Micro/nanoscale multistructures of oxide layers on Ti6Al4V achieved by acid etching and induction heating for high osteogenic activity in vitro

2020 ◽  
Vol 393 ◽  
pp. 125816
Author(s):  
Ning-bo Li ◽  
Sheng-jun Sun ◽  
Han-ying Bai ◽  
Wen-hua Xu ◽  
Gui-yong Xiao ◽  
...  
Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 473
Author(s):  
Paolo Canepa ◽  
Giuseppe Firpo ◽  
Elena Gatta ◽  
Roberto Spotorno ◽  
Paolo Giannoni ◽  
...  

We present a two-step surface modification process to tailor the micro and nano morphology of niobium oxide layers. Niobium was firstly anodized in spark regime in a Ca- and P-containing solution and subsequently treated by acid etching. The effects of anodizing time and applied potential on the surface morphology is investigated with SEM and AFM, complemented by XPS compositional analysis. Anodizing with a limiting potential of 250 V results in the fast growth of oxide layers with a homogeneous distribution of micro-sized pores. Cracks are, however, observed on 250 V grown layers. Limiting the anodizing potential to 200 V slows down the oxide growth, increasing the anodizing time needed to achieve a uniform pore coverage but produces fracture-free oxide layers. The surface nano morphology is further tuned by a subsequent acid etching process that leads to the formation of nano-sized pits on the anodically grown oxide surface. In vitro tests show that the etching-induced nanostructure effectively promotes cell adhesion and spreading onto the niobium oxide surface.


Author(s):  
M. John Hicks

Acid-etching of enamel surfaces has been performed routinely to bond adhesive resin materials to sound dental enamel as a caries-preventive measure. The effect of fluoride pretreatment on acid-etching of enamel has been reported to produce inconsistent and unsatisfactory etching patterns. The failure to obtain an adequate etch has been postulated to be due to fluoride precipitation products deposited on the enamel surface. The purpose of this study was to evaluate the effects of fluoride pretreatment on acid-etching of carieslike lesions of human dental enamel.Caries-like lesions of enamel were created in vitro on human molar and premolar teeth. The teeth were divided into two fluoride treatment groups. The specimens were exposed for 4 minutes to either a 2% Sodium Fluoride (NaF) solution or a 10% Stannous Fluoride (SnF2) solution. The specimens were then washed in deionized-distilled water. Each tooth was sectioned into four test regions. This was carried out to compare the effects of various time exposures (0 to 2 minutes) and differing concentrations (10 to 60% w/w) of phosphoric acid (H3PO4) on etching of caries-like lesions. Standard preparation techniques for SEM were performed on the specimens.


Coatings ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 505
Author(s):  
Krzysztof Aniołek ◽  
Bożena Łosiewicz ◽  
Julian Kubisztal ◽  
Patrycja Osak ◽  
Agnieszka Stróż ◽  
...  

Titanium and its alloys are among the most promising biomaterials for medical applications. In this work, the isothermal oxidation of Ti-6Al-7Nb biomedical alloy towards improving its mechanical properties, corrosion resistance, and bioactivity has been developed. The oxide layers were formed at 600, 700, and 800 °C for 72 h. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), 3D profilometry, and microindentation test, were used to characterize microstructure, surface geometrical structure, and the hardness of the diphase (α + β) Ti-6Al-7Nb alloy after oxidation, respectively. In vitro corrosion resistance tests were carried out in a saline solution at 37 °C using the open-circuit potential method and potentiodynamic measurements. Electronic properties in the air were studied using the Scanning Kelvin Probe (SKP) technique. The bioactivity test was conducted by soaking the alkali- and heat-treated samples in simulated body fluid for 7 days. The presence of apatite was confirmed using SEM/EDS and Fourier Transform Infrared Spectroscopy (FTIR) studies. The thickness of oxide layers formed increased with the temperature growth from 0.25 to 5.48 µm. It was found that with increasing isothermal oxidation temperature, the surface roughness, hardness, corrosion resistance, and contact potential difference increased. The Ti-6Al-7Nb alloy after oxidation revealed the HAp-forming ability in a biological environment.


