scholarly journals Geosynchronous Satellite Orbit Determination

1997 ◽  
Vol 165 ◽  
pp. 351-354
Author(s):  
Sergei Rudenko

AbstractThe paper presents the results of the orbit determination of geosynchronous satellites derived from 1921 positional observations of a few dozens of satellites obtained at the double wide-angle astrograph DWA (D=0.4m, F=2m) of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine in 1985–1991. The observations cover the longitude range from 19°Wto 80°E. Orbital inclination of the observed objects is less than 3°. The mean values of the rms residuals are 066 in R.A. and 101 in Dec. over all processed orbital arcs.

Author(s):  
J Grøndahl-HANSEN ◽  
N Agerlin ◽  
L S Nielsen ◽  
K Danø

An enzyme-linked immunosorbent assay (ELISA) was developed for the measurement of human urokinase-type plasminogen activator (u-PA) in plasma and serum. Microtiter plates were coated with a monoclonal antibody and incubated with standard or sample. Bound u-PA was quantitated with polyclonal antibodies conjugated with biotin, followed by avidin-peroxidase. The assay was 10-fold as sensitive as other previously reported ELISAs, the detection limit being approximately 1 pg of u-PA in a volume of 100 μl with a linear dose-response up to 15 pg of u-PA. The assay detected active u-PA and its inactive proenzyme form equally well and the recovery of both forms was higher than 90% in plasma. A variety of structurally related proteins, including t-PA, were tested, but no reaction with proteins other than u-PA and its amino-terminal degradation product were observed. The intra-assay and inter-assay coefficients of variation for determination of u-PA in plasma were 7.6% and 8.4%, respectively. The assay was equally applicable to serum. The values obtained with plasma and serum were similar, and the results were not affected by small variations in the preparation of the samples. The ELISA was used to measure the concentration of u-PA in plasma from 34 healthy donors. The mean values for u-PA in plasma from healthy donors was 1.1 ng/ml ± 0.3 ng/ml (SD) (range 0.6 - 1.5 ng/ml). No significant differences were found between men and women and no correlation between u-PA concentration and age could be demonstrated.The mean u-PA concentration in plasma from healthy donors obtained in this study is substantially lower than that reported by others. This might be due to different methods of determination of the protein content of the standard preparations or to differences in the specificity of the assays.


2016 ◽  
Vol 46 (6) ◽  
pp. 1014-1018 ◽  
Author(s):  
Charline Zaratin Alves ◽  
Lennis Afraire Rodrigues ◽  
Carlos Henrique Queiroz Rego ◽  
Josué Bispo da Silva

ABSTRACT: Crambe is a rapeseed with high oil content and can be used as a winter cover or as a source of raw material for the production of biodiesel, however espite the growing interest in the culture, research on the subject is still incipient, especially concerning the seed production and analysis technology. The purpose of this study is to evaluate the physiological quality of crambe seeds, 'FMS Brilhante' cultivar, by testing the pH of exudate. Five seed lots were submitted to the determination of water content and the tests of germination and vigor (first count, emergence and tetrazolium). In the conduction of pH exudate test, temperatures (25 and 30oC), and periods of seed imbibition in water (15, 30 and 45 minutes) were tested. The experiment was conducted in a completely randomized manner, with four replicates, and the mean values were compared by the Tukey test at 5% probability; Pearson correlation between the pH of the exudate and initial tests was also made. Testing the pH of exudate is promising for separating lots of crambe seeds and the following combinations of 25°C/30 minutes or 30°C/45 minutes can be used.


2013 ◽  
Vol 353-356 ◽  
pp. 3456-3459 ◽  
Author(s):  
Qiao Li Kong ◽  
Jin Yun Guo ◽  
Li Tao Han

DORIS is a kind of advanced space-geodetic techniques applied in satellite orbit tracking and measuring. As the first ocean dynamic environmental satellite in China, the HY-2 satellite is equipped with the Doppler orbitography and radiopositioning integrated by satellite (DORIS) tracking system for the precise orbit determination. In particular, the investigation of our work has focused on accuracy analysis of orbit determination using simulated DORIS data given different observation noises, besides the relationship is investigated between accuracy and computation time and the number of ground beacons evenly distributed around the world. Experiment results show that observation noises can affect the accuracy of orbit determination directly, and the number of DORIS ground beacons decides the accuracy and computation time of obit determination in the condition of ground beacons are evenly distributed around the world, therefore, during the process of obit determination, we should optimize the ground beacon station distribution to achieve the best accuracy of obit determination using DORIS tracking data.


