Shear test results for cohesion and friction coefficients for different granular materials: scaling implications for their usage in analogue modelling

2000 ◽  
Vol 324 (1-2) ◽  
pp. 1-16 ◽  
Author(s):  
W.P. Schellart
2014 ◽  
Vol 10 (3) ◽  
pp. 389-397 ◽  
Author(s):  
Wenxiong Huang ◽  
Liya Huang ◽  
Daichao Sheng ◽  
Scott W. Sloan

Soft Matter ◽  
2022 ◽  
Author(s):  
Aile Sun ◽  
Yinqiao Wang ◽  
Yangrui Chen ◽  
Jin Shang ◽  
Jie Zheng ◽  
...  

We perform a systematic experimental study to investigate the velocity fluctuations in the two-dimensional granular matter of low and high friction coefficients subjected to cyclic shear of a range of...


2010 ◽  
Vol 97-101 ◽  
pp. 724-727 ◽  
Author(s):  
Qun Shan Ye ◽  
Shao Peng Wu

Dynamic shear test and creep shear test were employed to investigate the dynamic properties of various fiber modified asphalt binders with the fiber content of 1.0%. The test results indicate that complex shear modulus of asphalt binders containing fibers are increased while the phase angles are decreased greatly, which implies that the asphalt binder is reinforced by the addition of fibers and the elastic property of asphalt binder is improved significantly, especially at high frequency levels. The total strain during loading period and the residual strain after the creep shear test of asphalt binders are reduced greatly by the addition of fibers. Furthermore, the creep modulus of fiber modified asphalt binders is increased and the development rate versus loading time of creep modulus is decreased.


2018 ◽  
Vol 323 ◽  
pp. 385-392 ◽  
Author(s):  
Dong Lei ◽  
Jinfeng Huang ◽  
Wenxiang Xu ◽  
Wenchao Wang ◽  
Pei Zhang

2016 ◽  
Vol 2016 (1) ◽  
pp. 000219-000226 ◽  
Author(s):  
Priscila Brown ◽  
Rachel Wynder ◽  
Dustin Tenney ◽  
Stevan Hunter

Abstract This paper continues the work of reference [1], evaluating shear test results of Cu ball bonds over a variety of probe marks in two different pad aluminum (Al) thicknesses (0.8μm and 3μm). The presence of invasive probe marks on thick Al bond pads lowers certain shear force results.. Lower values of shear force imply reduced Cu bond reliability. Physical factors are investigated relating to poor intermetallic (IMC) formation in the Cu wirebond and bond shear force. Optical microscopic image analysis of Cu bonds, bond contact areas and Al “splash” are studied for correlation with the shear test results. Percent IMC coverage of bond contact areas decrease when invasive probe marks are present beneath the bond, which in turn may reduce the shear force. Probe mark features are studied to discover the characteristics of greatest influence on % IMC coverage and shear test values in each of the pad metal thicknesses.


2018 ◽  
Vol 26 (1) ◽  
pp. 9-18
Author(s):  
Dooyong Cho ◽  
Jinwoong Choi ◽  
Hoseong Jeong

When Perfobond Rib shear connectors are used as flexural materials in structures such as bridges, they show flexural shear behavior due to external force, rather than direct shear behavior. The aim of this study is thus to analyze the difference between both behaviors. First, we prepared a specimen to analyze direct shear behavior using Perfobond Rib shear connectors, analyzed the characteristics of behavior with a push-out test and proposed a formula of shear resistance assessment. Proposed formula shows a relatively good fit with less than 10% error. A flexural shear test was then conducted based on the result of the direct shear test. Based on the static flexural test it analyzed the flexural behavior and the flexural shear stress it calculated. Direct shear stress and EN 1994-1-1 to lead and be calculated, it compared the flexural shear stress and it analyzed in about the shear resistance stress which it follows in load direction. Finally, we compared both test results, and the comparison showed that the flexural shear stress is approximately 6% stronger than the direct shear stress.


1987 ◽  
Vol 51 (3) ◽  
pp. 231-236 ◽  
Author(s):  
G. Haaker
Keyword(s):  

2003 ◽  
Vol 783 ◽  
Author(s):  
Megan M. Owens ◽  
Joseph W. Soucy ◽  
Thomas F. Marinis ◽  
Kevin A. Bruff ◽  
Henry G. Clausen

ABSTRACTLTCC substrates for fine pitch (1.0 mm and 0.8 mm) CSP applications have been designed, fabricated, and assembled. The assembly process, including ball grid array (BGA) solder ball attach, die mount, wire bond, and glob top is described. The material and physical design interaction issues that emerged during development are discussed.The initial CSP design was conventional, with co-fired yellow gold (Au) vias and capture pads and post-fired solderable gold (PtPdAu) pads for solder ball attachment. Because LTCC tape shrinks during co-fire, solder pads were applied post co-fire to ensure proper mating with existing test fixtures and to provide the best alignment relative to the CSP body. Solder pad to capture pad misalignment was visible following solder pad firing. After CSP attachment to a test board, electrical tests revealed opens. Investigation led to the following conclusions. The decreased solder pad diameter necessary to accommodate the fine pitch design was significant relative to the area allocated for the underlying via and capture pad. Misalignment that would have been hidden under larger solder pads was exposed. Even when the capture pad surface was not visibly exposed, the offset solder pad meant less material between the capture pad and the solder ball, less of a barrier to solder leaching. Solder leaching into the yellow gold, observed after CSP removal from the test board, was the cause of the electrical disconnects. In the second design, the capture pad was eliminated in order to discourage leaching by reducing the volume of yellow gold available to alloy with the solder pad during co-fire. Reflow operations still resulted in leached solder pads. A third design replaced the first-layer via yellow gold with a solderable gold. This design proved to be robust.While developing designs and fabricating these prototypes, it was noted that all ball failures consistently occurred between the solder pad and the LTCC substrate. To investigate adhesion using different metallizations, shear tests were performed on LTCC substrates with either post-fired solder pads or co-fired pads. To investigate how the substrate material affects adhesion, alumina CSPs were also sheared. Shear test results are presented.


Sign in / Sign up

Export Citation Format

Share Document