RSC Advances ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 6124-6130
Author(s):  
Yanxia Chi ◽  
Sipeng An ◽  
Yunpeng Xu ◽  
Mingda Liu ◽  
Jie Zhang

A sandblasted, acid-etched hydroxyapatite (SLA-HA) composite coating on ultrafine-grained titanium was synthesized by sandblasting, acid etching and electrophoresis deposition.


2004 ◽  
Vol 18 (3) ◽  
pp. 253-259 ◽  
Author(s):  
Fabiana Mantovani Gomes França ◽  
Flávio Henrique Baggio Aguiar ◽  
Alex José Souza dos Santos ◽  
José Roberto Lovadino

The aim of this in vitro study was to evaluate quantitatively the microleakage in class V cavities restored with one-bottle and self-etching adhesive systems with and without previous acid etching. Two one-bottle adhesive systems (Single Bond and Prime & Bond 2.1) and one self-etching adhesive system (Clearfil Mega Bond) were used in this study. One hundred and twenty sound human premolar teeth were randomly divided into 6 groups, and 20 class V restorations were prepared in the root dentin to test each bonding system. Each bonding system was used with and without acid etching. Specimens were prepared, dyed with 2% methylene blue, sectioned, triturated, and evaluated with an absorbance spectrophotometer test in order to quantify the infiltrated dye. Results were statistically evaluated by ANOVA and Tukey-Kramer test. No statistically significant differences were found among the adhesive systems when no etching agent was used. However, the Single Bond adhesive system showed statistically significant lower microleakage means than Clearfil Mega Bond and Prime & Bond 2.1 when 37% phosphoric acid was used. Single Bond and Clearfil Mega Bond adhesive systems presented similar behavior when the manufacturers' instructions were followed.


2019 ◽  
Vol 10 (4) ◽  
pp. 304-309
Author(s):  
Larissa Costa Santos ◽  
Ravana Angelini Sfalcin ◽  
Eugenio José Garcia ◽  
Fátima Antônia Aparecida Zanin ◽  
Aldo Brugnera Junior ◽  
...  

Introduction: Microleakage has been reported to cause dentin hypersensitivity because of the passage of bacteria and their products through the restoration-tooth interface and is one of the main reasons for replacement of restorations. CO2 laser can be used for treatment of dentin hypersensitivity. Thus, this study aimed to evaluate in vitro the microleakage in composite restorations following surface pretreatment with acid etching and CO2 laser. Methods: Twelve human caries-free primary molars were selected. Class II cavities were prepared on occlusal mesial and occlusal distal surfaces. Specimens were randomly divided into four groups (n=6): Group 1 (G1) – 37% phosphoric acid gel etching + Beautiful-Bulk Restorative – Giomer (Shofu Inc); Group 2 (G2) – 37% phosphoric acid gel etching + SDR Bulk-Fill Flow (Dentsply); Group 3 (G3) – CO2 laser irradiation + Beautiful-Bulk Restorative – Giomer (Shofu Inc); Group 4 (G4) – CO2 laser irradiation + SDR Bulk-Fill Flow (Dentsply). Surfaces were restored with bonding agent (Natural Bond DE, DFL). Specimens were cut longitudinally and immersed in 0.5% methylene blue solution for 4 hours. Microleakage scores were assessed under a magnifying glass at x3,5 and qualitatively analyzed by scanning electron microscope (SEM). Data were analyzed using nonparametric Wilcoxon test (P < 0.05). Results: Scores prevailed between 0 and 2, however, no statistically significant difference was found among the groups (P= 0.05). Conclusion: It could be concluded that all composite resins bulk fill did not show significant difference among them regarding microleakage using either CO2 laser or 37% phosphoric acid etching.


Sign in / Sign up

Export Citation Format

Share Document