scholarly journals Serological divergence of Dobrava and Saaremaa hantaviruses: evidence for two distinct serotypes

2002 ◽  
Vol 128 (1) ◽  
pp. 99-103 ◽  
Author(s):  
K. BRUS SJÖLANDER ◽  
I. GOLOVLJOVA ◽  
V. VASILENKO ◽  
A. PLYUSNIN ◽  
Å. LUNDKVIST

In order to investigate the serological relationship of Dobrava hantavirus (DOBV, originating from Slovenia) and the Dobrava-like Saaremaa virus (SAAV, recently discovered in Estonia) we analysed 37 human serum samples, 24 from Estonia and 13 from the Balkans, by focus reduction neutralization test (FRNT). Most of the Estonian sera (19), including all sera from Saaremaa island (12), reacted with higher FRNT end-point titres to the local SAAV; the majority of them (15 and 11, respectively), with at least fourfold or higher titres to SAAV than to DOBV. In contrast, out of the 13 sera collected in Slovenia, Bosnia-Herzegovina and Greece, only one reacted more strongly with SAAV (with a twofold higher titre), while 10 of these sera reacted more strongly with the local DOBV (9/10 with fourfold or higher titres). These results indicate that DOBV and SAAV define unique hantavirus serotypes.

2011 ◽  
Vol 18 (11) ◽  
pp. 1889-1894 ◽  
Author(s):  
Minetaro Arita ◽  
Masae Iwai ◽  
Takaji Wakita ◽  
Hiroyuki Shimizu

ABSTRACTIn the Global Polio Eradication Initiative, laboratory diagnosis plays a critical role by isolating and identifying poliovirus (PV) from the stool samples from acute flaccid paralysis (AFP) cases. In recent years, reestablishment of PV circulation in countries where PV was previously eliminated has occurred because of decreased herd immunity, possibly due to poor vaccination coverage. To monitor the vulnerability of countries to PV circulation, surveillance of neutralizing-antibody titers against PV in susceptible populations is essential in the end game of the polio eradication program. In this study, we have developed a PV neutralization test with type 1, 2, and 3 PV pseudoviruses to determine the neutralizing-antibody titer against PV in human serum samples. With this test, the neutralizing-antibody titer against PV could be determined within 2 days by automated interpretation of luciferase signals without using infectious PV strains. We validated the pseudovirus PV neutralization test with 131 human serum samples collected from a wide range of age groups (ages 1 to >60 years) by comparison with a conventional neutralization test. We found good correlation in the neutralizing-antibody titers determined by these tests. These results suggest that a pseudovirus PV neutralization test would serve as a safe and simple procedure for the measurement of the neutralizing-antibody titer against PV.


2015 ◽  
Vol 144 (5) ◽  
pp. 1107-1116 ◽  
Author(s):  
J. E. LIMONGI ◽  
R. C. OLIVEIRA ◽  
A. GUTERRES ◽  
S. F. COSTA NETO ◽  
J. FERNANDES ◽  
...  

SUMMARYThis paper describes the diversity of rodent fauna in an area endemic for hantavirus cardiopulmonary syndrome (HCPS) in Brazil, the population dynamics and the relationship of rodents with hantavirus in the Cerrado (savanna-like) biome. Additionally, an analysis is made of the partial S segment sequences of the hantaviruses obtained from serologically confirmed human HCPS cases and from rodent specimens. Rodents were collected during four campaigns. Human serum samples were collected from suspected cases of HCPS at hospitals in the state of Minas Gerais. The samples antibody-reactive by ELISA were processed by RT–PCR. The PCR product was amplified and sequenced. Hantavirus was detected only in Necromys lasiurus, the wild rodent species most prevalent in the Cerrado biome (min-max: 50–83·7%). All the six human serum samples were hantavirus seropositive and five showed amplified PCR products. The analysis of the nucleotide sequences showed the circulation of a single genotype, the Araraquara hantavirus. The environmental changes that have occurred in the Cerrado biome in recent decades have favoured N. lasiurus in interspecific competition of habitats, thus increasing the risk of contact between humans and rodent species infected with hantavirus. Our data corroborate the definition of N. lasiurus as the main hantavirus reservoir in the Cerrado biome.


2019 ◽  
Vol 15 (6) ◽  
pp. 678-684
Author(s):  
Biljana Nigović ◽  
Jakov Vlak

Background: High uric acid serum level, hyperuricemia, is now associated with many diseases such as gout, chronic kidney disease, hypertension, coronary artery disease and diabetes. Febuxostat is a novel selective xanthine oxidase inhibitor approved for the treatment of hyperuricemia. Objective: The aim of this study was to develop a first analytical method for the simultaneous determination of febuxostat and uric acid. Methods: An unmodified boron-doped diamond electrode provided concurrent quantitation of drug at low levels and uric acid, which has clinical significance in the diagnosis and therapy of hyperuricemia, at relatively high concentrations. The direct square-wave voltammetric method was applied to the analysis of both analytes in human serum samples. Results: Under the optimized conditions, the linear response of peak current on febuxostat concentration was achieved in the range from 7.5 × 10-7 to 3 × 10-5 M, while uric acid showed two linear ranges of 5 × 10-6 - 5 × 10-5 M and 5 × 10-5 - 2 × 10-4 M. The method was successfully utilised for quantification of both analytes in human serum samples. Good recoveries were obtained without interference from common inorganic cations and anions as well as glucose, dopamine, ascorbic and folic acids at concentrations expected in physiological conditions. Conclusion: The great benefits of developed method are fast analysis (only 7.5 s for run), low cost and simplicity of performance.


