use and rapid target detection. However, the low sensitivity of LFI limits its application, and signal amplification has been used in numerous studies to increase its sensitivity. We developed an advanced trap LFI (α-trapLFI), a simple-to-use sensor, with an additional step for signal amplification. Here, signal amplification is automatically implemented following delayed release of enhancement solution induced by water-soluble polyvinyl alcohol tape. As the polyvinyl alcohol tape is exposed to water, its polymer structure is perturbed (within 5 min), allowing ions to pass through. This new sensor was designed to have a short time delay between the flow of solutions used for the immunoassay and signal amplification. The α-trapLFI was subsequently used to detect cortisol with high sensitivity (9.1 pg∙mL-1) over a broad detection range (0.01–1000 ng∙mL-1) in bodily fluids. Furthermore, an excellent correlation was obtained by analyzing 20 human saliva samples using this sensor and a conventional ELISA (R2 = 0.90). The new sensor will be helpful in detecting various small molecules for simple, rapid, and portable POC diagnosis of stress disorders.


Sign in / Sign up

Export Citation Format

Share Document