Hysteretic behavior and parametric studies of a self-centering shear wall with tension-compression disc spring devices

2021 ◽  
Vol 150 ◽  
pp. 106929
Author(s):  
Yan Zhang ◽  
Longhe Xu
2021 ◽  
Vol 11 (13) ◽  
pp. 6094
Author(s):  
Hubdar Hussain ◽  
Xiangyu Gao ◽  
Anqi Shi

In this study, detailed finite element analysis was conducted to examine the seismic performance of square and circular hollow steel braces under axial cyclic loading. Finite element models of braces were constructed using ABAQUS finite element analysis (FEA) software and validated with experimental results from previous papers to expand the specimen’s matrix. The influences of cross-section shape, slenderness ratio, and width/diameter-to-thickness ratio on hysteretic behavior and compressive-tensile strength degradation were studied. Simulation results of parametric studies show that both square and circular hollow braces have a better cyclic performance with smaller slenderness and width/diameter-to-thickness ratios, and their compressive-tensile resistances ratio significantly decreases from cycle to cycle after the occurrence of the global buckling of braces.


2020 ◽  
Vol 20 (06) ◽  
pp. 2040007
Author(s):  
Limeng Zhu ◽  
Haipeng Yan ◽  
Po-Chien Hsiao ◽  
Jianhua Zhang

An innovative composite vertical connecting structure (CVC) with capacity carrying and energy-dissipating ability is proposed in this study, which could be used in prefabricated composite shear wall structural systems to enhance the resilience and seismic performance of structural system. The CVC structure is mainly composed of three parts, including the connecting zone, the capacity bearing zone characterized by high strength and elastic deforming ability, and the energy-dissipating zone assembled by replaceable metal dampers. The low-yield strength steel and high-strength steel are used, respectively, for the metal dampers in the energy-dissipating zone and the concrete-filled high-strength steel tubes in the bearing capacity zone to enhance the energy dissipation and self-centering abilities of CVC structures. The working mechanism is analyzed and validated through finite element models built in ABAQUS. The hysteretic behavior is simulated to evaluate their performance. First, the metal dampers are designed. The theoretical and finite elemental parametric analysis are carried out. According to the simulation results, the “Z-shaped” metal dampers exhibit better energy-dissipating ability than the rectangular shape, in which the “Z-shaped” metal dampers with 45∘ show the best performance. Simultaneously, the results of the models calculated by the finite element method and theoretical analysis work very well with each other. Furthermore, seven FE models of shear walls with CVC structures are designed. Monotonic and cyclic loading simulations are conducted. The failure modes and comprehensive mechanical performance are investigated and evaluated according to their calculated force–displacement curves, skeleton curves, and ductility coefficients. The results indicate that the CVC structure delivered preferable lateral-bearing capacity and displacement ductility. Finally, according to available design standards, the lateral stiffness of CVC structures could be conventionally controlled and some practical design recommendations are discussed.


2019 ◽  
Vol 2019 ◽  
pp. 1-13 ◽  
Author(s):  
Bo Hu ◽  
Xinyu Wei ◽  
Henglin Lv ◽  
Tribikram Kundu ◽  
Ning Li

Three single reinforcement concrete (RC) frames, including 1 reference specimen and 2 specimens strengthened with shear walls, were fabricated and subjected to low cyclic loadings, in order to evaluate seismic performances of strengthened single frame structures with exterior cantilevers. Through comparison and analysis of failure mode, hysteretic behavior, skeleton curve, energy dissipation, strength, and stiffness degradation of the tested frames, the validity of the shear wall-based reinforcement method for single frames was verified. Test results indicate that the stiffness and load-bearing capacities of strengthened frames increased considerably in comparison with the reference frame. A “strong column-weak beam” failure pattern was observed on the cantilever side, and the failure of the shear wall was always prior to the column, which can increase the structural redundancy and improve the failure mechanism and seismic performance of an existing single frame.


2011 ◽  
Vol 243-249 ◽  
pp. 1450-1455 ◽  
Author(s):  
Wan Lin Cao ◽  
Wen Jiang Zhang ◽  
Jian Wei Zhang ◽  
Hong Ying Dong

In view of the proposal of embedded steel plate concrete shear wall with concrete filled steel tube columns which contains a new kind shear connector of tie-bars through the circular holes linking concrete layers on both sides of the plate. In order to prove the seismic performance of walls with circular holes on the plate, three steel plate shear wall specimens, including the plate without holes bolted with columns, welded with columns, and the perforated plate welded with columns, were tested under cyclic loading. According to the results, the load-bearing capacity, ductility, energy dissipation, hysteretic behavior and failure phenomena were analyzed. It is showed that the load-bearing capacity of the three specimens were quite close. However, the wall with perforated steel plate has better ductility, energy dissipation and hysteretic behavior. So, it is an effective way to improve the seismic performance of walls by means of embedded perforated steel plate instead of ordinary ones.


1990 ◽  
Vol 6 (1) ◽  
pp. 1-14 ◽  
Author(s):  
S. A. Adham ◽  
V. Avanessian ◽  
G. C. Hart ◽  
R. W. Anderson ◽  
J. Elmlinger ◽  
...  

Experimental investigations were conducted to evaluate the lateral load-deflection characteristics of lightgage steel stud/gypsum wallboard panel combinations subjected to lateral cyclic loads. In all, six 8′ × 8′ specimens were tested. A reasonable one-to-one correspondence between the strap area increase and the increase in the contribution from the strap to the overall loadcarrying capacity of the panel at intermediate and high drift ratios was observed. The panel lateral stiffness for a given stabilized cycle degraded by about 7% to 15% as compared with the lateral stiffness of the corresponding virgin cycle. Lateral stiffness degradation increased as the drift ratios became larger. The energy dissipation ability of the panels in the stabilized cycle was about 60% of the virgin cycle. An average value of equivalent viscous damping for all the cycles based on panel hysteretic behavior was about 12%.


2013 ◽  
Vol 351-352 ◽  
pp. 734-737
Author(s):  
Wan Shin Park ◽  
Young Soo Chun ◽  
Hyun Do Yun ◽  
Soo Yeon Seo ◽  
Jin Kyu Song ◽  
...  

This paper addresses the seismic behavior of coupling beams with headed reinforcing bars in coupled shear wall system. Test variable included the replacement ratios of headed reinforcing bars. The results show that Specimen HB 50 exhibits a better stable behavior in comparison with Specimens Specimen CON and Specimen HB 30. Test results showed that the amount of diagonal reinforcing bars in the coupling beam may be reduced when headed reinforcing bars are utilized.


2013 ◽  
Vol 663 ◽  
pp. 159-163
Author(s):  
Hae Jun Yang ◽  
Hyun Do Yun

In this study, two reinforced concrete (RC) squat shear walls with height-to-length ratio of 0.55 and non-ductile reinforcement details are tested under reversed cyclic loading. Emphasis of the study is placed on the hysteretic behavior and cracking procedure of RC squat shear walls in accordance with the presence and absence of vertical seam on the wall panel. Two specimens had the same rectangular cross-section of 1,100 x 50mm, with wall panel heights of 600mm. To investigate the effect of vertical seams on the wall panel on the structural behavior of shear wall, one wall (CON-S) with three vertical seams with dimension of 260 x 40mm was made and the other (CON-N) was a solid wall without seams. The test results indicated that a squat shear wall with vertical seams exhibited more stable hysteretic behavior than a solid shear wall. Vertical seams on the wall panel improve the ductility and energy dissipation capacity but decrease the maximum strength of RC non-ductile squat shear wall.


Sign in / Sign up

Export Citation Format

Share Document