scholarly journals Complementary Use of APFIM and TEM for a Study of Precipitation in a Rapidly Solidified Stainless Steel

1997 ◽  
Vol 3 (S2) ◽  
pp. 683-684
Author(s):  
T. F. Kelly ◽  
S. Wisutmethangoon ◽  
P. P. Camus ◽  
D. J. Larson ◽  
M. K. Miller

Stainless steels are important technologically for a wide range of applications. Though they are attractive for their environmental stability, austenitic versions of these steels are not generally known for their very high strength. We have rapid-solidification-processed many stainless steels by gas atomization and achieved strength improvements of over 50% relative to conventionally-processed stainless steels with concomitant improvement in corrosion and oxidation behavior. These strength improvements are most pronounced when elevated concentrations of oxygen and vanadium are present in the metal and we need to know how these elements affect precipitation in the alloy.The specimen material (FCC Fe-16%Ni-9%Cr-0.5%Mn-0.2%V-0.0137%N-0.008%O by weight) was prepared by gas atomization and hot extrusion followed by precipitation aging as described elsewhere. We observed the structure in TEM and found 20 nm precipitates on dislocations, Fig. 1a. We did not observe smaller precipitates in the grain interiors using diffraction contrast bright field imaging, however, with weak-beam dark field imaging, Moiré fringe contrast is observed throughout the material, Fig. 1b.

1997 ◽  
Vol 3 (S2) ◽  
pp. 981-982
Author(s):  
S. Wisutmethangoon ◽  
T.F. Kelly ◽  
P.P. Camus ◽  
J.E. Flinn ◽  
D.J. Larson ◽  
...  

Though stainless steels are important technologically for a wide range of applications, they are not generally known for their very high strength. We have rapid-solidification-processed many stainless steels by gas atomization and achieved strength improvements of over 50% relative to conventionally-processed stainless steels with concomitant improvement in corrosion and oxidation behavior. These strength improvements are most pronounced after aging treatments when elevated concentrations of oxygen and vanadium are present in the stainless steel. An austenitic (FCC) stainless steel (Fe-16%Ni-9%Cr-0.5%Mn-0.2%V-0.0137%N-0.008%O by weight) was prepared by gas atomization and consolidated by hot extrusion at 900°C. These specimens were heat treated for 1 hour at 1000°C and aged at 600°C for 500 hours.The microstructure of each alloy composition was observed in TEM with bright field imaging. After aging, most alloys showed the same precipitate morphology as before aging. An obvious change, however, was found only in the alloy with highest oxygen content.


Author(s):  
M. Awaji

It is necessary to improve the resolution, brightness and signal-to-noise ratio(s/n) for the detection and identification of point defects in crystals. In order to observe point defects, multi-beam dark-field imaging is one of the useful methods. Though this method can improve resolution and brightness compared with dark-field imaging by diffuse scattering, the problem of s/n still exists. In order to improve the exposure time due to the low intensity of the dark-field image and the low resolution, we discuss in this paper the bright-field high-resolution image and the corresponding subtracted image with reference to a changing noise level, and examine the possibility for in-situ observation, identification and detection of the movement of a point defect produced in the early stage of damage process by high energy electron bombardment.The high-resolution image contrast of a silicon single crystal in the [10] orientation containing a triple divacancy cluster is calculated using the Cowley-Moodie dynamical theory and for a changing gaussian noise level. This divacancy model was deduced from experimental results obtained by electron spin resonance. The calculation condition was for the lMeV Berkeley ARM operated at 800KeV.