Author(s):  
S. J. Lee ◽  
B. J. Gilmore

Abstract A probabilistic model and methods to determine the means and variances of the velocity and acceleration of stochastically-defined planar pin jointed kinematic chains are presented. The presented model considers the effect of tolerances on link length and radial clearance and uncertainty of pin location as a net effect on the link’s effective length. The determination of the mean values and variances of the output variables requires the calculation of sensitivities of secondary variables with respect to the random variables. It is shown that this computation is straightforward and can be accomplished by a conventional kinematic analysis package. Thus, the concepts of tolerance and clearance have been captured by the model and analysis. The only input data is the nominal linkage model and statistical information. The “effective link length” model is shown to be applicable to both analytical solution and Monte Carlo simulation. The results from both methods are compared. This paper solves the higher-order kinematics problem for the probabilistic design analysis of stochastically defined mechanisms.


1967 ◽  
Vol 13 (10) ◽  
pp. 900-908 ◽  
Author(s):  
Brigitta Mellerup

Abstract A method for the determination of serum arginase is given which combines the enzymatic formation of urea with the sensitive method of Coulombe (1) for measuring this substance. This procedure allows more accurate determinations in the normal range than do previous methods described and is convenient for clinical routine. Significant difference is found between the mean values of normal men and women, 3.9 units/L. for the former and 2.9 units/L. for the latter.


2012 ◽  
Vol 36 (1) ◽  
pp. 45-51 ◽  
Author(s):  
YN Jolly ◽  
TR Choudhury ◽  
A Islam ◽  
NI Suravi ◽  
MS Sultana

A background study of the chemical constituents of some environmental samples - tannery   complex sand, river water, river sediment and river fishes collected from the Relocated Hazaribagh   Tannery Complex (RHTC) area, was carried out. In sand samples the mean values for pH, EC and   soluble salts were found to be 8.49, 0.02 mS/cm and 11.72 mg/kg and the mean concentrations of   elements K, Ca, Ti, Mn, Fe, Co, Zn, As, Pb, Rb and Sr were 94.8, 68.5, 16.6, 2.68, 129, 1.19,   0.23, 0.70, 0.32, 0.62 and 1.03 mg/kg, respectively. In river water samples the average   concentrations of K, Ca, Mn, Fe, Zn, As, Rb, Sr, SO 4 -2, PO4 -3, Cl-1 and NO3 -1 were 13.09, 178,   0.41, 1.82, 0.073, 0.031, 0.010, 0.48, 0.057, 0.019, 15.6, 5.68 mg/l and the average values for pH,   EC, DO, BOD, SS and DS were 8.02 and 0.35 mS/cm, 6.29, 4.21, 0.06, 0.36 mg/l, respectively.   The elements K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, As, Rb, Sr and Pb were measured in river sediment   samples at the limit of 205, 155, 67, 6.02, 17.2, 798, 1.10, 1.24, 1.99, 0.31, 2.34, 2.63 and 0.35   mg/kg, respectively. In some locally available fishes like tengra, puti, baim, taki, shrimp, chanda   and baila, only the elements K, Ca, Fe, Zn, Rb and Sr could be measured in all species of fishes in   the range of 0.39 - 1.01, 0.68 - 2.29, 60.6 - 125, 46.3 - 174, 2.84 - 61.8 and 12.3 - 38.0% in mg/kg,   respectively. In the light of the overall study, the chemical constituent levels of the environmental   samples of the RHTC area at present are low and the environment is not yet contaminated. DOI: http://dx.doi.org/10.3329/jbas.v36i1.10919Journal of Bangladesh Academy of Sciences, Vol. 36, No. 1, 45-51, 2012


2013 ◽  
Vol 58 (No. 5) ◽  
pp. 277-283 ◽  
Author(s):  
V. Ledecky ◽  
A. Valencakova-Agyagosova ◽  
J. Lepej ◽  
Z. Frischova ◽  
S. Hornak ◽  
...  