1990 ◽  
Vol 126 (1) ◽  
pp. 159-168 ◽  
Author(s):  
A. N. Thakur ◽  
R. Coles ◽  
A. Sesay ◽  
B. Earley ◽  
H. S. Jacobs ◽  
...  

ABSTRACT A previously described in-vitro rat granulosa cell plasminogen activator bioassay for FSH has been modified and applied in the assay of human serum. This modified method consists of exposing the diethylstilboestrol-stimulated granulosa cells from 25- to 26-day-old rats to FSH or test substance for 3·5 h in wells coated with 125I-labelled fibrinogen and treated with thrombin. Following stimulation with FSH, the dose-related production of plasminogen activator was measured as the degree of 125I-labelled fibrinolysis in the presence of added plasminogen. Using the urinary FSH/LH bioassay reference preparation as the assay standard, the useful range of the assay was 0·3–15IU/l, with an assay sensitivity of 0·3 IU/l. As determined using purified glycoprotein hormone preparations, the assay was highly specific for FSH. The minor degree of FSH bioactivity measured in some of the hormone preparations was accounted for by the amount of FSH contamination in these preparations. To abolish interference caused by unknown serum factors, we heat-treated the serum samples for 15 min at 56 °C before the assay. The results indicated that neither immunoreactivity nor bioactivity was affected by this treatment. Furthermore, heat-treated human sera gave responses parallel to the standard curve at the three dose levels (2, 4 and 8 μl) studied. We used this bioassay to estimate the FSH-like bioactivity in 15 human serum samples. The estimates of immunoreactive FSH in these samples correlated well with the corresponding FSH bioactivity (r = 0·745, n = 15 and P < 0·05). The results indicate that with this sensitive and rapid (completed within 24 h) bioassay, it should be possible to measure FSH bioactivity in heat-treated human serum samples. Journal of Endocrinology (1990) 126, 159–168


2009 ◽  
Vol 15 ◽  
pp. 232-234 ◽  
Author(s):  
E.M Mendes do Nascimento ◽  
S. Colombo ◽  
T.K. Nagasse-Sugahara ◽  
R.N. Angerami ◽  
M.R. Resende ◽  
...  

2016 ◽  
Vol 129 ◽  
pp. 205-212 ◽  
Author(s):  
Adrian Marcelo Granero ◽  
Gastón Darío Pierini ◽  
Sebastián Noel Robledo ◽  
María Susana Di Nezio ◽  
Héctor Fernández ◽  
...  

mSphere ◽  
2018 ◽  
Vol 3 (6) ◽  
Author(s):  
Gregory R. Wiedman ◽  
Yanan Zhao ◽  
David S. Perlin

ABSTRACT Clinicians need a better way to accurately monitor the concentration of antimicrobials in patient samples. In this report, we describe a novel, low-sample-volume method to monitor the azole-class antifungal drug posaconazole, as well as certain other long-chain azole-class antifungal drugs in human serum samples. Posaconazole represents an important target for therapeutic drug monitoring (TDM) due to its widespread use in treating invasive fungal infections and well-recognized variability of pharmacokinetics. The current “gold standard” requires trough and peak monitoring through high-pressure liquid chromatography (HPLC) or liquid chromatography-tandem mass spectroscopy (LC-MS/MS). Other methods include bioassays that use highly susceptible strains of fungi in culture plates or 96-well formats to monitor concentrations. Currently, no method exists that is both highly accurate in detecting free drug concentrations and is also rapid. Herein, we describe a new method using reduced graphene oxide (rGO) and a fluorescently labeled aptamer, which can accurately assess clinically relevant concentrations of posaconazole and other long-chain azole-class drugs in little more than 1 h in a total volume of 100 µl. IMPORTANCE This work describes an effective assay for TDM of long-chain azole-class antifungal drugs that can be used in diluted human serum samples. This assay will provide a quick, cost-effective method for monitoring concentrations of drugs such as posaconazole that exhibit well-documented pharmacokinetic variability. Our rGO-aptamer assay has the potential to improve health care for those struggling to treat fungal infections in rural or resource-limited setting.


2016 ◽  
Vol 8 (2) ◽  
pp. 249-255 ◽  
Author(s):  
B. L'Homme ◽  
J.-F. Focant

Human exposure to POPs is of concern and typical biomonitoring studies require large amounts of blood (5–75 mL) from participants. As a proof of concept, we developed a miniaturized method based on MEPS and CZC applied to GC-HRTOFMS for the measurement of markers of exposure (PCB-153, DDE) in 20 μL human serum samples.


Sign in / Sign up

Export Citation Format

Share Document