Author(s):  
S. Wisutmethangoon ◽  
T. F. Kelly ◽  
J.E. Flinn

Vacancies are introduced into the crystal phase during quenching of rapid solidified materials. Cavity formation occurs because of the coalescence of the vacancies into a cluster. However, because of the high mobility of vacancies at high temperature, most of them will diffuse back into the liquid phase, and some will be lost to defects such as dislocations. Oxygen is known to stabilize cavities by decreasing the surface energy through a chemisorption process. These stabilized cavities, furthermore, act as effective nucleation sites for precipitates to form during aging. Four different types of powders with different oxygen contents were prepared by gas atomization processing. The atomized powders were then consolidated by hot extrusion at 900 °C with an extrusion ratio 10,5:1. After consolidation, specimens were heat treated at 1000 °C for 1 hr followed by water quenching. Finally, the specimens were aged at 600 °C for about 800 hrs. TEM samples were prepared from the gripends of tensile specimens of both unaged and aged alloys.


Author(s):  
P. Xu ◽  
E. J. Kirkland ◽  
J. Silcox

Many studies of thin metal film growth and the formation of metal-semiconductor contacts have been performed using a wide range of experimental methods. STEM annular dark field imaging could be an important complement since it may allow direct imaging of a single heavy atom on a thin silicon substrate. This would enable studies of the local atomic arrangements and defects in the initial stage of metal silicide formation.Preliminary experiments were performed in an ultra-high vacuum VG HB501A STEM with a base pressure of 1 × 10-10 mbar. An antechamber directly attached to the microscope for specimen preparation has a base pressure of 2×l0-10 mbar. A thin single crystal membrane was fabricated by anodic etching and subsequent reactive etching. The specimen was cleaned by the Shiraki method and had a very thin oxide layer left on the surface. 5 Å of gold was deposited on the specimen at room temperature from a tungsten filament coil monitored by a quartz crystal monitor.


2021 ◽  
Vol 135 ◽  
pp. 104145
Author(s):  
Yani P. Latul ◽  
Arnoud W. Kastelein ◽  
Patricia W.T. Beemster ◽  
Nienke E. van Trommel ◽  
Can Ince ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Andreas P. Sauter ◽  
Jana Andrejewski ◽  
Manuela Frank ◽  
Konstantin Willer ◽  
Julia Herzen ◽  
...  

AbstractGrating-based X-ray dark-field imaging is a novel imaging modality with enormous technical progress during the last years. It enables the detection of microstructure impairment as in the healthy lung a strong dark-field signal is present due to the high number of air-tissue interfaces. Using the experience from setups for animal imaging, first studies with a human cadaver could be performed recently. Subsequently, the first dark-field scanner for in-vivo chest imaging of humans was developed. In the current study, the optimal tube voltage for dark-field radiography of the thorax in this setup was examined using an anthropomorphic chest phantom. Tube voltages of 50–125 kVp were used while maintaining a constant dose-area-product. The resulting dark-field and attenuation radiographs were evaluated in a reader study as well as objectively in terms of contrast-to-noise ratio and signal strength. We found that the optimum tube voltage for dark-field imaging is 70 kVp as here the most favorable combination of image quality, signal strength, and sharpness is present. At this voltage, a high image quality was perceived in the reader study also for attenuation radiographs, which should be sufficient for routine imaging. The results of this study are fundamental for upcoming patient studies with living humans.


2001 ◽  
Vol 7 (S2) ◽  
pp. 344-345
Author(s):  
G. Möbus ◽  
R.E. Dunin-Borkowski ◽  
C.J.D. Hethėrington ◽  
J.L. Hutchison

Introduction:Atomically resolved chemical analysis using techniques such as electron energy loss spectroscopy and annular dark field imaging relies on the ability to form a well-characterised sub-nm electron beam in a FEGTEM/STEM [1-2]. to understand EELS+EDX-signal formation upon propagation of a sub-nm beam through materials we first have to assess precisely the beam intensity distribution in vacuum and find conditions for the best obtainable resolution.Experimental Details:Modern TEM/STEM instruments combine features of both imaging and scanning technology. The beam forming capability approaches closely that for dedicated STEMs, while CCD recording devices allow us to measure the beam profile by direct imaging at magnifications up to 1.5 M. The recording of a “z-section” series through the 3D intensity distribution of the cross-over can therefore be realised by recording of a “condenser focal series”.