The aim of this study was to determine reference values of carcinoembryonic antigen and cancer antigen in 32 clinically healthy bitches. The average age of the bitches in each group was as follows: small breeds 3.50 &plusmn; 2.30, medium breeds 3.83 &plusmn; 3.21, large breeds 6.00 &plusmn; 3.22 and giant breeds 2.40 &plusmn; 2.43. The average weight in each group was as follows: 1<sup>st</sup> group 7.94 kg &plusmn; 1.84, 2<sup>nd</sup> group 22.38 kg &plusmn; 2.77, 3<sup>rd</sup> group 35.94 kg &plusmn; 7.16, and 4<sup>th</sup>&nbsp;group 52.75 kg &plusmn; 5.04. The cancer markers were determined using human kits. The mean values of the carcinoembryotic antigen markers &plusmn; SD were as follows: 1<sup>st</sup> group 0.18 &plusmn; 0.03, 2<sup>nd</sup> group 0.20 &plusmn; 0.03, 3<sup>rd</sup> group 0.22 &plusmn; 0.01, 4<sup>th</sup> group 0.18 &plusmn; 0.04. The statistical significance for the carcinoembryonic antigen markers was P = 0.0042**. The values of cancer antigen markers &plusmn; SD were: 4.90 &plusmn; 1.04, 4.80 &plusmn; 1.13, 5.90 &plusmn; 1.22, and 4.72 &plusmn; 0.97, respectively. The cancer antigen values were statistically insignificant (P = 0.1762). Based on obtained values of the mean 95%, we expect a standard for carcinoembryonic antigen of 0.00&ndash;0.23 ng/ml and for cancer antigen 0.0&ndash;7.00 IU/ml. The results of the present study show that it is possible to use human kits for the determination of carcinoembryonic antigen and cancer antigen in clinically healthy bitches using the radioimmunoassay method. &nbsp;


2015 ◽  
Vol 1 (6) ◽  
pp. 270
Author(s):  
Audumbar Digambar Mali ◽  
Ritesh Bathe ◽  
Manojkumar Patil ◽  
Ashpak Tamboli

Simple, fast and reliable spectrophotometric methods were developed for determination of Levocetirizine in bulk and pharmaceutical dosage forms. The solutions of standard and the sample were prepared in methanol. The quantitative determination of the drug was carried out using the zero order derivative values measured at 230 nm and the area under the curve method values measured at 227-234 nm (n=2). Calibration graphs constructed at their wavelengths of determination were linear in the concentration range of Levocetirizine using 5-25?g/ml (r=0.998 and r=0.999) for zero order and area under the curve spectrophotometric method. All the proposed methods have been extensively validated as per ICH guidelines. There was no significant difference between the performance of the proposed methods regarding the mean values and standard deviations. Developed spectrophotometric methods in this study are simple, accurate, precise and sensitive to assay of Levocetirizine in tablets.


1991 ◽  
Vol 113 (1) ◽  
pp. 84-90 ◽  
Author(s):  
S. J. Lee ◽  
B. J. Gilmore

A probabilistic model and methods to determine the means and variances of the velocity and acceleration within stochastically-defined planar pin jointed kinematic chains are presented. The presented model considers the effect of tolerances on link length and radial clearance and uncertainty of pin location as a net effect on the link’s effective length. The determination of the mean values and variances of the output variables requires the calculation of sensitivities of secondary variables with respect to the random variables. It is shown that this computation is straightforward and can be accomplished by a conventional kinematic analysis package. Thus, the concepts of tolerance and clearance have been captured by the model and analysis. The only input data is the nominal linkage model and statistical information. The “effective link length” model is shown to be applicable to both analytical solution and Monte Carlo simulation. The results from both methods are compared. This paper solves the higher-order kinematics problem for the probabilistic design analysis of stochastically defined mechanisms.


Sign in / Sign up

Export Citation Format

Share Document